Download Print this page

Kirby Morgan KMB 18 Quick Start Manual page 2

Daily mask and emergency gas system set-up and functional checklists
Hide thumbs Also See for KMB 18:

Advertisement

STEP
1. Hood and Band
Assembly
NOTE: When the
screws that
hold the
Bands in
position are
properly
torque, the
Hood and
Face Seal
cannot be
removed
from frame.
2. Visually Inspect
Mask
NOTE: KMDSI
recommends
replacement
of the Hose
Assembly
(117a) on the
Kirby Morgan, SuperLite, Band Mask, KMB Band Mask, EXO, SuperMask, SuperFlow, and Rex are all registered trademarks of
Kirby Morgan Dive Systems, Inc. Use of these terms to describe products that are not manufactured by KMDSI is not permitted without
written permission from KMDSI.
© Copyright 1970-2017 Kirby Morgan Dive Systems, Inc. All rights reserved. KMDSI manuals, checklists and technical and training
information is made available for the express use of owner/user of this Kirby Morgan products. No part of this material may be reproduced,
stored in any retrieval system, or transmitted, or used in any form or by any means, whether graphic, electronic, mechanical, photocopy, or
otherwise by technology known or unknown, without the prior written permission of Kirby Morgan Dive Systems, Inc
PROCEDURES
Diver/Tender: Check the following (a-d):
a. Visually inspect the Hood and Face Seal for
signs of damage. Check the Hood for tears,
holes, and/or cuts. Ensure the Face Seal is
properly glued to the Hood.
b. Check the screws that hold the Bands in
position. They must be properly torque to 26
inch pounds (28 kg cm).* Guidance Modular
O & M Manual.
NOTE: Maximum torque, bands should have no
less than an 1/8 inch (3mm) even gap
between the bands. On installation , a marine
grade anti-seize may be used on this screw.
The screws may need adjustment after several
dives.
c. Inspect the Bands. Ensure the welds exhibit
no signs of cracking and/or parting. Inspect
all band keeper components
DANGER: If the Bands become loose, the Hood
and Face Seal could separate from the Mask.
This would cause the Mask to flood, which
could cause drowning.
d. Inspect the Head Harness/Spider to ensure
there are no tears and/or cracks in the material.
Ensure all five legs are present. If it is worn
and/or cracked, it must be replaced.
e. Ensure band keepers are installed and properly
torqued, Guidance Modular O & M Manual.
Diver/Tender: Check the following (a-g):
a. Visually inspect the interior/exterior of the
Band Mask for any obvious signs of damage.
Check to make sure the Oral Nasal Valve is
correctly installed and the Oral Nasal Mask is
installed on the Regulator Mount Nut
properly. Ensure the Nose Clearing Device
operates smoothly. Lubricate as necessary.
Guidance Modular O & M Manual.