Connecting The Eps-Ld To The Switch - Extreme Networks Summit X450a-24tDC Hardware Installation Manual

Extremexos summit family switches summit x150 series summit x250e series summit x350 series summit x450 series summit x450a series summit x450e series
Hide thumbs Also See for Summit X450a-24tDC:
Table of Contents

Advertisement

Installing Summit External Power Supplies
Figure 65: Attaching the Mounting Bracket
c Repeat steps
4 Slide the EPS-LD into a 19-inch rack and secure it using appropriate rack-mount screws.
NOTE
Extreme Networks recommends that you position the EPS-LD so that the output connectors are on the same side
as the external connector on the connecting switch. If you mount the EPS-LD with the connectors facing in the
opposite direction from the Summit switch connector, leave at least 1 U between the switch and the EPS-LD
through which to slide the power cords. Do not route the power cords around the equipment rack.

Connecting the EPS-LD to the Switch

CAUTION
Do not attach the AC power cord to the EPS-LD unit until the unit is properly grounded at the electrical outlet and
the redundant power supply cord is connected.
One end of the EPS-LD cord has a keyed connector to ensure correct alignment of the connector
(Figure
66). The key is a plastic tab on the cord connector housing that fits into the EPS-LD unit to
ensure correct alignment of the connector.
Figure 66: EPS-LD Cord with Key
To connect the EPS-LD to the switch:
1 Connect the keyed end of the cord to the power supply unit (see
2 Align and tighten the captive retaining screws on the connector.
3 Connect the other end of the EPS-LD cord to the Extreme switch.
The connector fits in only one direction.
100
a
and
b
for the other side of the EPS-LD unit.
Collin's
ES4K026
XM_054
Collin's
ES4K027
XM_055
Figure
67).
Summit Family Switches Hardware Installation Guide