P/N 900684-00 REV. D 08/2018
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900684-04.
P900684-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Installation and Operation Instructions
Gemini™ Direct-Vent Gas Fireplaces
Models
C
US
Report No. F13-094
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
Gemini35DMN-B
Gemini40DMN-B
Gemini35DMP-B
Gemini40DMP-B
Gemini35DEN-B
Gemini40DEN-B
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
Gemini45DEN-B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Gemini35DMN-B and is the answer not in the manual?

Questions and answers

Eileen Robinson
February 12, 2025

I have had this fireplace for 7 years and not realize that there was a need to clean the glass now the glass has a white hue on it. I hesitate to remove the glass not sure if I will be able to get it back in properly. Is the glass cleanable at this point? Who do I call to do this or to replace the glass?

1 comments:
Mr. Anderson
February 12, 2025

Yes, the glass on an Astria Fireplaces Gemini35DMN-B can be cleaned if it has a white hue. The white coating may result from impurities and minerals in the fuel. Approved cleaning solutions include non-ammonia-based glass cleaner, a 50/50 mixture of white vinegar and water, or gas fireplace/stove glass cleaner. The manual does not specify a contact for cleaning or replacement.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Astria Fireplaces Gemini35DMN-B

  • Page 1 Installation and Operation Instructions Gemini™ Direct-Vent Gas Fireplaces P/N 900684-00 REV. D 08/2018 Models Gemini35DMN-B Gemini40DMN-B Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 900684-04. Gemini35DMP-B Gemini40DMP-B Gemini45DEN-B Gemini35DEN-B Report No. F13-094 Gemini40DEN-B P900684-00 INSTALLER: Leave this manual with the appliance.
  • Page 2: General Information

    Innovative Hearth Products General Information Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 SAFETY AND YOUR FIREPLACE See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is pro- vided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3 Innovative Hearth Products General Information Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 La sécurité et Safety and Your Seguridad y su votre foyer Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fireplace get chimenea IHP se ponen foyer IHP deviennent EXTRÊMEMENT CHAUDES !
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Traditional - Forest Oak Logs THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
  • Page 5: Important Safety Information

    Innovative Hearth Products General Information Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 IMPORTANT SAFETY INFORMATION Important Safety Informa- L’information de sûreté Información importante de tion importante seguridad 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked si le panneau frontal en verre n’est pas en frente de vidrio quitado, agrietado o roto.
  • Page 6: Fireplace Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
  • Page 7 Innovative Hearth Products General Information Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 APPLIANCE OPERATION NOTICES These fireplaces are vented gas appliances. Do not burn wood or other material in these appliances. These appliances are designed to operate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous.
  • Page 8: Packaging List

    Innovative Hearth Products General Information Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 INSTALLATION PACKAGING All models include The assembled vented gas fireplace heater is packaged with: • Literature Kit (envelope in bottom compartment containing Installation and Operation Instructions (this manual), Hot Glass Safety Flyer, and Safety-In-Operation Warning Labels) •...
  • Page 9 Innovative Hearth Products General Information Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Approved Vent Components These fireplaces are designed, tested and listed for operation and installation with the following vent components only: • Secure Vent Direct-Vent System Components, ® • Secure Flex Flexible Vent Components, and ®...
  • Page 10: Gas Pressure

    Innovative Hearth Products General Information Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Gas Pressure Table 3 - Inlet Gas Supply Pressure Fuel Minimum Maximum Natural Gas 5” WC / (1.25 kPa) 10.5” WC / (2.61 kPa) Propane 11.0” WC / (2.74 kPa) 13.0”...
  • Page 11: Requirements For The Commonwealth Of Massachusetts

    Innovative Hearth Products General Information Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Orifice Sizes—Sea Level to High Altitude These fireplaces are tested and approved for installation at elevations of 0–4500 ft (0–1372 m) above sea level using the standard burner orifice sizes (Table 5). For elevations above 4500 ft, contact your gas supplier or qualified service technician.
  • Page 12: Manufactured Home Requirements

