Safety
1 - Keep unit area clear and free of combustible
materials, gasoline and other flammable vapors and
liquids.
2 - Do not obstruct air flow to unit. Unit must receive an
unobstructed flow of combustion and ventilating air.
WARNING
Danger of explosion and fire. Failure to
follow safety warnings exactly could result in
dangerous operation, serious injury, death or
property damage.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
FBR113270
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
Installation and service must be per-
formed by a qualified installer, service
agency or the gas supplier.
USER'S INFORMATION MANUAL
LGH092, 094, 120, 122, 150, 152
LGH156, 180, 210, 240, 300S/U
READ ALL INSTRUCTIONS IN THIS MANUAL
AND RETAIN FOR FUTURE REFERENCE
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings
exactly could result in serious
injury, death, or property damage.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Extinguish any open flames.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediatly
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's in-
structions.
• If you cannot reach your gas supplier, call the
fire department.
LGH036, 048, 060, 072, 074
(7-1/2, 8-1/2, 10 and 12-1/2 Tons)
(13, 15, 17-1/2, 20 and 25 Tons)
LGH242, 300H, 360
ROOFTOP UNITS
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer or
equivalent, service agency, or the gas supplier.
WARNING
Danger of electrical shock, explosion and
fire. Improper servicing could result in
dangerous operation, serious inujry, death
or property damage.
(3, 4, 5 and 6 Tons)
(20, 25 and 30 Tons)

Advertisement

Table of Contents
loading

Summary of Contents for Lennox LGH036

  • Page 1 USER’S INFORMATION MANUAL See unit nameplate for manufacturer and address. LGH036, 048, 060, 072, 074 ©2019 507246-02 (3, 4, 5 and 6 Tons) 6/2019 LGH092, 094, 120, 122, 150, 152 Supersedes 7/2018 (7-1/2, 8-1/2, 10 and 12-1/2 Tons) LGH156, 180, 210, 240, 300S/U...
  • Page 2 LGH036, 048, 060S, H & 072, 074H Parts Arrangement REHEAT COIL EVAPORATOR BLOWER (OPTIONAL) COIL FILTERS (4) MOTOR 036, 048:16 X 20 X 2” CONDENSER (BELT DRIVE SHOWN) 060, 072, 074: 20 X 20 X 2” ECONOMIZER (OPTIONAL) BLOWER COIL...
  • Page 3 LGH156, 180, 210, 240, 300S/U Parts Arrangement EVAPORATOR FILTERS CONDENSER FANS ECONOMIZER COIL (SIX - 24 X 24 X 2”) (3 FANS ON 156 UNITS; DAMPERS (OPTIONAL) 6 FANS ON 180U, 210, 240, & 300S/U UNITS BLOWERS BLOWER MOTOR UNIT CONTROLLER CONDENSER COILS (RIGHT COIL...
  • Page 4: Unit Operation

    The unit is equipped with an automatic spark ignition sys- CAUTION tem. There is no pilot. In case of a safety shutdown, move thermostat switch to OFF and return the thermostat switch Label all wires prior to disconnection when servicing to HEAT.
  • Page 5: Burner Flame

    7 - Turn gas valve switch to ON. See Figure 1, Figure WHITE RODGERS 36J54 GAS VALVE 2, or Figure 3. On Honeywell VR8305Q gas valves, Two-Stage turn knob on gas valve counterclockwise to ON. HIGH FIRE MANIFOLD Do not force. See Figure 4. PRESSURE TAP ADJUSTMENT 8 - Close or replace the heat section access panel.
  • Page 6: Heat Exchanger Assembly

    Flue Passage and Vent Inspection HEAT EXCHANGER ASSEMBLY 156-360 UNITS Annually, before heating season, inspect the combustion HEAT air louvers, vent cap, heat exchanger, burners and com- EXCHANGER bustion air inducer for corrosion, deterioration or deposits TUBE of debris. Remove any obstructions or blockage. See Fig- COMBUSTION ure 5, Figure 6, or Figure 7.
  • Page 7: Flame Sensor

    to the unit and use the inspection port in the access TABLE 1 panel to check the flame. UNIT FILTERS BURNER BOX ASSEMBLY Unit Filter Size - inches (mm) 036-074 UNITS - ONE- & TWO-STAGE 036, 048 16 X 20 X 2 (406 X 508 X 51) 060, 072, 074 20 X 20 X 2 (508 X 508 X 51) 092, 094, 102, 120,...
  • Page 8: Repair Parts Listing

    Combustion Air Inducer On 156-360 units, replace mullion. 9 - Use a small brush to clean the combustion air inlet A combustion air inducer proving switch checks combus- louvers on the heat access panel. tion air inducer operation before allowing power to the gas controller.