Astria Fireplaces Sirius42TEN Installation And Operation Instructions Manual

Astria Fireplaces Sirius42TEN Installation And Operation Instructions Manual

Direct-vent gas fireplaces
Hide thumbs Also See for Sirius42TEN:

Advertisement

P/N 900079-00 REV. C 08/2016
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900079-01.
P900079-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by
a qualifi ed installer, service agency or the gas
supplier.
Installation and Operation Instructions
Sirius™ Direct-Vent Gas Fireplaces
Models
PFS
®
C
US
Report No. F14-108
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
Sirius42TEN
Sirius42TEP
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides infl ammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifi é
ou par le fournisseur de gaz.
Sirius54TEN
Sirius54TEP

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sirius42TEN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Astria Fireplaces Sirius42TEN

  • Page 1 Sirius™ Direct-Vent Gas Fireplaces P/N 900079-00 REV. C 08/2016 Models Ce manuel est disponible en francais, simplement ® en faire la demande. Numéro de la pièce 900079-01. Sirius42TEN Sirius54TEN Report No. F14-108 Sirius42TEP Sirius54TEP P900079-00 INSTALLER: Leave this manual with the appliance.
  • Page 2: General Information

    Innovative Hearth Products General Information Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 SAFETY AND YOUR FIREPLACE See attached color fl yer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.
  • Page 3 Innovative Hearth Products General Information Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 La sécurité et Safety and Your Seguridad y su votre foyer Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fi replace get chimenea IHP se ponen foyer IHP deviennent EXTRÊMEMENT CHAUDES !
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information. Following these safety, care, and operation instructions will help ensure many years of dependable and enjoyable service from your fi...
  • Page 5: Important Safety Information

    Innovative Hearth Products General Information Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 IMPORTANT SAFETY INFORMATION Important Safety Information L’information de sûreté Información importante de importante seguridad 1. WARNING: Do not operate appliance with the glass front removed, cracked 1. AVERTISSEMENT. Ne pas utiliser l’appareil or broken.
  • Page 6: Fireplace Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualifi...
  • Page 7 Innovative Hearth Products General Information Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 APPLIANCE OPERATION NOTICES These fi replaces are vented gas appliances. Do not burn wood or other material in these appliances. These appliances are designed to operate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous.
  • Page 8: Packaging

    Innovative Hearth Products General Information Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 INSTALLATION PACKAGING All models include The assembled vented gas fi replace heater is packaged with: • Literature Kit (Installation and Operation Instructions [this manual], Hot Glass Safety Flyer, and Safety-In-Operation Warning Labels) •...
  • Page 9 Innovative Hearth Products General Information Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Approved Vent Components These fi replaces are designed, tested and listed for operation and installation with the following vent components only: ® • Secure Vent Direct-Vent System Components, •...
  • Page 10 Innovative Hearth Products General Information Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Figure 1 - Electronic Gas Valve Green Wire (from DFC Wire Harness) Line (IN) Test Port Manifold (OUT) Test Port Orange Wire (from DFC Wire Pressure Harness) Regulator Tower Main Gas Inlet 3/8"...
  • Page 11: Requirements For The Commonwealth Of Massachusetts

    Innovative Hearth Products General Information Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Orifi ce Sizes—Sea Level to High Altitude These fi replaces are tested and approved for installation at elevations of 0–4500 ft (0–1372 m) above sea level using the standard burner orifi ce sizes (Table 5). For elevations above 4500 ft, contact your gas supplier or qualifi ed service technician.
  • Page 12: Manufactured Home Requirements

    Innovative Hearth Products General Information Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
  • Page 13: Vent Termination Clearances

    Innovative Hearth Products General Information Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 VENT TERMINATION CLEARANCES The following vent termination fi gures and charts should be used. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or the current standards of CAN/ CGA-B149.1 in Canada.
  • Page 14 Innovative Hearth Products General Information Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Table 7 - Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors Inside Corner Outside Corner Recessed Location See Table 6 Fixed Balcony with No Side Wall Balcony with Perpendicular Side Wall Openable Fixed Closed...
  • Page 15: Minimum Clearances To Combustibles

    Innovative Hearth Products General Information Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fi replace is approved with zero clearance to combustible materials on all sides (Table 8), with the following exceptions: •...
  • Page 16: Wall Finishes / Surrounds / Mantels

