KEY–feed
pump A
1*
3*
16*
A
B
2*
4*
17*
KEY–
feed
pump B
Light KEY
1*
Constant Green: Feed pump A on.
2*
Constant Green: Feed pump B on.
3*
Blinking Green: Pressure of inlet A displayed
Red: Low pressure A alarm
4*
Blinking Green: Pressure of inlet B displayed
Red: Low pressure B alarm
5*
Constant Green: Material A filled to full level sensor
Off: Material A is below full level sensor
Red: Full level sensor A alarm in Spray Mode
6*
Constant Green: Material A filled to low level sensor
Off : Material A is below low level sensor in Manual Mode
Red: Material A supply low alarm in Spray Mode
7*
Constant Green: Material B filled to full level sensor
Off: Material B is below full level sensor
Red: Full level sensor B alarm in Spray Mode
8*
Constant Green: Material B filled to low level sensor
Off : Material B is below low level sensor in Manual Mode
Red: Material B supply low alarm in Spray Mode
9
Constant Green: Premier pump on
Red: Runaway pump alarm
*Will not function in basic units unless sensors are used to monitor other areas.
Fig. 19
26
308925
Control Overview
5*
6*
9
A
B
8*
7*
10
KEY–Premier pump
A
11
12
10
Blinking Green: Volume of Material A usage displayed
11
Blinking Green: Volume of Material B usage displayed
10 & 11 Both Blinking Green: Volume of Material A and B usage
displayed
12
Blinking Green: High pressure A displayed
13
Blinking Green: High pressure B displayed
12 & 13 Both Blinking Green: Pressure differential between A and B
pump lower displayed
Red: Pressure differential alarm in Spray Mode
14
Blinking Green: Remaining material work life displayed
Red: Material work life alarm
15
Constant Green: Solvent pump on.
Blinking Green: Solvent pump usage displayed.
Red: Solvent pump run away alarm
16* Constant Green: Material A is within temperature range.
Blinking Green: Material A is at indicated temperature.
Red: Material A is outside temperature range.
17* Constant Green: Material B is within temperature range.
Blinking Green: Material B is at indicated temperature.
Red: Material B is outside temperature range.
KEY–
solvent pump
A/B
S
A
A/B S
B
A
B
AB
B
13
14
15

Advertisement

Table of Contents
loading

Table of Contents