Astria Fireplaces LibraST40DMN Installation & Operation Instructions

Multi-view series direct-vent gas fireplaces
Table of Contents

Advertisement

Quick Links

P/N 900299-01 Rev. C 05/2016
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900299-03.
P900299-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Installation and Operation Instructions
Libra
Models
PFS
LibraST40DMN
®
LibraST40DMP
C
US
LibraST40DEN
Report No. 14-171
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
Multi-View Series Direct-Vent Gas Fireplaces
TM
LibraPF40DMN
LibraPF40DMP
LibraPF40DEN
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
LibraCL40DMN
LibraCR40DMN
LibraCL40DMP
LibraCR40DMP
LibraCL40DEN
LibraCR40DEN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LibraST40DMN and is the answer not in the manual?

Questions and answers

Summary of Contents for Astria Fireplaces LibraST40DMN

  • Page 1 Installation and Operation Instructions Libra Multi-View Series Direct-Vent Gas Fireplaces P/N 900299-01 Rev. C 05/2016 Models Ce manuel est disponible en francais, simplement LibraST40DMN LibraPF40DMN LibraCL40DMN LibraCR40DMN en faire la demande. Numéro de la pièce 900299-03. ® LibraST40DMP LibraCL40DMP LibraCR40DMP...
  • Page 2: Safety And Your Fireplace

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ SAFETY AND YOUR FIREPLACE See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.
  • Page 3 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ La sécurité et Safety and Your Seguridad y su votre foyer Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fireplace get chimenea IHP se ponen foyer IHP deviennent...
  • Page 4: Table Of Contents

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ PACKAGING Use only the correct size venting (4-1/2" inner TABLE OF CONTENTS and 7-1/2" outer). Safety and Your Fireplace ......Page 2 The assembled vented gas fireplace heater is Packaging ...........Page 4 packaged with: These approved vent system components are...
  • Page 5 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ NOTE: Installation and repair should be done Misc. Codes / Standards - DO NOT ATTEMPT TO ALTER OR MODIFY The Installation must conform to local codes or, by a qualified service person.
  • Page 6: Commonwealth Of Massachusetts

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ Gas Pressure - All Models Deration - At higher elevations, the amount of BTU fuel value delivered must be reduced Tables 2 and 3 show the appliances' inlet and by either: manifold gas pressure requirements: •...
  • Page 7: Cold Climate Insulation

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ COLD CLIMATE INSULATION For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level.
  • Page 8: Vent Termination Clearances

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ Be aware that this is a heat producing ap- Vertical Vent Termination Clearances pliance. Objects placed above the unit are Termination Heights For Vents exposed to elevated temperatures. Above Flat Or Sloped Roofs TERMINATION HEIGHTS FOR VENTS ABOVE FLAT OR SLOPED ROOFS...
  • Page 9 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS Inside Corner Outside Corner Recessed Location See Figure 5 Fixed Balcony with No Side Wall Balcony with Perpendicular Side Wall Openable Fixed Closed Closed...
  • Page 10: Appliance And Vent Clearances

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ Hearth Extension MINIMUM CLEARANCES TO COMBUSTIBLES - A hearth extension is not required with this appliance. If a hearth exten- Appliance And Vent Clearances sion is used, do not block the lower control compartment door.
  • Page 11: Detailed Installation Steps

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ MINIMUM CLEARANCES WARNING Inches (millimeters) Back and Sides 1/2" (13) Failure to position the parts in 0 (0) from Spacers Or Dimples ** accordance with these diagrams Top Spacers 0 (0) or failure to use only parts...
  • Page 12: Typical Installation Sequence

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ Step 2. (Page 16) Route gas supply line to Step 10. (Page 36) Install glass door assembly. appliance location. Pressure Relief Step 11. (Page 36) Adjust burner to ensure Plates Step 3.
  • Page 13: Fireplace And Framing Specifications

