Water Connection - Bosch TRONIC 1000 T Installation And Operating Instructions Manual

Dhw tank
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 150
Installation (only for approved contractors)
Vertical installation
Fig. 10
Vertical installation
Appliance
Standard diameter type
Slim diameter type
Table 6
Horizontal installation
Fig. 11
Horizontal installation (TR1000...H)
Appliance
...80...
...100...
Table 7
When mounting horizontally:
▶ ensure that the hydraulic connections are perpendicular
and located at the lower part of the device.
160
A
240
340
A
350
495
5.4

Water connection

NOTICE
Risk of damage to property!
Risk of corrosion damage to the appliance's connections.
▶ Use galvanic isolators on the water connections. This will
prevent electric (galvanic) currents between the metals of
the hydraulic connections and, consequently, their
possible corrosion.
NOTICE
Risk of damage to property!
▶ Install a filter in the water inlet in locations where the water
presents suspended matter.
▶ When using PEX pipes, install a thermostatic control in the
outlet pipe of the appliance. This must be adjusted to match
the performance of the material used.
▶ The pipes used must be designed for 10 bar (1 MPa) and
100 °C.
Recommendation:
▶ Flush the system before the installation since the presence
of sand particles can cause a reduction of the flow and
consequently the limit, and total obstruction.
▶ Make sure the cold and hot water tubes are duly identified,
in order to avoid confusion.
Fig. 12
[1] Cold water inlet (right)
[2] Hot water outlet (left)
Tronic 1000 T | Tronic 2000 T – 6721831855 (2021/03)