Astria Fireplaces Scorpio Series Installation And Operation Instructions Manual

Direct-vent gas fireplaces

Advertisement

P/N 900683-00 REV. C 05/2017
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900683-04.
P900683-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Installation and Operation Instructions
Scorpio™ Series Direct-Vent Gas Fireplaces
Models
C
US
Report No. F13-094
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
Scorpio35DEN-B
Scorpio40DEN-B
Scorpio35DEP-B
Scorpio40DEP-B
ScorpioCD35DEN-B
ScorpioCD40DEN-B
ScorpioCD35DEP-B
ScorpioCD40DEP-B
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
Scorpio45DEN-B
Scorpio45DEP-B
ScorpioCD45DEN-B
ScorpioCD45DEP-B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Scorpio Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Astria Fireplaces Scorpio Series

  • Page 1 Installation and Operation Instructions Scorpio™ Series Direct-Vent Gas Fireplaces P/N 900683-00 REV. C 05/2017 Models Scorpio35DEN-B Scorpio45DEN-B Scorpio40DEN-B Ce manuel est disponible en francais, simplement Scorpio35DEP-B Scorpio45DEP-B Scorpio40DEP-B en faire la demande. Numéro de la pièce 900683-04. ScorpioCD45DEN-B ScorpioCD35DEN-B ScorpioCD40DEN-B Report No.
  • Page 2: General Information

    Innovative Hearth Products General Information Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 SAFETY AND YOUR FIREPLACE See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is pro- vided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3 Innovative Hearth Products General Information Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 La sécurité et Safety and Your Seguridad y su votre foyer Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fireplace get chimenea IHP se ponen foyer IHP deviennent EXTRÊMEMENT CHAUDES !
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Traditional - Charred Oak Logs Contemporary THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
  • Page 5: Important Safety Information

    Innovative Hearth Products General Information Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 IMPORTANT SAFETY INFORMATION Important Safety Informa- L’information de sûreté Información importante de tion importante seguridad 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked si le panneau frontal en verre n’est pas en frente de vidrio quitado, agrietado o roto.
  • Page 6: Fireplace Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
  • Page 7 Innovative Hearth Products General Information Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 APPLIANCE OPERATION NOTICES These fireplaces are vented gas appliances. Do not burn wood or other material in these appliances. These appliances are designed to operate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous.
  • Page 8: Packaging List

    Innovative Hearth Products General Information Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 INSTALLATION PACKAGING All models include The assembled vented gas fireplace heater is packaged with: • Literature Kit (envelope in bottom compartment containing Installation and Operation Instructions (this manual), Hot Glass Safety Flyer, and Safety-In-Operation Warning Labels) •...
  • Page 9: Gas Pressure

    Innovative Hearth Products General Information Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 BTU Input Table 1 - Input Rate (BTU/HR), Gas Valves Natural Gas Propane Gas Models High Rate Low Rate High Rate Low Rate 35” Models 20,000 14,000 19,000 13,000 40”...
  • Page 10: Requirements For The Commonwealth Of Massachusetts

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
  • Page 11: Cold Climate Insulation

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 COLD CLIMATE INSULATION For cold climate installations, seal all cracks around your fireplace with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which fireplace rests, if floor is above ground level.
  • Page 12: Manufactured Home Requirements

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
  • Page 13: Vent Termination Clearances

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 VENT TERMINATION CLEARANCES These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 14 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Table 7 - Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors Inside Corner Outside Corner Recessed Location See Table 6 Fixed Balcony with No Side Wall Balcony with Perpendicular Side Wall Openable Fixed Closed...
  • Page 15: Minimum Clearances To Combustibles

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fireplace is approved with zero clearance to combustible materials on all sides (Table 8), with the following exception: The unit may not be recessed (allowance made for mantel legs / side trim in Figure 5). When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit (Figure 5).
  • Page 16: Wall Finishes / Surrounds / Mantels

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Figure 5 - Combustible Side Clearances Figure 6 - Mantel Height At 6” minimum side wall clearance, Mantel depth Top View of a combustible wall 20 (508) Fireplace can project to any length.
  • Page 17: Installation Sequence

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 INSTALLATION SEQUENCE The typical sequence of installation is outlined below; however, each installation is unique and may result in variations to the steps described. See the pages referenced in the following steps for detailed instructions. Framing 1.
  • Page 18 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Table 10 - Fireplace Framing Specifications Model Framing NOTE: Dimension “D” is the construction to be 10-1/2 required framing depth when 35-3/8 36-1/4 38-3/4 23-3/8 2 x 4, or larger. 35”...
  • Page 19: Prepare The Fireplace Top Spacers