    Innovative Hearth Products General Information Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Wall Finishes / Surrounds / Mantels Clearances to combustible mantels vary according to mantel depth (Figure 7). Mantels constructed of non-combustible material may be installed at any height above the appliance opening; however, do NOT allow anything to hang below the top edge of the fi...
  • Page 17: Installation Sequence

    Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 INSTALLATION SEQUENCE The typical sequence of installation is outlined below; however, each installation is unique and may result in variations to the steps described. See the pages referenced in the following steps for detailed instructions. Framing 1.
  • Page 18 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 NOTE: Fireplace is designed for 1” thickness of non-combustible board on the face of the unit. If the fi nished surface is to match a thinner fi nish material the unit must be recessed up to 1/2”...
  • Page 19: Prepare The Fireplace Top Spacers

    Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Prepare the Fireplace Top Spacers 1. The two (2) 4-3/8” standoff spacers on top of the fi replace cabinet are shipped fl at (Figure 8). 2. Bend the standoffs as shown (Figure 8): 3.
  • Page 20: Vent System Preparation

    Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 • Check with the local building offi cial for local code requirements (e.g., Are below grade penetrations of the gas line allowed?, etc). CAUTION If propane is used, be aware that with a tank that is too small (i.e., under 100 lbs, if this is the only gas appliance in the dwelling—see NPFA 58), there may be a loss of pressure.
  • Page 21 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Figure 11 - When to use a vent restrictor Figure 12 - Vent restrictor installation, Top vent Base Position 1 Position 2 U-Shaped 60 ft Maximum vertical run Vent Vent Collar Restrictor...
  • Page 22 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 1. Align the dimpled end over the collar, adjusting the radial alignment until the four (4) locking dimples are aligned with the inlet of the four (4) inclined channels on the collar (Figure 14). 2.
  • Page 23 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Table 17 - Vent Section Length Nominal Section Nominal Section Length Length (in.) (in.) Net Section Length 10.5 22.5 34.5 46.5 Net Section Length (in.) 10.5 22.5 34.5 46.5 (in.) Height of Vent Height of Vent...
  • Page 24: Install The Vent System

    Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Clearance to combustibles Maintain the minimum clearance to combustibles (e.g., framing, attic, ceiling insulation, etc.). For all vertical runs: • 1” (26 mm) from all sides NOTE: Attic insulation shield (H3907) must be installed when blown or loose-fi ll insulation is used, and is recommended for all attic installations.
  • Page 25 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Vertical (Offset) Installation 1. Analyze the vent route and determine the number of vent sections and elbows required—See Effective Vent Length on Pages 22-23 for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists.
  • Page 26 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 7. Change vent direction of horizontal/inclined run—Install the SV4.5E45 and SV4.5E90 elbows in the same manner as the straight vent sections. See Vent elbows on Page 22 for more information. 8.
  • Page 27 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Vertical Vent Figures/Tables NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane of approximately 1/4” per 1 ft (20 mm per 1 m). NOTE: SV4.5VF (Secure Vent), SF4.5VF (Secure Flex) fi...
  • Page 28 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Table 19 - Top Vent—Two 90° Elbows Table 20 - Top Vent—Three Elbows Vertical Firestop/  Spacer Horizontal Firestop/  Spacer Vertical Firestop/   Spacer Horizontal  Firestop/ ...
  • Page 29 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 30 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 8. Change vent direction—At transition from or to a horizontal/inclined run, install SV4.5E45 or SV4.5E90 elbows in the same manner as the straight vent sections. The elbows feature a twist section to allow them to be routed about the center axis of their initial collar section to align with the required direction of the next vent run element.
  • Page 31 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Figure 24 - Installing the Horizontal Termination To help minimize water infi ltration Firestop/Spacer (SV4.5HF) shown Typical it is recommended that the Fire- Termination on the exterior side of the wall. It stop/ Spacer (SV4.5HF) be installed Shown may also be installed on the...
  • Page 32 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Table 21 - Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness Termination Kit Only 6 to 9-1/4” (152 to 235 mm) Termination Kit and 6”...
  • Page 33 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Table 23 - Top Vent—Two 90° Elbows Maximum total H Minimum total V Horizontal Horizontal Firestop/  Termination feet meters feet meters  Spacer 0.610 0.305 1.372 0.914 1.829 1.220 2.286 1.524...
  • Page 34 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Vertical or Horizontal Venting Using Secure Flex ® Kits and Components Secure Flex ® venting kits and components may be used in any other vent installation where rigid Secure Vent ®...
  • Page 35: Complete The Field Wiring

    Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 f. Install three (3) screws 120° apart through the fl exible vent and into the adaptor collar just below the gear clamp to provide additional security to the connection. 3.
  • Page 36 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 NOTE: The junction box can be moved to the bottom of the box (Figure 30). To move the junction box remove the cover plate, compress junction box to release it from the fi replace. Select the new location. For the bottom location, install the 3-wire 120 Vac supply wire and strain relief in the hole provided.
  • Page 37: Connect The Gas Line

    Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 WARNING Electronic models of these appliances are equipped with a three-prong (grounding) plug utilized in connecting the electronic components to the junction box in the lower compartment. This grounding plug provides protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
  • Page 38: Verify Proper Fireplace Operation

    Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 NOTE: Seal around the gas line to prevent cold air leakage. Gas line holes and other openings can be caulked or stuffed with unfaced fi berglass insulation. 1. Unscrew the shutoff valve from the gas fl ex-line. Apply thread sealant appropriate for the gas type, and then connect the shutoff valve to the gas stub.
  • Page 39: Install The Glass Media

    Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Install the Glass Media 1. See Page 55 for instructions on Installing the Glass Media. Install the Baffl e NOTE: The baffl e is factory-installed. Remove to install the vent restrictor (Page 20). 1.
  • Page 40 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Air Shutter Adjustment Guidelines • If there is smoke or soot present, fi rst ensure that the fl ames are not impinging on any of the panels. If the panels are properly positioned and a sooting condition still exists, increase the air shutter opening.
  • Page 41: Install The Finishing Materials

    Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Install the Finishing Materials NOTE: See Cold Climate Insulation on Page 11 and Vent Termination Clearances on Page 13. 1. Complete fi nished interior wall. Maintain a minimum 1” (26 mm) clearance from the door frame outer edge to any fi...
  • Page 42 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Figure 39 - Noncombustible Material with Surround— Figure 38 - Noncombustible Material with Cleanface Profi le View Finish—Profi le View * 6” straight vent section Insulation and combustible Min. 1" Min.
  • Page 43 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 9. Reinstall door and secure with three screws. 10. Install Gas Shutoff Valve Door (Figure 41). 11. Install barrier on barrier mounting brackets. Figure 40 - Gas Shutoff Valve Bracket Figure 41 - Installing the Surround Tab (bend up to hold valve)
  • Page 44: Install The Wall Switch Receiver

    Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Install the Wall Switch Receiver 1. When wall fi nish is complete, install the wall switch receiver in the previously installed junction box, and connect the 2-wire terminal to the connector on the back of the receiver. 2.
  • Page 45 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 INSTALLER - ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affi xed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD...
  • Page 46: Installation Accessories

    Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 INSTALLATION ACCESSORIES ® Table 27 - Listed Secure Vent Components Catalog Number Model Description Catalog Number Model Description The following fl ashing comes packaged with a storm collar Horizontal Square Termination with 77L78 SV4.5F...
  • Page 47 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 ® Table 28 - Listed Secure Vent Components Catalog Number Model Description Catalog Number Model Description Through Wall Attic Insulation Shield Shield Kit (to H3907 SV4.5ARSA with adjustable height, shield direct-vent 12–22”...
  • Page 48: Gas Conversion Kits

    Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 GAS CONVERSION KITS WARNING This conversion kit shall be installed by a qualifi ed service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fi...
  • Page 49 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Installing Gas Conversion Kits WARNING The gas supply shall be shut OFF prior to disconnecting the electrical power, before proceeding with the conversion. AVERTISSEMENT Avant d’effecteur la conversion, coupez d’abord l’alimentation en gaz, ensuite, coupez l’alimentation electrique.
  • Page 50 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 11. Make valve electrical connections. 12. Remove the pilot hood assembly to access the hex pilot orifi ce (Figure 47). Remove and replace the pilot orifi ce with the one provided with the kit. Exercise extreme care to prevent damage to or breakage of the igniter assembly.
  • Page 51: Operation

    Innovative Hearth Products Operation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.
  • Page 52 Innovative Hearth Products Operation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD À LA SÉCURITÉ D’UTILISATION EN OPERACIÓN Your fi...
  • Page 53 Innovative Hearth Products Operation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Burn-in Period The fi rst few times this fi replace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few days.
  • Page 54 Innovative Hearth Products Operation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Detailed lighting instructions are found on Pages 64-65. Also, electronic fi replace lighting instructions are attached to the CPI/IPI switch bracket. The fi replace main burner can be turned ON/OFF with the wall switch or remote control. Check the batteries, at least every three (3) months to ensure they are properly charged (Figure 2, Page 10).
  • Page 55 Innovative Hearth Products Operation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Continuous Pilot Ignition / Intermittent Pilot Ignition Switch These fi replaces have a continuous pilot ignition (CPI) / intermittent pilot ignition (IPI) switch installed under the door. This switch allows the pilot to be switched from intermittent mode to continuous mode: •...
  • Page 56 Innovative Hearth Products Installation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 2. Spread the glass media in a thin layer, evenly around the burner (Figure 51). Do NOT mound the media. Figure 51 - Installing the glass media Do NOT place media on burner or Glass media area around pilot.
  • Page 57 Innovative Hearth Products Operation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Installing and removing the glass door WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. • Remove glass door only when fi replace is OFF and COLD. •...
  • Page 58 Innovative Hearth Products Operation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Installing the glass door 1. Visually inspect the gasket on the backside of the glass door. NOTE: The gasket surface must be clean, free of irregularities, and seated fi rmly. Ensure it is properly located. Make sure the bead is not rolled into the channel at the top of the door, but remains fl...
  • Page 59: Maintenance

    Innovative Hearth Products Operation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 MAINTENANCE Refer to the Maintenance Schedule on Page 61 for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper fi replace operation after servicing. WARNING Turn OFF gas and electrical power to the fi...
  • Page 60 Innovative Hearth Products Operation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Inspecting the glass gasket Visually inspect the gasket on the backside of the glass door. The gasket surface must be clean, free of irregularities, and seated fi rmly. Cleaning the control compartment Keep the control compartment clean by vacuuming or brushing it out at least twice a year.
  • Page 61 Innovative Hearth Products Operation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Table 32 - Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By Procedure Inspecting/Cleaning Burner, Panels, and Qualifi...
  • Page 62: Optional Accessory Components

    Innovative Hearth Products Operation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 OPTIONAL ACCESSORY COMPONENTS Surround Kits Surround kits should be used for a fi nished appearance. Table 34 - Surround Kits Catalog No. Model No. Description F2261 LDV42-SB Black Satin, 42” models F2263 LDV42-SS Stainless Steel, 42”...
  • Page 63 Innovative Hearth Products Operation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Thermostatic Control Kits Feature a thermostatic ON/OFF mode as well as manual ON/OFF operation. Table 39 - Thermostatic Control Kits RC-S-Touch, State-of-the-art control with touch screen operation Catalog Number •...
  • Page 64: Lighting Instructions

    Innovative Hearth Products Operation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 LIGHTING INSTRUCTIONS - ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 65 Innovative Hearth Products Operation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 LIGHTING INSTRUCTIONS - FRENCH POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 66: Troubleshooting

    Innovative Hearth Products Operation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 TROUBLESHOOTING Before troubleshooting, ensure that the fi replace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the fi replace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 67: Replacement Parts

    Innovative Hearth Products Operation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 REPLACEMENT PARTS Contact an IHP dealer to obtain any of these parts. Contact IHP for the phone number of your nearest IHP dealer. Table 43 - Installer Replacement Parts 42”...
  • Page 68 Innovative Hearth Products Operation Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Figure 53 - Replacement Parts Table 44 - Homeowner Replacement Parts 42” 54” Description Catalog Number Catalog Number Remote Control Transmitter Kit, RCKIT4001 F2236 F2236 Glass Door H8799 H8431 Top Baffl...
  • Page 69: Warranty

    Innovative Hearth Products Astria ® Brand Gas Fireplace Limited Lifetime Warranty THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria ® brand gas fi replace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and fi rebox carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 70 Innovative Hearth Products Installation and Operation Instructions Sirius™ Linear Direct-Vent Gas Fireplaces 900079-00, 08/2016 Astria.us.com Record the following important information about your fi replace: Fireplace model number Fireplace serial number Date fi replace was Installed Type of gas fi replace uses Dealer name Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifi...