Lennox LCH036 Installation Instructions Manual page 96

Table of Contents

Advertisement

LGH/LCH092H4M, 102H4M, 120H4M, 150H4M (2-Compressor) Staged Belt Drive
Factory Setting
Para­
meter
092
102
Note: Any changes to Smoke CFM setting must be adjusted before the other CFM settings. Use SETTINGS > RTU OPTIONS > EDIT
PARAMETERS
3000
3400
12
CFM
CFM
SETUP > TEST & BALANCE (can also use SETTINGS > RTU OPTIONS > BLOWER > SPEEDS)
3000
3400
CFM
CFM
2700
2200
CFM
CFM
1950
3050
CFM
CFM
3000
3400
CFM
CFM
*Once all four blower settings are entered, the target (highest of the heating and cooling settings) CFM will be displayed. Once the target CFM is
saved, all other blower CFM are set by the Unit Controller.
SETUP > TEST & BALANCE (can also use SETTINGS > RTU OPTIONS > DAMPER)
0%
0%
0%
0%
50%
50%
SETTINGS > RTU OPTIONS > EDIT PARAMETERS
29
101%
101%
101%
216
5%
5%
Factory Setting
Paramet­
er
094
Note: Any changes to Smoke CFM setting must be adjusted before the other CFM settings. Use SETTINGS > RTU OPTIONS > EDIT
PARAMETERS
12
3000 CFM
4000 CFM
SETUP > TEST & BALANCE (can also use SETTINGS > RTU OPTIONS > BLOWER > SPEEDS)
3000 CFM
4000 CFM
2700 CFM
3600 CFM
1950 CFM
2600 CFM
3000 CFM
4000 CFM
*Once all four blower settings are entered, the target (highest of the heating and cooling settings) CFM will be displayed. Once the target CFM is
saved, all other blower CFM are set by the Unit Controller.
SETUP > TEST & BALANCE (can also use SETTINGS > RTU OPTIONS > DAMPER)
0%
0%
50%
SETTINGS > RTU OPTIONS > EDIT PARAMETERS
29
101%
216
5%
SETTINGS > RTU OPTIONS > EDIT PARAMETER
85
40°F
86
40°F
Field
120
150
Setting
4000
5000
CFM Blower CFM during smoke detection.
CFM
CFM
4000
5000
CFM
CFM
CFM
3600
4500
CFM
CFM
CFM
2600
3250
CFM
CFM
CFM
4000
5000
CFM
CFM
CFM
0%
0%
% Damper min. position during LOW blower operation.
0%
0%
% Damper min. position during HIGH blower operation.
50%
50%
% Min. damper % for stage 1 power exhaust operation.
101%
%
Open
5%
5%
% Deadband % for stage 1 power exhaust operation.
LGH/LCH094U4M, 122U4M, 152U4M (2-Compressor) Staged Belt Drive
122
152
5000 CFM
5000 CFM
4500 CFM
3250 CFM
5000 CFM
0%
0%
0%
0%
50%
50%
101%
101%
5%
5%
40°F
40°F
40°F
40°F
TABLE 35
580682
Blower CFM during heating.
Blower CFM during high speed (2 compressor) cooling.
Blower CFM during low speed (1 compressor) cooling.
Blower CFM during ventilation.
Damper minimum position during G blower operation. (Setting parameter 29 to "101"
disables parameter 29 and passes control to parameter 9 or 132)
TABLE 36
580686
Field
Setting
CFM Blower CFM during smoke detection.
Blower CFM during heating.
CFM
Blower CFM during high speed (2 compressor) cooling.
CFM
Blower CFM during low speed (1 compressor) cooling.
CFM
Blower CFM during ventilation.
CFM
% Damper min. position during LOW blower operation.
% Damper min. position during HIGH blower operation.
% Min. damper % for stage 1 power exhaust operation.
Damper minimum position during G blower operation. (Setting paramet­
er 29 to "101" disables parameter 29 and passes control to parameter 9
%
Open
or 132)
% Deadband % for stage 1 power exhaust operation.
Compressor 1 low temp lockout. Settings lower than 40°F could void
°F
warranty.
Compressor 2 low temp lockout. Settings lower than 40°F could void
°F
warranty.
Page 46