Connecting The Eps-500 Power Supply - Extreme Networks Summit X450a-24tDC Hardware Installation Manual

Extremexos summit family switches summit x150 series summit x250e series summit x350 series summit x450 series summit x450a series summit x450e series
Hide thumbs Also See for Summit X450a-24tDC:
Table of Contents

Advertisement

Figure 68: Attaching a Mounting Bracket
c Repeat steps
a
and
4 Slide the EPS-500 into a 19-inch rack and secure it using appropriate rack-mount screws.I
NOTE
Extreme Networks recommends that you position the EPS-500 so that the output connectors are on the same
side as the external connector on the connecting switch. If you position the EPS-500 with the connectors facing
in the opposite direction from the Summit switch connector, leave at least 1 u between the switch and the EPS-
500 through which to slide the power cords. Do not route the power cords around the equipment rack.

Connecting the EPS-500 Power Supply

CAUTION
Do not attach the AC power cord to the EPS-500 unit until the unit is properly grounded at the electrical outlet and
the redundant power cord is connected.
One end of the EPS-500 cord has a keyed connector to ensure correct alignment of the connector
(Figure
69). The key is a plastic tab on the connector housing that fits into the EPS-500 unit to ensure
correct alignment of the connector.
Figure 69: EPS-500 Redundant Power Cord with Connector Key
1 Connect the keyed end of the EPS-500 redundant power cord to the power supply unit (see
Figure
70).
2 Connect the other end of the redundant power cord to the Extreme switch.
The connector fits the slot in only one direction.
Summit Family Switches Hardware Installation Guide
b
on the opposite side of the EPS-500.
Installing an EPS-500 External Power Supply Unit
Collin's
ES4K026
XM_073
Collin's
ES4K027
XM_055