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ FIREPLACE FRAMING SPECIFICATIONS LibraST LibraST LibraPF 11-3/8 inches (millimeters) inches (millimeters) LibraPF 11-3/8 (289) (See-Through) (See Through) Minimum Framing (Peninsula) Minimum Framing (Peninsula) 10-1/2 10-1/2 Stud Size is 2x4 Stud Size is 2x4 (267)
  • Page 14 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ FIREPLACE SPECIFICATIONS LibraST (See-Through) ST (See-Through) 50-3/8 (1280) 48-1/4 (1200) FINISHED WALL BRACKET 48 (1219) (Front and back edge of unit top) TOP VIEW NOTE: Unit has a factory-installed FRAMING vent seal cap and vent cover plate SPACERS...
  • Page 15 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ FIREPLACE SPECIFICATIONS CONTINUED CL (Corner-Left) LibraCL (Corner-Left) FINISHED WALL BRACKET (Front and back edge of unit top) TOP VIEW (254) NOTE: Unit has a factory-installed vent seal cap and vent cover plate (see 11-3/8 Figures 22-23 on Page 17) in each flue...
  • Page 16: Step 2. Routing Gas Line

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ Step 2. ROUTING GAS LINE IMPORTANT: If propane is used, be aware that Installing a gas supply line from the fuel supply to the appliance involves numerous considerations if tank size is too small (i.e.
  • Page 17: Step 4. Install The Venting System

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ Step 4. INSTALL THE VENT SYSTEM Securing Screws Top Vent Vent Seal Cap General Information (OUTSIDE of Appli ance) These instructions should be used as a guideline and do not supersede Insulation local codes in any way.
  • Page 18: Vertical Termination Systems

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ VERTICAL TERMINATION SYSTEMS (ROOF) i t c i t c See Figure 25 and Figures 35 through 39 i t c on Pages 21 and 22 and their associated i t c Vertical Vent Tables which illustrate the various o i t...
  • Page 19: Sv4.5Cgv-1

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ Vertical (Offset) Installation B. Attach vent components to appliance - Se- C. Attach vent components to each other - Other SV4.5 Direct-Vent system compo- vent sections may be added to the previously cure Vent ®...
  • Page 20 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ F. Change vent direction to horizontal/inclined H. Frame roof opening - Identify location for run - At transition from or to a horizontal/in- vent at the roof. Cut and/or frame opening per clined run, install the SV4.5E45 and SV4.5E90 Roof Framing Chart and Figure 31.
  • Page 21: Vertical Vent Tables And Figures

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ VERTICAL VENT FIGURES/TABLES Table A NOTE: Secure Vent (rigid vent pipe) is shown ® in the figures; Secure Flex (flexible vent pipe) V Minimum ® H Maximum may also be used.
  • Page 22: Sv4.5Vf 1 6

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ VERTICAL VENT FIGURES / TABLES (CONTINUED) Table C Maximum H Maximum V Minimum feet (meter) feet (meter) feet (meter) Ceiling Firestop / (1.524) (0.610) (0.305) Spacer (SV4.5VF) (3.048) (1.219)
  • Page 23: Horizontal Termination System

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ HORIZONTAL (OUTSIDE WALL) Support Horizontal / Inclined Run TERMINATION SYSTEM Building Brackets Support Figures 40, and Figures 43 to 48 on Pages Framing SV4.5HT-2 Termination 25 to 27 and their associated Horizontal Vent SV4.5E90 Shown...
  • Page 24 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ J. Assemble vent run to exterior wall - If not To help minimize water infiltration it is previously measured, locate the center of the recommended that the Firestop/Spacer vent at the exterior wall.
  • Page 25: Horizontal Vent Tables And Figures