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Prepare the Fireplace Top Spacers 1. The two (2) 4” standoff spacers on top of the fireplace cabinet are shipped flat. Remove the screw adjacent to the detached end (Figure 7). 2.
  • Page 20: Determine Vent Setup In The Combination Venting Unit

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Determining Vent Setup in the Combination Venting Unit Combination venting units are shipped with rear venting setup nearly ready for install. If this is the type of vent you require, remove all insulation packing and flue plug block off from rear venting and proceed with fireplace installation.
  • Page 21: Rough In The Electrical Supply, If Needed

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Rough in the Electrical Supply, if Needed As necessary, rough in the fireplace electrical supply per NEC and local codes. Place the Fireplace in the Framing and Secure NOTE: Nailing flanges, combustible members, and screw heads in areas directly adjacent to the nailing flanges are EXEMPT from the 1/2”...
  • Page 22: Install The Vent Restrictor (If Necessary)

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Install the Vent Restrictor (if necessary) 1. Use the vent run descriptions in Figure 11 to determine if a vent restrictor is necessary. U-Shaped Vent 2. If necessary, assemble the vent restrictor and wing as detailed in Figures 11 and 14. Restrictor 3.
  • Page 23 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Connecting the Vent Pipe Secure Vent SV4.5 direct-vent system components are unitized concentric pipe components featuring positive twist ® lock connections (Figures 15–16, Page 23). All of the fireplaces covered in this document are fitted with collars having locking inclined channels.
  • Page 24 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Vent section length table Table 14 will assist calculating how many vent sections are needed for the planned vent configuration. When a vent section is engaged with another section, its effective length will be 1-1/2” shorter. Table 14 - Vent Section Length Nominal Section Nominal Section Length...
  • Page 25: Install The Vent System

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Clearance to combustibles Maintain the minimum clearance to combustibles (e.g., framing, attic, ceiling insulation, etc.). For all vertical runs: • 1” (26 mm) from all sides NOTE: Attic insulation shield (H3907, see Page 47) must be installed when blown or loose-fill insulation is used, and is required for all attic installations.
  • Page 26 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Vertical (Offset) Installation 1. Analyze the vent route and determine the number of vent sections and elbows required—See Effective Vent Length on Pages 23-24 for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists.
  • Page 27 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 7. Change vent direction of horizontal/inclined run—Install the SV4.5E45 and SV4.5E90 elbows in the same manner as the straight vent sections. See Vent elbows on Page 23 for more information. 8.
  • Page 28 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Vertical Vent Figures/Tables NOTE: Secure Vent rigid vent pipe is shown in the figures; Secure Flex flexible vent pipe may also be used. ® ® NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane of approximately 1/4”...
  • Page 29 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Table 17 - Top Vent—Two 90° Elbows Table 18 - Rear Vent—Three Elbows Table 19 - Top Vent—Three Elbows When using Secure Flex , use ® ceiling firestop/ Ceiling firestop/ spacer SF4.5VF.
  • Page 30 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 31 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 8. Change vent direction—At transition from or to a horizontal/inclined run, install SV4.5E45 or SV4.5E90 elbows in the same manner as the straight vent sections. The elbows feature a twist section to allow them to be routed about the center axis of their initial collar section to align with the required direction of the next vent run element.
  • Page 32 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Figure 25 - Installing the Horizontal Termination To help minimize water infiltration Firestop/Spacer (SV4.5HF) shown Typical it is recommended that the Fire- Termination on the exterior side of the wall. It Shown stop/ Spacer (SV4.5HF) be installed may also be installed on the...
  • Page 33 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Table 20 - Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness Termination Kit Only 6 to 9-1/4” (152 to 235 mm) Termination Kit and 6”...
  • Page 34 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Table 23 - Top Vent—One 90° Elbow, Elbow Connection NOT at Fireplace H Maximum V Minimum feet meters feet meters 1.524 0.305 When using Secure Flex, 3.048 0.610 use Firestop/Spacer SF4.5VF.
  • Page 35 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Table 26 - Rear Vent—Three 90° Elbows H + H Maximum H Maximum V Minimum feet meters feet meters feet meters Wall firestop/spacer Wall Firestop/Spacer SV4.5HF ** 1.524 0.610 0.305 SV4.5HF** 3.048...
  • Page 36 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Vertical or Horizontal Venting Using Secure Flex Kits and Components ® When Secure Flex kits are used in a rear flue, horizontal termination installation, at least 1 ft of vertical rise is required. ®...
  • Page 37: Complete The Field Wiring