    Innovative Hearth Products General Information Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
  • Page 13: Vent Termination Clearances

    Innovative Hearth Products General Information Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 VENT TERMINATION CLEARANCES These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 14 Innovative Hearth Products General Information Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Table 7 - Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors Inside Corner Outside Corner Recessed Location See Table 6 Fixed Balcony with No Side Wall Balcony with Perpendicular Side Wall Openable Fixed Closed...
  • Page 15: Minimum Clearances To Combustibles

    Innovative Hearth Products General Information Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fireplace is approved with zero clearance to combustible materials on all sides (Table 8), with the following exception: The unit may not be recessed (allowance made for mantel legs / side trim in (Figure 6). When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit (Figure 6).
  • Page 16: Wall Finishes / Surrounds / Mantels

    Innovative Hearth Products General Information Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Figure 6 - Combustible Side Clearances Figure 7 - Mantel Height At 6” minimum side wall Mantel depth At 6 in. minimum clearance, a 20 (508) side wall clearance, combustible wall Top View of Top View of...
  • Page 17: Installation Sequence

    Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 INSTALLATION SEQUENCE The typical sequence of installation is outlined below; however, each installation is unique and may result in variations to the steps described. See the pages referenced in the following steps for detailed instructions. Framing 1.
  • Page 18 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Table 10 - Fireplace Framing Specifications NOTE: Dimension “D” is the Framing required framing depth when 10-1/2 Model construction to be (267) the finish material (drywall) 2 x 4, or larger. thickness is 1/2”...
  • Page 19: Prepare The Fireplace Top Spacers

    Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Prepare the Fireplace Top Spacers 1. The two (2) 4” standoff spacers on top of the fireplace cabinet are shipped flat. Remove the screw adjacent to the detached end (Figure 8). 2.
  • Page 20: Determining Vent Setup In The Combination Venting Unit

    Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Determining Vent Setup in the Combination Venting Unit Combination venting units are shipped with rear venting setup nearly ready for install. If this is the type of vent you require, remove all insulation packing and flue plug block off from rear venting and proceed with fireplace installation.
  • Page 21: Installing Non-Combustible Fireboard Standoff

    Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Installing Non-Combustible Fireboard Standoff - All Models A non-combustible standoff board is provided for all model fireplaces to prevent overlap of drywall or other material of portions of the fireplace that may be prone to the buildup of heat.
  • Page 22: Place The Fireplace In The Framing And Secure

    Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Place the Fireplace in the Framing and Secure NOTE: Nailing flanges, combustible members, and screw heads in areas directly adjacent to the nailing flanges are EXEMPT from the 1/2” clearance to combustible requirements for the firebox outer wrapper. NOTE: Combustible framing may be in direct contact with the nailing flanges and may be located within 1/2”...
  • Page 23 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Install the Vent Restrictor (if necessary) 1. Use the vent run descriptions in Figure 12 to determine if a vent restrictor is necessary. 2. If necessary, assemble the vent restrictor and wing as detailed in Figures 12 and 15. 3.
  • Page 24 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Vent Restrictor with Horizontal Terminations When horizontally terminating a vent system with a vertical vent run up to 4 ft through an exterior wall, no vent restrictor is required. If installing more than 4 ft of vertical venting, install the restrictor (Figure 14, Page 23), from inside or outside the unit, in the inner fireplace collar.
  • Page 25 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Vent section length table Table 14 will assist calculating how many vent sections are needed for the planned vent configuration. When a vent section is engaged with another section, its effective length will be 1-1/2” shorter. Table 14 - Vent Section Length Nominal Section Nominal Section Length...
  • Page 26: Install The Vent System

    Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Clearance to combustibles Maintain the minimum clearance to combustibles (e.g., framing, attic, ceiling insulation, etc.). For all vertical runs: • 1” (26 mm) from all sides NOTE: Attic insulation shield (H3907, see Page 47) must be installed when blown or loose-fill insulation is used, and is required for all attic installations.
  • Page 27 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Vertical (Offset) Installation 1. Analyze the vent route and determine the number of vent sections and elbows required—See Effective Vent Length on Pages 24-25 for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists.
  • Page 28 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 8. Continue installation of horizontal/inclined sections—Continue with the installation of the straight vent sections in horizontal/inclined run. Install support straps every 5 ft (1.52 m) along horizontal/inclined vent runs using conventional plumber’s tape in a direction away from the fireplace.
  • Page 29 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Vertical Vent Figures/Tables NOTE: Secure Vent rigid vent pipe is shown in the figures; Secure Flex flexible vent pipe may also be used. ® ® NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane of approximately 1/4”...
  • Page 30 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Table 17 - Top Vent—Two 90° Elbows Table 18 - Rear Vent—Three Elbows Table 19 - Top Vent—Three Elbows When using Secure Flex , use ® ceiling firestop/ spacer SF4.5VF. Ceiling firestop/ When using spacer SV4.5VF...
  • Page 31 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 32 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 6. Install the firestop/spacer at the ceiling—When using Secure Vent , use SV4.5VF firestop/spacer at ceiling ® joists; when using Secure Flex , use SF4.5VF firestop/spacer. If there is living space above the ceiling level, ®...
  • Page 33 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Figure 26 - Installing the Horizontal Termination To help minimize water infiltration Firestop/Spacer (SV4.5HF) shown Typical it is recommended that the Fire- Termination on the exterior side of the wall. It stop/ Spacer (SV4.5HF) be installed Shown may also be installed on the...
  • Page 34 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Table 20 - Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness Termination Kit Only 6 to 9-1/4” (152 to 235 mm) Termination Kit and 6”...
  • Page 35 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Table 23 - Top Vent—One 90° Elbow, Elbow Connection NOT at Fireplace H Maximum V Minimum feet meters feet meters 1.524 0.305 3.048 0.610 4.572 0.914 Ceiling firestop/ 7.62 1.524 Min.
  • Page 36 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Table 26 - Rear Vent—Three 90° Elbows H + H Maximum H Maximum V Minimum Wall firestop/spacer Wall Firestop/Spacer feet meters feet meters feet meters SV4.5HF ** SV4.5HF** 1.524 0.610 0.305 3.048...
  • Page 37 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Vertical or Horizontal Venting Using Secure Flex Kits and Components ® Secure Flex venting kits and components may be used in any other vent installation where rigid Secure Vent ®...
  • Page 38: Complete The Field Wiring

    Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 e. Slide the gear clamp down and tighten it fully to secure the flexible vent to the adaptor outer collar approximately 3/4” from the end of the flexible vent. f.
  • Page 39 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 NOTE: The supplied 15 ft of 2-conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed loose inside the bottom compartment. CAUTION In millivolt systems, do NOT connect a wall switch to a 120 V power supply.
  • Page 40: Install The [Optional] Blower Kit After Installation In The Framing

    Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 6. If a wall-mounted ON/OFF control, High/Low switch, or thermostat is to be used, mount it in a convenient location on a wall near the fireplace. 7. If an optional control is to be used, wire it in the low voltage circuit (Figure 32). NOTE: The supplied 15 ft of 2-conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed loose inside the bottom compartment.
  • Page 41: Connect The Gas Line

    Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Figure 31 - Junction Box Wiring, 120 V, 60 hz, 1 phase Figure 32 - Wiring Diagram—Millivolt Gas Valves Wall-mounted ON/ THERMOPILE OFF blower switch APPLIANCE- MOUNTED or variable speed ON/OFF SWITCH (OPTIONAL) control switch...
  • Page 42: Verify Proper Fireplace Operation

    Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resistant compounds are used in propane applications). Optionally, seal around the gas line to prevent cold air leakage. Gas line holes and other openings can be caulked or stuffed with unfaced fiberglass insulation.
  • Page 43: Optional: Install The Firebox Liners

    Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Optional: Install the Firebox Liners 1. See Page 54 for instructions on Traditional Only: Installing the Firebox Liners. Install the Logs, Volcanic Stone, and Glowing Embers 1. See Page 55 for instructions on Installing the logs, volcanic stone, and glowing embers. Install the Glass Door 1.
  • Page 44: Install The Hood

    Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Figure 37 - Air Shutter Adjustment Rod Table 28 - Air Shutter Adjustment Guidelines Adjustment Amount of Primary Flame Color Air Shutter Adjustment Set-Screw Adjustment If air shutter is Flame will Air shutter gap should be increased Rod Up...
  • Page 45: Install The Finishing Materials

    Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 NOTE: To install the hood after installing the non-combustible finish material over the black surface above the fireplace opening, the bottom edge of the finish material must be 5/8” above the top edge of the hood to allow clearance for installation and removal of the hood.
  • Page 46 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 INSTALLER - ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD...
  • Page 47: Installation Accessories

    Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 INSTALLATION ACCESSORIES IMPORTANT NOTE: The installation accessories shown in this section are part of the safety agency listing for the product models represented in this manual. Listed Secure Vent Components ®...
  • Page 48 Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 INSTALLATION ACCESSORIES (continued) IMPORTANT NOTE: The installation accessories shown in this section are part of the safety agency listing for the product models represented in this manual. Listed Secure Vent Components ®...
  • Page 49: Gas Conversion Kits

    Innovative Hearth Products Installation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 GAS CONVERSION KITS WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion, or the production of carbon monoxide may result;...
  • Page 50: Operation

    Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.
  • Page 51 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD À LA SÉCURITÉ D’UTILISATION EN OPERACIÓN Your fireplace has been furnished with safety instruc- tion labels that are to be affixed to the operation and Votre foyer a été...
  • Page 52 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Burn-in Period The first few times this fireplace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few days.
  • Page 53 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 If the millivolt fireplace is equipped with an optional remote switch (wall switch, remote control, rocker switch, or wall thermostat) and the pilot is lit, the fireplace main burner can be turned ON/OFF using the optional switch. NOTE: Do NOT wire more than one valve to the burner control switch.
  • Page 54 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Continuous Pilot Ignition Switch Fireplaces with an electronic gas valve have a continuous pilot ignition (CPI) switch installed in the control compartment. This switch allows the pilot to be switched from intermittent mode to continuous mode: •...
  • Page 55 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Installing the volcanic stone, and glowing embers (traditional models) WARNING • Turn OFF all gas and electricity to the appliance before installing the volcanic stone, embers, and logs. • Do NOT install the logs until the appliance has been completely installed, the gas line connected and tested for leaks, and the initial burner operation has been confirmed.
  • Page 56 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Installing the Gemini™ 33/35 Series Forest Oak Logs The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between flame peaks, so they do not impinge the flames.
  • Page 57 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Installing the Gemini™ 33/35 Series Forest Oak Logs (continued) 4. Position the Left Log (2) on log placement tab shown in Figure 46. The front of the log (2) straddles the farthest left grate leg as shown in Figure 50.
  • Page 58 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Installing the Gemini™ 40/45 Series Forest Oak Logs The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between flame peaks, so they do not impinge the flames.
  • Page 59 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Installing the Gemini™ 40/45 Series Forest Oak Logs (continued) Figure 55 - Place log #2 Figure 56 - Place log #3 Pin for Log #3 Bottom of Hole corresponds Groove log #3 Holes corresponds...
  • Page 60 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Installing and removing the glass door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage—Do not scratch or handle roughly while reinstalling the glass door frame.
  • Page 61 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Installing the glass door 1. Visually inspect the gasket on the backside of the glass door. NOTE: The gasket surface must be clean, free of irregularities, and seated firmly. Ensure it is properly located. Make sure the bead is not rolled into the channel at the top of the door, but remains flat against the top of the glass.
  • Page 62: Maintenance

    Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 MAINTENANCE Refer to the Maintenance Schedule on Page 64 for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper fireplace operation after servicing. WARNING Turn OFF gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
  • Page 63 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Inspecting the glass gasket Visually inspect the gasket on the backside of the glass door. The gasket surface must be clean, free of irregularities, and seated firmly. Cleaning the control compartment Keep the control compartment clean by vacuuming or brushing it out at least twice a year.
  • Page 64 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By Procedure Inspecting/Cleaning Burner, Logs Qualified Service Technician Inspect valve and ensure it is properly operating.
  • Page 65: Accessory Components

    Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 ACCESSORY COMPONENTS Forced Air Kits The FBK-100 blower provides constant velocity forced air circulation. The FBK-200 assembly with variable speed, wall-mountable switch provides variable speed forced air circulation. The FBK-250 offers variable speed control and a heat-activated switch;...
  • Page 66 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 ACCESSORY COMPONENTS (continued) Thermostatic Control Kit - Millivolt Models Feature a thermostatic ON/OFF mode as well as manual ON/OFF operation. RC-S-Touch, State-of-the-art control with touch screen operation Catalog Number •...
  • Page 67 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 ACCESSORY COMPONENTS (continued) Unit-Mountable Rocker Switch Kit - Millivolt Models This rocker switch kit can be installed directly in the control compartment to provide ON/OFF operation in lieu of a wall switch.
  • Page 68 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 ACCESSORY COMPONENTS (continued) Variable Speed Wall Switch Kit The variable speed wall switch kit provides variable speed control if the optional FBK-100 blower kit is installed. Catalog Model 045571H VSWS...
  • Page 69: Lighting Instructions

    Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 LIGHTING INSTRUCTIONS, MILLIVOLT - ENGLISH FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 70 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 LIGHTING INSTRUCTIONS, MILLIVOLT - FRENCH POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 71 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 LIGHTING INSTRUCTIONS, ELECTRONIC ECOFLOW - ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 72 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 LIGHTING INSTRUCTIONS, ELECTRONIC ECOFLOW - FRENCH POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 73: Troubleshooting

    Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 TROUBLESHOOTING MILLIVOLT SYSTEMS Before troubleshooting, ensure that the fireplace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the fireplace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 74 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 TROUBLESHOOTING ELECTRONIC SYSTEMS SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Nothing happens a. Remote is not functioning properly. Check that the wall switch plate is set to REMOTE. when the fireplace is Operate the fireplace from the wall plate switch.
  • Page 75: Replacement Parts

    Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 REPLACEMENT PARTS 33” Models 35” Models 40” Models 45” Models Catalog Catalog Catalog Catalog Number Number Number Number Millivolt, Pilot Assembly, Natural Gas 69L17 69L17 69L17 69L17 Millivolt, Pilot Assembly, Liquid Propane 69L18 69L18 69L18...
  • Page 76 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 REPLACEMENT PARTS (continued) 33” Models 35” Models 40” Models 45” Models Catalog Catalog Catalog Catalog Number Number Number Number ECOFLOW PARTS Pilot Assembly, Ecoflow, Natural Gas J7935 J7935 J7935 J7935 Pilot Assembly, Ecoflow, Liquid Propane J7962...
  • Page 77 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 REPLACEMENT PARTS (continued) Cat. No. Model Description F2991 Gemini35DMN-B 35” DV, MV, Top/Rear Vent F2992 Gemini35DMP-B 35” DV, MV, Top/Rear Vent F2993 Gemini35DEN-B 35” DV, Elec, Top/Rear Vent F2987 Gemini40DMN-B 40”...
  • Page 78 Innovative Hearth Products Operation Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 NOTES NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...
  • Page 79: Warranty

    Innovative Hearth Products Astria Brand Gas Fireplace ® Limited Lifetime Warranty THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria brand gas fireplace ("Product") to be free from defects in materials and workmanship ® at the time of manufacture. The product body, firebox and barrier carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 80 Innovative Hearth Products Installation and Operation Instructions Gemini™ Series Direct-Vent Gas Fireplaces 900684-00D 08/2018 Astria.us.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name Innovative Hearth Products (IHP) reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.