Water Connection - Bosch Tronic 4000 T Series Installation And Operating Instructions Manual

Dhw cylinder
Hide thumbs Also See for Tronic 4000 T Series:
Table of Contents

Advertisement

Device
ES050...
ES080...
ES100...
ES120...
ES150...
Table 7
5.4

Water connection

NOTICE: Corrosion damage to the DHW
cylinder's connections!
▶ Provide the water connections with
insulating dielectric unions. This prevents
current (DC current) from flowing between
the metal hydraulic connections and the
resulting corrosion.
NOTICE: Material damage!
▶ Use a filter at the water inlet if the water has
suspended matter.
Recommendation:
▶ Flush the system beforehand as the water
flow could be reduced by contaminants and,
in case of severe contamination, be stopped
completely.
▶ Mark the cold water lines and the DHW lines accordingly to
avoid confusion (Fig. 10).
2
Fig. 10
[1] Cold water inlet (right)
[2] Hot water outlet (left)
Tronic 4000 T | Tronic 6000 T
▶ Use suitable accessories for the hydraulic connection of
D
the DHW cylinder.
180
407
552
702
927
1
Fig. 11
[1] Isolation fitting
[2] Hot water outlet
[3] Pressure relief valve
[4] Siphon connection
[5] Gate valve
[6] Pressure reducing valve
[7] Check valve
[8] Connection to the water line
Risk of frost:
▶ Switch off the DHW cylinder.
▶ Drain the DHW cylinder ( sec. 6.3).
Pressure relief valve
1
6720812247-02.1V
5
2
1
3
4
Water connection
We recommend the installation of a non-return
valve upstream of the cylinder to prevent faults
resulting from sudden pressure fluctuations in
the water supply (Fig. 11, [7]).
DANGER:
▶ Fit a pressure relief to the cold water
connection on the DHW cylinder (Fig. 11).
Installation | 9
6
7
8
6720818520-06.1V
6 720 818 731 (2016/07)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents