en | Programming and Operating the AMAX System
Menu Items
5 SYSTEM MANAGER
SYSTEM SETTING 1
SYSTEM SETTING 2
SYSTEM VIEW
FACTORY DEFAULT
Figure 5.14: System Manager
2015.05 | 05 | F.01U.309.297
All manuals and user guides at all-guides.com
Parameters / Description
DATE/TIME
FAULT CONFIG
FAULT SOUND REMIND
0-disable 1-enable
AC FAULT DELAY T.
0-98 min 99=disable
DATE / TIME FAULT
0-disable 1-enable
BATT. CHK INTERVAL
00 = disabled 01 - 15 minutes
PHO. LN SUPERVISED
0-disable 1-enable
SIREN SUPERVISED
AC FAULT AUTO RST
0-disable 1-enable
COM FAULT AUTO RST
0-disable 1-enable
PHONE FLT AUTO RST
0-disable 1-enable
GEN FAULT AUTO RST
0-disable 1-enable
QUICK ARM ONLY */#
0-disable 1-enable
INSTALLER ACCESS
0-disable 1-enable
FORCE ARM FAULT/TA
0-disable 1-enable
EVENT RECORD COUNT
3 - 10 Record count of same event per armed period
1-EN 6-PL 9-TR
LANGUAGE VERSION
2-DE 4-FR 5-PT 7NL
1-EN 3-ES 6-PL 8SE
KP 2 BUTTON ALARM
0-disable 1-enable
SYS TAMPER INDIC.
SYS TAMP. ALL AR.
0 = area1 1 = all areas
DEOL TAMP. BYPASS
0-disable 1-enable
ENCL TAMP. TIMING
1 - 9999 x100ms
AREA NAME
COMPANY NAME
DEFAULT VOICE YES
VOICE MEM. DEFAULT
DEFAULT VOICE NO
FAULT ANALYSIS
FW VERSION
DEFAULT PANEL YES
FACTORY DEFAULT
DEFAULT PANEL NO
DEFAULT OPTION
FACT. DEF. ENABLE
0-disable 1-enable
Quick Start Manual
0-disabled
1-po-1
enabled
2-po-2
enabled
3-po-1+2 enabled
AMAX panel
Certification
Default
1
60
EN=1
0
EN=15
15
EN=1
0
EN=3
0
EN=1
0
EN=1
0
EN=1
0
EN=1
0
EN=0
1
0
EN=0
1
EN=3-10
10
EN=0
1
3
Bosch Sicherheitssysteme GmbH