5.1.10c
5.1.10d
5.1.10e
5.1.10f
42
Canister motor test Bolero 2:
• press
to select a canister in the next screen
test
• press or to select another component
Canister motor test Bolero 2:
• remove the canister(s)
• press
,
pulse
result: the canister motor runs briefly at 20% speed
• press
,
cycle
result: the canister motor runs at 20% speed for 10 seconds
• press or to select another canister
Mixer motor test:
• press
,
pulse
result: the mixer motor runs briefly at full speed
• press
,
cycle
result: the mixer motor runs at full speed for 10 seconds
• press or to select another mixer
Low pressure pump test:
• press
,
pulse
result: the pump motor runs briefly
• press
,
cycle
result: the pump motor runs for 10 seconds
► The water will not reach the mixing system.
• press or to select another component