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 f. Install three (3) screws 120° apart through the flexible vent and into the adaptor collar just below the gear clamp to provide additional security to the connection. 3. Route the flexible vent. NOTE: Ensure that the flexible vent is properly routed to provide the required clearance.
  • Page 38 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Figure 29 - Wiring Diagram—Electronic Gas Valve Ecoflow Electronic Pilot Gas Valve Burner 2 Main Burner Thermocouple Ground - Connector to Chassis Ground or Valve Body Thermocouple - To “S” Valve Terminal on Main Module Step...
  • Page 39: Connect The Gas Line

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Figure 30 - Wiring Diagram—Junction Box 4. Connect the black power supply wire to the lower outlet’s black and red pigtail lead (Figures 29 and 30). Connect the white power supply wire to the Green Ground - Green White...
  • Page 40: Verify Proper Fireplace Operation

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 NOTE: A sediment trap is recommended in the gas piping within the home to prevent moisture and debris in the line from damaging the valve. NOTE: Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resistant compounds are used in propane applications).
  • Page 41: Initialize The Remote Control System For The First Time

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Figure 32 - Electronic Pilot Igniter Pilot Hood Flame Rod Initialize the Remote Control System for the First Time 1. Install the four (4) AAA batteries. NOTE: Check the polarity (+/-) of the batteries and insert them into the battery bay as indicated on the battery cover.
  • Page 42 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Remote Control Display THERMOSTAT OFF LCD Displays: • MODE Zone: THERMO and OFF is displayed • ROOM TEMP Zone: Measured temperature is displayed • SET TEMP Zone: SET TEMP is displayed •...
  • Page 43: Optional: Install The Firebox Liners

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Optional: Install the Firebox Liners 1. See Page 53 for instructions on Traditional Only: Installing the Firebox Liners. Traditional Fireplaces: Install the Logs, Volcanic Stone, and Glowing Embers 1. See Pages 54–61 for instructions on Installing the logs, volcanic stone, and glowing embers. Contemporary Fireplaces: Install Glass Media 1.
  • Page 44 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Figure 34 - Air Shutter Adjustment Rod Table 28 - Air Shutter Adjustment Guidelines Adjustment Set-Screw Amount of Primary Flame Color Air Shutter Adjustment Adjustment Rod Up Burner If air shutter is Flame will (Fully-Closed Air shutter gap should be increased...
  • Page 45: Install The Hood

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Install the Hood NOTE: All models must have a hood installed prior to operation. 1. Install the hood by sliding it into the slots on the lower edge of the cabinet top. NOTE: To install the non-combustible finish material flush with the top of the hood, the hood must be installed before installing the finish material.
  • Page 46 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 INSTALLER INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. ATTACHING SAFETY IN OPERATION APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD...
  • Page 47: Installation Accessories

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 INSTALLATION ACCESSORIES Listed Secure Vent Components ® Cat. No. Model Description Cat. No. Model Description Horizontal Square Termination H1968 SV4.5HT-2 with Firestop/Spacer (H2246), H6183 SV4.5HF5 Firestop Spacer, 5”, rigid and Adaptor (74L61) H6184 SF4.5HF5...
  • Page 48 Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 INSTALLATION ACCESSORIES (continued) Listed Secure Flex Components ® Cat. No. Model Description Cat. No. Model Description Vertical Termination for flex (flat 18 ft (5.49 m)* compressed flex 60L10 SF-18 to 6/12) with flex adaptor, section (see 750053M) 56L74...
  • Page 49: Gas Conversion Kits

    Innovative Hearth Products Installation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 GAS CONVERSION KITS WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion, or the production of carbon monoxide may result;...
  • Page 50: Operation

    Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.
  • Page 51 Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARN- APPOSITION DES MISES EN GARDE RELATIVES À COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD INGS LA SÉCURITÉ D’UTILISATION EN OPERACIÓN Votre foyer a été...
  • Page 52 Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Burn-in Period The first few times this fireplace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few days.
  • Page 53 Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Installing the Backup Batteries With a battery backup, electronic fireplaces can automatically switch to battery power. In the event of a power outage, this allows ON/OFF operation (without blower functionality). Install new batteries before every burn season. 1.
  • Page 54 Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Install the Logs, Volcanic Stone, and Glowing Embers WARNING • Turn OFF all gas and electricity to the appliance before installing the volcanic stone, embers, and logs. • Do NOT install the logs until the appliance has been completely installed, the gas line connected and tested for leaks, and the initial burner operation has been confirmed.
  • Page 55 Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Installing the Scorpio™ 35/40/45 Series Driftwood Logs The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between flame peaks, so they do not impinge the flames.
  • Page 56 Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Installing the Scorpio™ 35/40/45 Series Driftwood Logs (continued) 6. Position the right bottom log (4) on the corner of the grate (Figure 47) and as shown in Figure 48. 7.
  • Page 57 Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Installing the Scorpio™ 35 Series Charred Oak Logs The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between flame peaks, so they do not impinge the flames.
  • Page 58 Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Installing the Scorpio™ 35 Series Charred Oak Logs (continued) 6. Position the Top Front Left Log (4), shown in Figure 55 on the landing area outlined in Figure 54. Figure 55 - Place log #4...
  • Page 59 Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Installing the Scorpio™ 40/45 Series Charred Oak Logs The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between flame peaks, so they do not impinge the flames.
  • Page 60 Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Installing the Scorpio™ 40/45 Series Charred Oak Logs (continued) 5. Align the notch on the bottom of the front right log (3) over the front right locating tab. See Figures 56 and 60. 6.
  • Page 61 Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Installing and removing the glass door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage—Do not scratch or handle roughly while reinstalling the glass door frame.
  • Page 62 Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Installing the glass door 1. Visually inspect the gasket on the backside of the glass door. NOTE: The gasket surface must be clean, free of irregularities, and seated firmly. Ensure it is properly located. Make sure the bead is not rolled into the channel at the top of the door, but remains flat against the top of the glass.
  • Page 63: Maintenance

    Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 MAINTENANCE Refer to the Maintenance Schedule on Page 65 for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper fireplace operation after servicing. WARNING Turn OFF gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
  • Page 64 Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Inspecting the glass gasket Visually inspect the gasket on the backside of the glass door. The gasket surface must be clean, free of irregularities, and seated firmly. Cleaning the control compartment Keep the control compartment clean by vacuuming or brushing it out at least twice a year.
  • Page 65 Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By Procedure Inspecting/Cleaning Burner, Logs, and Qualified Service Technician Inspect valve and ensure it is properly Controls...
  • Page 66: Accessory Components

    Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 ACCESSORY COMPONENTS Termination Shroud (fits H1968) Clear (standard) Blue Black Reflective Porcelain Firebox Liner Kits - Traditional Models Deluxe Termination Guard (fits 94L10 and H1968) Cat. No. Model Description Used on Amber Green...
  • Page 67 Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 ACCESSORY COMPONENTS (continued) LOG SETS - REQUIRED OPTION Andiron Kit - Traditional Models Cat. No. Model Description Log Sets - Traditional Models F2227 AKT-DV4 Andiron Kit Cat. No. Model Description F2876 CHAROAK35SPO...
  • Page 68: Lighting Instructions

    Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 LIGHTING INSTRUCTIONS, ELECTRONIC ECOFLOW - ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 69 Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 LIGHTING INSTRUCTIONS, ELECTRONIC ECOFLOW - FRENCH POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 70: Troubleshooting

    Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 TROUBLESHOOTING ELECTRONIC SYSTEMS Before troubleshooting, ensure that the fireplace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the fireplace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 71: Replacement Parts

    Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 REPLACEMENT PARTS 35” Models 40” Models 45” Models Description Catalog Number Catalog Number Catalog Number Black Touch-Up Paint, Powder Coat, Exterior F1882 F1882 F1882 Black touch-up paint, Satin Black, Interior F3373 F3373 F3373...
  • Page 72 Innovative Hearth Products Operation Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 REPLACEMENT PARTS (continued) 35” Models 40” Models 45” Models Catalog Catalog Catalog Number Number Number ECOFLOW PARTS Pilot Assembly, Ecoflow, Natural Gas J7935 J7935 J7935 Pilot Assembly, Ecoflow, Liquid Propane J7962 J7962 J7962...
  • Page 73: Warranty

    Innovative Hearth Products Astria Brand Gas Fireplace ® Limited Lifetime Warranty THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria brand gas fi replace ("Product") to be free from defects in materials and workmanship ® at the time of manufacture. The product body, fi rebox and barrier carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 74 Innovative Hearth Products Installation and Operation Instructions Scorpio™ Series Direct-Vent Gas Fireplaces 900683-00, 05/2017 Astria.us.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name IHP reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Table of Contents

Save PDF