Download Print this page

netvox R720FLD User Manual

Wireless liquid hand soap sensor/ wireless water leak detector

Advertisement

Quick Links

R720FLD / R720FLO / R720FU : Wireless Liquid Hand Soap Sensor
R720FW : Wireless Water Leak Detector
Wireless Liquid Hand Soap Sensor/
Wireless Water Leak Detector
Copyright©Netvox Technology Co., Ltd.
This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in
strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX
Technology. The specifications are subject to change without prior notice.
R720F Series
User Manual
Model:R720F Series

Advertisement

loading
Need help?

Need help?

Do you have a question about the R720FLD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for netvox R720FLD

  • Page 1 This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The specifications are subject to change without prior notice.
  • Page 2: Table Of Contents

    Table of Content 1. Introduction ....................2 2. Appearance ....................3 3. Main Features ..................... 5 4. Set up Instruction ..................6 5. Data Report ....................7 6. Installation ....................11 7. Information about Battery Passivation ............ 12 8. Important Maintenance Instruction ............13...
  • Page 3: Introduction

    The hand wash detection devices are R720FLO,R720FLD,R720FU. The devices are connected with two electrode rods. The shape and orientation of electrode rod of can be selected according to the needs, and the electrode rode can be trimmed to the required length by self according to the demand.
  • Page 4: Appearance

    2. Appearance Hand Wash Detection Electrode Rod Indicator Function Key R720FLO L-type Probe- Electrode rods Upward R720FLD L-type Probe- Electrode rods Downward...
  • Page 5 R718FU U-type Probe Water Leakage Detection: R720W...
  • Page 6: Main Features

     Applicable to third-party platforms: Actility / ThingPark, TTN, MyDevices/Cayenne  Low power consumption and long battery life Note: Battery life is determined by the sensor reporting frequency and other variables, please refer to http://www.netvox.com.tw/electric/electric_calc.html On this website, users can find battery lifetime for varied models at different configurations.
  • Page 7: Set Up Instruction

    4.Set up Instruction On/Off Power On Insert batteries. (users may need a screwdriver to open) Turn On Press and hold the function key for 3 seconds till the green indicator flashes once. Turn Off (Restore to factory setting) Press and hold the function key for 5 seconds and the green indicator flashes 20 times. Power Off Remove Batteries 1.
  • Page 8: Data Report

    1. The cycle of the device sending the data report is according to the default. 2. The interval between two reports must be the MinTime. The device reported data parsing please refer to Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver http://loraresolver.netvoxcloud.com:8888/page/index...
  • Page 9 Example of ConfigureCmd FPort:0x07 Bytes Var(Fix =9 Bytes) CmdID DeviceType NetvoxPayLoadData CmdID– 1 byte DeviceType– 1 byte – Device Type of Device NetvoxPayLoadData– var bytes (Max=9bytes) Device Description Device NetvoxPayLoadData Type ConfigReport 0x01 MinTime MaxTime BatteryChange Reserved (2bytes Unit: s) (2bytes Unit: s) (1byte Unit: 0.1v) (4Bytes, Fixed 0x00)
  • Page 10 Version– 1 bytes –0x01——the Version of NetvoxLoRaWAN Application Command Version DeviceType– 1 byte – Device Type of Device The devicetype is listed in Netvox LoRaWAN Application Devicetype doc ReportType – 1 byte –the presentation of the NetvoxPayLoadData,according the devicetype NetvoxPayLoadData– Fixed bytes (Fixed =8bytes)
  • Page 11 MaxTime Sleeping(MinTime) sleeping sleeping sleeping Wakes up and Wakes up and Wakes up and Wakes up and Wakes up and collects data collects data collects data collects data collects data REPORT 3.6V 3.6V 3.6V 3.6V REPORTS 3.6V Does not report Does not report Does not report Example#3 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e.
  • Page 12: Installation

    1.The device can be fixed on the cover by the force rubber, or make the hole in the cover and bundle the device with cable ties. 2. The length of the probe can be trimmed according to personal requirements. 3. When the level of the hand wash is lower than electrode rods, the device will issue a warning. R720FLD R720FLO R720FU...
  • Page 13: Information About Battery Passivation

    (if using an electric screwdriver, it is recommended to set the torque as 4kgf) to ensure the device is impermeable. 7. Information about Battery Passivation Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many advantages including low self-discharge rate and high energy density.
  • Page 14: Important Maintenance Instruction

    8. Important Maintenance Instruction The device is a product with superior design and craftsmanship and should be used with care. The following suggestions will help you use the warranty service effectively. • Keep the equipment dry. Rain, moisture and various liquids or water may contain minerals that can corrode electronic circuits.

This manual is also suitable for:

R720f seriesR720floR720fuR720fw