5.1.10 Output test
For a proper fault analysis a diagnoses should be made first.
The output test gives an overview of all parts able to deliver signals (electrical components).
Components that can be tested:
• buzzer
• canister(s)
► Despite the fact that sufficient safety measures are taken working with the systems may entail
risks. Our starting point is that people activating this menu are sufficiently skilled and therefore
able to properly assess these risks with respect to safety.
5.1.10 
5.1.10a 
5.1.10b 
• mixer motor
• low pressure pump
Output test
• press "output test" to confirm
► There are two options for testing:
» Pulse: the action is executed as long as the button is
pressed.
» Cycle: the action is executed for 10 seconds and press on
to interrupt.
cancel
• press or to scroll through the maintenance menu
Buzzer test:
• press
,
pulse
result: short 'beep'
• press
,
cycle
result: multiple short 'beeps'
• press or to select another component
Canister motor test Bolero 1:
• remove the canister
• press
,
pulse
result: the canister motor runs briefly at 20% speed
• press
,
cycle
result: the canister motor runs at 20% speed for 10 seconds
• press or to select another component
• heating element
• magnetic inlet valve
• fan motor