Komatsu PC290LC-11 Operation & Maintenance Manual page 182

Hydraulic excavator
Hide thumbs Also See for PC290LC-11:
Table of Contents

Advertisement

EXPLANATION OF COMPONENTS
Battery disconnect switch (1) is used for cutting out the electric-
ity from the battery.
This switch is installed inside the cover on the left side of the
machine.
Raise rubber cover (2), and the switch is seen.
REMARK
Operate this switch while system operating lamp (3) is OFF.
(O): OFF position
Switch key (1) can be pulled out (and inserted) and the current
from the battery is cut out.
(I): ON position
The current from the battery flows into the circuit.
Before starting the machine, be sure to set the switch to this
position.
SYSTEM OPERATING LAMP
System operating lamp (1) indicates that the controller mount-
ed on the machine is turned ON.
System operating lamp (1) lights up in green when the control-
ler is turned ON and goes out in 1 to 5 minutes after the start-
ing switch is turned to OFF position.
Before operating the battery disconnect switch, check that sys-
tem operating lamp (1) is turned OFF.
NOTICE
If the battery disconnect switch is turned OFF while this
lamp is lit, the data in the controller may be lost.
REMARK
Even if the starting switch is in OFF position, the controller may operate. The lamp lights up in this case, but
it does not indicate abnormality.
After the starting switch has been turned off, the system operating lamp may stay lit for a long time.
In such case, consult your Komatsu distributor.
3-110
OPERATION

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc290nlc-11

Table of Contents