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ HORIZONTAL VENT FIGURES/TABLES Table F NOTE: Secure Vent components (rigid vent pipe and terminal) are ® V Minimum H Maximum shown in the figures; Secure Flex components (flexible vent pipe and ®...
  • Page 26 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ HORIZONTAL VENT FIGURES/TABLES (continued) Table G V Minimum Maximum H Maximum feet (meter) feet (meter) feet (meter) (1.524) (0.610) (0.305) (3.048) (1.219) (0.610) (4.572) (1.829) (0.914) Wall Firestop/ Spacer (SV4.5HF)
  • Page 27 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ HORIZONTAL VENT FIGURES/TABLES (continued) When using Secure Flex , use ® Wall Firestop / Spacer Example: If 20 feet total (H+H Firestop / Spacer SF4.5VF horizontal vent run is needed, then 4 (SV4.5HF) When using Secure Flex, use...
  • Page 28: Venting Using Flexible Vent Pipe

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ VERTICAL OR HORIZONTAL VENTING USING SECURE FLEX ® KITS AND COMPONENTS FLEX VENT NOTE: OUTER PIPE IS PULLED AWAY TO Secure Flex venting kits and components may ®...
  • Page 29: Step 5. Field Wiring

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ Step 5. FIELD WIRING Refer to Section A for millivolt appliances and NOTE: The supplied 15 feet of brown Section B for electronic appliances. The gas 2-conductor wire has one end of each conductor valve is set in place and pre-wired at the factory connected to the gas valve circuit and the other...
  • Page 30: Step 6. Optional Blower Kit Wiring

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ Step 6. WIRING - OPTIONAL FORCED AIR BLOWER KIT Plug blower Green into this White FBK-100, FBK-200 and FBK-250 Kits receptacle e t i (See Figure 54 on Page 29 for wiring) - 120 VAC - Black Black Junction Box...
  • Page 31: Step 7. Connecting Gas Line

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ Step 7. CONNECTING GAS LINE Step 8. VERIFYING APPLIANCE OPERA- Secure all joints tightly using appropriate tools and sealing compounds (ensure propane TION Make gas line connections. All codes require a resistant compounds are used in propane shut-off valve mounted in the supply line.
  • Page 32 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ Electronic Appliance Checkout Millivolt Appliance Checkout MILLIVOLT Hood Igniter Rod The pilot flame should be steady, not lifting To light the burner, turn ‘ON’ the unit mounted Thermocouple or floating.
  • Page 33: Step 9. Installing Logs

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ Step 9. INSTALL VERMICULITE, GLOWING EMBERS AND LOGS NOTE: It is important to ensure proper log placement per the manual when installing these units. Verify pilot flame is not obstructed. See Verifying Appliance Operation on Pages 31 and 32.
  • Page 34 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ LIBRAPF, LIBRAST, LIBRACL AND LIBRACR LOG PLACEMENT Log Number Description Log, Corner Log, Rear/Left Log, Front/Left Log, Rear/Right Log, Front/Center Log, Center/Top Catalog Number for the entire log set: 55M04 Log (3) Lays Over Logs 1 And 2 STEP 3...
  • Page 35 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ LIBRAPF, LIBRAST, LIBRACL AND LIBRACR LOG PLACEMENT (CONTINUED) Log Number Description Log, Corner Log, Rear/Left Log, Front/Left Log, Rear/Right Log, Front/Center Log, Center/Top Catalog Number for the entire log set: 55M04 Position The Round End Of Log (6) Position Small End Of Log (6) Against The Notch Of Log (4) Here.
  • Page 36: Step 10. Remove/Install Glass Door

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ Step 10. REMOVING AND INSTALLING Only doors certified with the appliance Step 11. BURNER ADJUSTMENTS THE GLASS DOOR shall be used. Flame Appearance and sooting Seules des portes certifiées pour Proper flame appearance is a flame which is cet appareil doivent être utilisées.
  • Page 37 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ NOTE: • If the barrier becomes dam- NOTICE: All Libra model fireplaces aged, the barrier shall be re- placed with the manufacturer’s include barriers to reduce the risk of barrier for this appliance.
  • Page 38: Step 12. Hood Installation

