5.1.10 Output test
For a proper fault analysis a diagnoses should be made first.
The output test gives an overview of all parts able to deliver signals (electrical components).
Components that can be tested:
• buzzer
• canister motor
► Despite the fact that sufficient safety measures are taken working with the systems may entail
risks. Our starting point is that people activating this menu are sufficiently skilled and therefore
able to properly assess these risks with respect to safety.
5.1.10
5.1.10a
5.1.10b
44
• mixer motor
• low pressure pump • magnetic inlet valve
• heating element
Output test
• press "output test" to confirm
► There are two options for testing:
» pulse: the action is executed as long as
the button is pressed.
» cycle: the action is executed for 10
seconds and press on
• press or to scroll through the
maintenance menu
Buzzer test:
• press
,
pulse
result: short 'beep'
• press
,
cycle
result: multiple short 'beeps'
• press or to select another component
Canister motor test:
• press
to select a canister in the next
test
screen
► The number of canisters may vary per
configuration, see §7.3 on p.128.
• press or to select another component
• fan motor
• water selector motor
to interrupt.
cancel