Kirby Morgan KMB 18 Quick Start Manual page 4

Daily mask and emergency gas system set-up and functional checklists
Hide thumbs Also See for KMB 18:

Advertisement

STEP
3. EGS Inspection
4. Check the Mask
5. Attach the
Umbilical
Kirby Morgan, SuperLite, Band Mask, KMB Band Mask, EXO, SuperMask, SuperFlow, and Rex are all registered trademarks of
Kirby Morgan Dive Systems, Inc. Use of these terms to describe products that are not manufactured by KMDSI is not permitted without
written permission from KMDSI.
© Copyright 1970-2017 Kirby Morgan Dive Systems, Inc. All rights reserved. KMDSI manuals, checklists and technical and training
information is made available for the express use of owner/user of this Kirby Morgan products. No part of this material may be reproduced,
stored in any retrieval system, or transmitted, or used in any form or by any means, whether graphic, electronic, mechanical, photocopy, or
otherwise by technology known or unknown, without the prior written permission of Kirby Morgan Dive Systems, Inc
PROCEDURES
Diver/Tender: Check the following (a-e):
a. Visually inspect all EGS hoses for signs of
damage.
b. Check to ensure the cylinder is within the VIP
and the hydro dates.
c. Ensure the First Stage Regulator pressure
setting and the Over Pressure Bleed/Relief
Valve settings have been checked within the
past month. (Maintenance Log).
d. Inspect the Safety Harness and Cylinder
Retainer for wear and damage.
Repair/replace as necessary.
e. Document inspection/maintenance in
Maintenance Log (Appendix 3).
Diver/Tender: Check the following (a-d):
a. Rotate the Regulator Adjustment Knob in
fully (clockwise), then rotate out
(counterclockwise) 3 – 4 rotations to check
for smooth operation.
b. Open the EGS Supply Valve on the cylinder.
Log the pressure _______ psig. Then open
the Emergency Supply Valve on the Side
Block.
c. Momentarily open the Mask Defogger/Steady
Flow Valve ¾ to 1 full turn. Check for a
strong flow of gas out of the Defogging Train,
and then close.
d. Check for gas escaping from the One Way
Valve.
Tender:
Blow down the Umbilical and attach it to the
Umbilical Adapter on the One Way Valve.
Diver/Tender: Check the following (a-d):
Copyright 2003-2017, Dive Lab®., Inc. All rights reserved. TechTrnG 03101
INITIALS

Advertisement

loading

This manual is also suitable for:

Kmb 28