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ Air Shutter Adjusting Combustible Wall This Area Must Remain Orifice Framing 3" (77 mm) Clear of Combustible Materials Combustible Finished Wall Materials 1" Min. (26 mm) Increase Shutter Header Opening In This...
  • Page 39: Step 13. Attaching Safety In Operation Warnings

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ STEP 13. ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance.
  • Page 40: Installation Accessories

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ INSTALLATION ACCESSORIES Listed Secure Vent Components ® Cat. No. Model Description H1968 SV4.5HT-2 Horizontal Square Termina- tion With Firestop / spacer (H2246) & Adaptor (74L61) H2152 SV4.5CGV-1 Vertical Termination Cap,...
  • Page 41 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ INSTALLATION ACCESSORIES CONTINUED Listed Secure Vent Components Listed Secure Flex Components ® ® Cat. # Model Description Cat. # Model Description These termination kits include firestop/spacer, gear clamps and flex adaptor. 17M52 SV4.5HGS-1 Termination Guard, Square...
  • Page 42: Gas Conversion Kits

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ GAS CONVERSION KITS Natural to Propane Conversion Kit Models Unit type Catalog No. WARNING ST and PF Millivolt F2314 This conversion kit shall be installed by a qualified service agency in ST and PF Electronic F2316...
  • Page 43 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ d. Locate the two (2) latches at the top of the Inlet Pressure Test Port control compartment. To disengage the two latches from the bottom vee-flange of the glass enclosure panel, reach for the handles located Pressure Regulator...
  • Page 44: Care And Operation

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ Ensure that the arm of the venturi of the burner Step 9. Reassemble the remaining components is hooked onto the air shutter adjustment lever by reversing the procedures outlined in the (refer to Figure 67 on Page 41).The primary air preceding steps.
  • Page 45: Gas Controls Access

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ A white film may develop on the glass front AVERTISSEMENT WARNING during the first few fires as part of the curing process. The glass should be kept clean during L’appareil est chaud lorsqu’il fonc- Hot while in operation.
  • Page 46: Variable Flame Adjustment

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ Variable Flame Height Adjustment Variable Flame Height Adjustment Inlet Pressure Port ( Millivolt Appliances only) Manifold Pressure Port 1. All Millivolt appliances are equipped with a variable gas control valve.
  • Page 47: Attaching Safety In Operation Warnings

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD À LA SÉCURITÉ D’UTILISATION EN OPERACIÓN Your fireplace has been furnished with safety instruc- tion labels that are to be affixed to the operation and...
  • Page 48: Maintenance

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ MAINTENANCE The viewing glass should be cleaned periodi- Replacing Logs cally to remove any build-up caused from the following: If the logs become damaged by accident or (See Maintenance Schedule, Page 58) improper handling and need replacement, use WARNING...
  • Page 49: Front Glass Enclosure Panel, Removal And Installation

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ Front Glass Enclosure Panel, Removal Locate the two (2) latches at the top of the WARNING control compartment and disengage them from and Installation the door frame bottom vee-flange, pulling down Any safety screen, guard, or on their handles to open them.
  • Page 50: Install Vermiculite, Embers And Logs

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ INSTALL VERMICULITE, GLOWING EMBERS AND LOGS NOTE: It is important to ensure proper log placement per the manual when installing these units. Verify pilot flame is not obstructed. See Verifying Appliance Operation on Pages 31 and 32.
  • Page 51 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ LIBRAPF, LIBRAST, LIBRACL AND LIBRACR LOG PLACEMENT Log Number Description Log, Corner Log, Rear/Left Log, Front/Left Log, Rear/Right Log, Front/Center Log, Center/Top Catalog Number for the entire log set: 55M04 Log (3) Lays Over Logs 1 And 2 STEP 3...
  • Page 52 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ LIBRAPF, LIBRAST, LIBRACL AND LIBRACR LOG PLACEMENT (CONTINUED) Log Number Description Log, Corner Log, Rear/Left Log, Front/Left Log, Rear/Right Log, Front/Center Log, Center/Top Catalog Number for the entire log set: 55M04 Position The Round End Of Log (6) Against The Notch Of Log (4) Here.
  • Page 53: Burner Flame Appearance/Sooting

