Configure The Drive; Set The Network Parameters; Studio 5000 Logix Designer - Allen-Bradley Kinetix 5500 User Manual

Hide thumbs Also See for Kinetix 5500:
Table of Contents

Advertisement

Chapter 6
Configure and Start the Kinetix 5500 Drive System

Configure the Drive

Studio 5000 Logix Designer

106
You can include the drive in your Logix Designer application by adding it to a
configured EtherNet/IP module or controller and adding it under the
I/O configuration tree. After setting network parameters, you can view the drive
status information in Studio 5000 software and use it in your Logix Designer
application.

Set the Network Parameters

You must program network parameters by using the LCD display.
1. From the LCD display, select SETUP>NETWORK and choose between
STATIC IP and DHCP.
The default setting is STATIC IP.
2. If STATIC IP, then press
• IP address
• Gateway
• Subnet mask
Settings are stored in nonvolatile memory. IP addressing can also be changed
through the Module Configuration dialog box in RSLinx® software. Changes to
the IP addressing take effect after power is cycled. The drive is factory
programmed to static IP address of 192.168.1.1.
Refer to
Setup Screens
For help using the Studio 5000 Logix Designer application as it applies to
configuring the ControlLogix or CompactLogix controllers, refer to
Resources
on
page
11.
Rockwell Automation Publication 2198-UM001F-EN-P - December 2015
to configure the following parameters:
on
page 104
for help setting the network parameters.
Additional

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF