Caution Statements................................................................................................................................................1
Composition of the Air-Conditioner ........................................................................................................................2
Special Remarks ....................................................................................................................................................3
.........................................................................................................................................................................................................................................................
1.Refrigerant Flow Diagram ................................................................................................................................. 4
2.Electrical Wiring Diagram ................................................................................................................................. 4
1. Safety Notice ....................................................................................................................................................5
2. The Tools and Instruments for Installation .........................................................................................................6
3. The Installation of the Indoor Unit .....................................................................................................................6
3.1 The Initial Check ..........................................................................................................................................6
3.2 Installation ....................................................................................................................................................7
4. Refrigerant Pipe ................................................................................................................................................9
4.1 The Pipe Material ........................................................................................................................................9
4.2 The Connection of the Pipe .........................................................................................................................9
5. Drain Piping......................................................................................................................................................
6. Electrical wiring ................................................................................................................................................11
6.1
General check ...........................................................................................................................................11
6.2 hange of Static Pressure ........................................................................................................................
C
7
. The Installation of the Outdoor Unit ................................................................................................................ 13
7.1 Installation Sites .........................................................................................................................................13
7.2 Installation of the Outdoor Unit ..................................................................................................................
8
. Refrigerant Tubing..........................................................................................................................................
8.1 Flaring with Tube Expander ...................................................................................................................... 14
8.2 Connecting Tubing between Indoor and Outdoor Units ............................................................................ 14
8.3 Heat Insulation of the Refrigerant Tube ....................................................................................................14
8.4 Taping the Tubes........................................................................................................................................14
8.5 Finishing the Installation ...........................................................................................................................14
9
. Air Purging and Test Run .................................................................................................................................14
9.1 Air Purging with a Vacuum Pump...............................................................................................................14
9.2 Leak Test....................................................................................................................................................15
9.3 Tidy Up the Tubing .....................................................................................................................................15
9.4 Test Run .....................................................................................................................................................15
9.5 Common.....................................................................................................................................................16
NOTE:●This heat pump air conditioner has been designed for the following temperatures.
Operate it within this range.
Series
DC-Inverter Unitary
Storage condition:
Alert Symbols:
DANGER
: The symbol refers to a hazard which can result in severe personal injury or death.
: The symbol refers to a hazard or an unsafe practice which may result in severe personal injury
WARNING
 
or death.
: The symbol refers to a hazard or an unsafe practice which may result in personal injury,
CAUTION
 
product or property damage.
NOTE
: It refers to the remarks and instruction to the operation, maintenance, and service.
Mode
Cooling Operation
Heatling Operation
Temperature -25~60℃
Humidity
30%~80%
Outdoor Working Temperature
Maximum(
℃)
Minimum(
℃)
48
-15
24
-15