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ BURNER ADJUSTMENTS Air Shutter Adjustment Guidelines The following chart is provided to aid you in achieving the correct air shutter adjustment (QUALIFIED TECHNICIANS ONLY) • If there is smoke or soot present, first for your installation.
  • Page 54: Burner Flame Adjustments

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ BURNER FLAME ADJUSTMENTS Air Shutter MILLIVOLT Hood Igniter Rod Adjusting WARNINGS Thermocouple Orifice • Air shutter adjustment should only be performed by a quali- fied professional service tech- 3/8"...
  • Page 55: Wiring Diagrams

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ WIRING DIAGRAMS ATTENTION: AU MOMENT DE L'ENTRETIEN DES COMMANDES, ÉTIQUETEZ TOUS LES FILS AVANT DE LES DÉBRANCHER. DES ERREURS DE CÁBLAGE Wiring diagrams are provided here for reference PEU-VENT ENTRAÎNER UN FONCTIONNEMENT INADÉQUAT ET DANGEREUX.
  • Page 56: Accessory Components

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ ACCESSORY COMPONENTS Cost Effective Solution • Simple On/Off operation Flame and Heat modulation Kit includes: Thermostatic or Manual modes • Includes solenoid for SIT millivolt valves Remote and Receiver •...
  • Page 57 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ ACCESSORY COMPONENTS CONTINUED Bag of Glowing Embers Bag of Volcanic Stone Touch-Up Paint Kit Replacement ember materials or volcanic stone are OFF/ON Wall Switch Kit Repair of minor scratches and discoloration of the available for use with these appliances.
  • Page 58: Maintenance Schedule

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ MAINTENANCE SCHEDULE Annually (Before the onset of the Burning Season) MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE Inspecting/Cleaning Burner, Logs Qualified Service Technician Inspect valve and ensure it is properly operating. Check piping and Controls for leaks.
  • Page 59: Lighting Instructions - Millivolt

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ LIGHTING INSTRUCTIONS, MILLIVOLT - ENGLISH FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 60 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ LIGHTING INSTRUCTIONS, MILLIVOLT - FRENCH POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 61: Lighting Instructions - Electronic

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ LIGHTING INSTRUCTIONS, ELECTRONIC - ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 62 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ LIGHTING INSTRUCTIONS, ELECTRONIC - FRENCH POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 63: Troubleshooting Guide - Millivolt

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM NOTE: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in the “ON” position. IMPORTANT: Valve system troubleshooting should only be accomplished by a qualified service technician.
  • Page 64: Troubleshooting Guide - Electronic

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM NOTE: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
  • Page 65: Replacement Parts List

    Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ REPLACEMENT PARTS LIST Description Part No. LibraST LibraPF LibraCL LibraCR Hood (Black) 24" J7537 Hood (Black) 40" J7536 Glass Enclosure Assembly 24" H6336 Glass Enclosure Assembly 40" H8122 Log Set 55M04...
  • Page 66 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01, 05/2016 ™ REPLACEMENT PARTS LIST CONTINUED GAS CONTROLS — SIT MILLIVOLT Natural Propane DESCRIPTION Part No. Qty. Part No. Qty. Gas Valve - SIT H6209 88J53 Piezo Igniter 10K86 10K86 Pilot Assembly...
  • Page 67: Warranty

    Innovative Hearth Products Astria Brand Gas Fireplace ® Limited Lifetime Warranty THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria ® brand gas fi replace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and fi rebox carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 68 Innovative Hearth Products Installation and Operation Instructions Libra Series Direct-Vent Gas Fireplaces 900299-01 05/2016 ™ Astria.us.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name Innovative Hearth Products reserves the right to make changes at any time, with- out notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Table of Contents