Daikin Altherma 3 H MT F Installer's Reference Manual page 259

Hide thumbs Also See for Altherma 3 H MT F:
Table of Contents

Advertisement

Electrical connection diagram
For more details, please check the unit wiring.
POWER SUPPLY
Only for normal power supply installation
1
Unit power supply:
400 V or 230 V + earth
1
Only for preferential kWh rate power supply installation
Unit preferential kWh rate power supply:
400 V or 230 V + earth
Normal kWh rate power supply for indoor unit:
230 V
FIELD SUPPLY
2
Preferential kWh rate power supply contact
Only for low voltage Smart Grid
2
Smart Grid contact S10S
OPTIONAL PART
2
Only for high voltage Smart Grid
Smart Grid contact K1A
Smart Grid relay K1A
Smart Grid relay K2A
High voltage Smart Grid control supply: 230 V
FIELD SUPPLY
3
Safety thermostat Q4L
Backup heater power supply (6/9 kW):
400 V or 230 V + earth
(F1B)
OPTIONAL PART
WLAN module
A20P: J2
communication
FIELD SUPPLY
Safety thermostat Q3L
Power limitation demand input 1
Power limitation demand input 2
Power limitation demand input 3
Power limitation demand input 4
EPRA08~12EAV3+W1 + ETVZ12S18+23EA6V+9W
Daikin Altherma 3 H MT F
4P634887-1 – 2021.03
STANDARD PART
5 or 3 core
X1M: L-N-earth or
X1M: L1-L2-L3-N-earth
5 or 3 core
X1M: 1-2-3-earth
2 core
4 core
2 core
2×0.75
X1M: 1-2-3-earth
signal
X2M: 5-6
X5M: 9-10
2 core
2×0.75
X10M: 1-2
2 core
2×0.75
X10M: 3-4
4 core
X5M: 13
3
X5M: 14
2 core
X5M: 13-14
2×0.75
X6M: L1-L2-L3 + earth
5 or 4 or 3 core
or L-N + earth
or L1-L2-L3-N + earth
A11P: X5: 4-5
5 core
A11P: X9: 1-2-3
2 core
X5M: 1-2
signal
Only for *KRP1AHTA
2 core
A8P: X801M: 1-5
signal
2 core
A8P: X801M: 2-5
signal
2 core
A8P: X801M: 3-5
signal
2 core
A8P: X801M: 4-5
signal
OUTDOOR UNIT
INDOOR UNIT
A4P: Y1-YC
2 core
X2M: 7-9
Alarm output
230 V
A4P: X1-X2
2 core
Changeover to
ext. heat source output
signal
A4P: Y2-YC
2 core
X2M: 7-9
Cooling/heating
230 V
ON/OFF output
2 core
X2M: 1-2
230 V
2 core
NO valve: X2M: 21-28
NC valve: X2M: 21-29
230 V
2 core
X5M: 5-6
signal
2 core
X5M: 3-4
signal
2 core
X5M: 7-8
signal
External room thermostat / Heat pump convector
4
2 core
main: X2M: 30-35
add: X2M: 30-35a
signal
4
4 core
main: X2M: 30-31-35
add: X2M: 30-31-35a
signal
4
2 core
main: X2M: 30-35
add: X2M: 30-35a
signal
2 core
2×0.75
X5M: 11-12
communication
16
Notes:
- In case of signal cable: keep minimum distance to power cables >5 cm
Alarm indication
Ext. heat source (e.g. boiler)
Cooling/heating ON/OFF output
Circulation pump for domestic hot water
2-way valve
M2S for cooling mode
Electricity meter pulse input 1
Only for high voltage Smart Grid
Smart Grid contact K2A
Only for low voltage Smart Grid
Smart Grid contact S11S
Electricity meter pulse input 2
Smart Grid pulse meter
Only for KRCS01-1 or EKRSCA1
External thermistor (indoor or outdoor)
(main and/or additional zone)
Only for *KRTW (wired room thermostat)
A2P: X1M: com-H
Only for *KRTR (wireless room thermostat)
A15P: X1M: H-com
A2P: X1M: 1-3
X2M: L-N
Only for heat pump convector
A3P
Only for Human Comfort Interface
A14P: P1-P2 user interface
Technical data
|
FIELD SUPPLY
Only for *KRP1HB*
5
5
5
6
6
OPTIONAL PART
Only for *KRTETS
2 core
(3m included)
R2T External sensor (floor or
ambient)
signal
4D133017B
Installer reference guide
259

Advertisement

Table of Contents
loading

Table of Contents