Daikin Altherma 3 H MT F Installer's Reference Manual page 267

Hide thumbs Also See for Altherma 3 H MT F:
Table of Contents

Advertisement

6/12
Field settings table
Breadcrumb
Field code
Setting name
9.2.2
[D-02]
DHW pump
9.2.4
[D-07]
Solar
└─ Back up heater
9.3.1
[E-03]
BUH type
9.3.2
[5-0D]
Voltage
9.3.3
[4-0A]
Configuration
9.3.4
[6-03]
Capacity step 1
9.3.5
[6-04]
Additional capacity step 2
9.3.6
[5-00]
Equilibrium: Deactivate backup heater (or external backup heat source in case of a
bivalent system) above the equilibrium temperature for space heating?
9.3.7
[5-01]
Equilibrium temperature
9.3.8
[4-00]
Operation
└─ Booster heater
9.4.1
[6-02]
Capacity
9.4.3
[8-03]
BSH eco timer
9.4.4
[4-03]
Operation
└─ Emergency
9.5
[4-06]
Emergency
9.5.2
[7-06]
Compressor forced OFF
└─ Balancing
9.6.1
[5-02]
Space heating priority
9.6.2
[5-03]
Priority temperature
9.6.3
[5-04]
Offset BSH setpoint
9.6.4
[8-02]
Anti-recycle timer
9.6.5
[8-00]
Minimum running timer
9.6.6
[8-01]
Maximum running timer
9.6.7
[8-04]
Additional timer
Installer settings
9.7
[4-04]
Water pipe freeze prevention
└─ Benefit kWh power supply
9.8.2
[D-00]
Allow heater
9.8.3
[D-05]
Allow pump
9.8.4
[D-01]
Benefit kWh power supply
9.8.6
Allow electric heaters
9.8.7
Enable Room buffering
9.8.8
Limit setting kW
└─ Power consumption control
9.9.1
[4-08]
Power consumption control
9.9.2
[4-09]
Type
9.9.3
[5-05]
Limit
9.9.4
[5-05]
Limit 1
9.9.5
[5-06]
Limit 2
9.9.6
[5-07]
Limit 3
9.9.7
[5-08]
Limit 4
4P634892-1 - 2021.03
Range, step
Default value
R/W
0: No DHW pump
1: Instant hot water
2: Disinfection
3: Circulation
4: Circulation and disinfection
RO
0: No
1: Yes
R/O
3: 6V (*1)
4: 9W (*2)
R/W (*1)
0: 230V, 1~ (*1)
R/O (*2)
1: 230V, 3~ (*1)
2: 400V, 3~ (*2)
R/W
1: 1/1+2 (*1) (*2)
2: 1/2
3: 1/2 + 1/1+2 in emergency
R/W
0~10kW, step: 0,2kW
2kW (*1)
3kW (*2)
R/W
0~10kW, step: 0,2kW
4kW (*1)
6kW (*2)
R/W
0: No
1: Yes
R/W
-15~35°C, step: 1°C
0°C
R/W
0: Disabled
1: Enabled
2: Only DHW
R/W
0~10kW, step: 0,2kW
0kW
R/W
20~95 min, step: 5 min
50 min
R/W
0: Restricted
1: Allowed
2: Overlap
3: Compressor off
4: Legionella only
R/W
0: Manual
1: Automatic
2: Auto red SH/ DHW ON
3: Auto red SH/ DHW OFF
4: Auto normal SH/ DHW OFF
R/W
0: Disabled
1: Enabled
R/W
0: Disabled
1: Enabled
R/W
-15~35°C, step: 1°C
0°C
R/W
0~20°C, step: 1°C
10°C
R/W
0~10 hour, step: 0,5 hour
0,5 hour
R/W
0~20 min, step: 1 min
1 min
R/W
5~95 min, step: 5 min
30 min
R/W
0~95 min, step: 5 min
95 min
[E-0D] =0
0: Continuous pump operation
R/O
1: Non continuous pump operation
[E-0D] =1
2: OFF
R/W
R/W
0: None
1: BSH only
2: BUH only
3: All heaters
R/W
0: Forced off
1: As normal
R/W
0: No
1: Active open
2: Active closed
3: Smart Grid
R/W
0: No
1: Yes
R/W
0: No
1: Yes
R/W
0~20 kW, step: 0,5 kW
2 kW
R/W
0: No limitation
1: Continuous
2: Digital inputs
R/W
0: Current
1: Power
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
Installer setting at variance with
default value
Date
Value
(*1) *6V_(*2) *9W_