17. Being that the RPM signal is
critical you will need to
solder the connection.
Using wire strippers create
a
1"
window/gap
insulation of the wire.
Then
strip about
insulation of the RPM signal
wire of the BLUE wire from
the PAS wiring harness.
Wrap
the
around the factory RPM
signal wire and solder this
connection.
Then use electrical tape to
wrap this connection so that
it is water tight.
You can also cut the factory
crank signal wire and use
heat shrink tubing if you
would like.
US Shipping Address: 88-446 Harrison St, Sumas, WA 98295 US Mailing Address: PO Box 231, Sumas, WA 98295
Ford 7.3L 1999.5-2003 Positive Air Shutoff
in
1"
of
copper
wire
Plant Address: A10-33733 King Rd, Abbotsford, BC, Canada V2S 7M9
Phone: 604-853-6096 Fax: 604-853-8749 Internet: www.bd-power.com
Solder the connection and then wrap