Specification - XtremeAIR PX06-I42 Installation Manual & User Manual

Hide thumbs Also See for PX06-I42:
Table of Contents

Advertisement

9.
(9) Indicates the length of time left for delay off function.
10. (10) Lights up when auto-shutdown delay timer function is on.
A. ACTIVATING BLOWER FUNCTION:
 Option 1: Touch and hold down (+) for 1-2 seconds.
 Option 2: Touch and hold down power sign (1) for 1-2 seconds. (The blower will be running at the same speed as last used).
Note: The system saves user configurations, settings such as timer and blower (motor) speed will remain the same the next time it is turned on.
B. ADJUSTING BLOWER SPEED:
 Touch and hold down (+) for increase.
 Touch and hold down (-) for decrease.
C. TURNING OFF THE BLOWER:
 Touch and hold down power sign (1) for 1-2 seconds.
D. TO TURN THE LIGHT ON/OFF:
 Touch Light button (6) once to turn on the lights, and once again to turn off the lights.
E. ADJUSTING THE TIMER FUNCTION:
 While the blower (motor) is not running, touch and hold Decrease Value button (2) over 3 seconds (until it's flashing) to enter timer mode.
 Adjust to desired period of delay off timer by touching Increase Value or Decrease Value button (minimum 1 minute to maximum 15 minutes).
This setting will be saved immediately.
F. ACTIVATING THE TIMER FUNCTION:
While the blower (motor) is running, touch and hold "Power" button (1) for over 3 seconds to activate delay off timer.
Power-Off Delay Digital Timer
(10) will light up and
G. TO CLEAR CLEANING REMINDER:
 When blower (motor) starts to rotate, cumulative running time will be shown in
is up and reminds user to clean the baffle filters.
 After cleaning the filters and when the motor is not in use, touch and hold (+)
that turning off the system will not reset the

12. SPECIFICATION

Body Design
Power Rating
General Input Power
Motor Input Power
Ampere
Levels Of Speed Control
Maximum Airflow
Noise Level
Number Of Motors
Motor Type
Fan Type
Filtration Type
Illumination
Venting Size
Interference Protection
Note
(9) will begin to countdown. When it reaches zero, the blower (motor) will shut down.
Power-On Elapsed Digital Timer (8)
Non-Magnetic 1.0 mm Stainless Steel, Satin Finish
120V/60Hz (USA & Canada standard)
158W (150W + 4x2W)
150 W each
1.3 A
4 Levels
900CFM
Approximately 1.5 – 6.0 sones or 33 – 54 dB
Single Motor
Single Chamber Ultra Quiet
Squirrel Cage blower
Heavy Duty Stainless Steel Baffle Filter
4 LED lights, 2W Maximum/each
Top 6 inches Round
Radio Frequency Interference Protected
Specification subject to change without notice.
www.XtremeAirUsa.com
Power-On Elapsed Digital Timer (8)
Increase Value
button (7) over 3 seconds to reset the timer. Please note
.
Power-Off Delay Timer Indicator
. This timer icon flashes when 30 hours
PAGE
8

Advertisement

Table of Contents
loading