Checking The Airflow; System Fans; Optional Fan Configurations - Supermicro SUPERSERVER 2028TP-DTR User Manual

Table of Contents

Advertisement

6-5

Checking the Airflow

Checking Airflow
1. Make sure there are no objects obstructing the airflow in and out of the
chassis. In addition, if you are using a front bezel, make sure the bezel's filter
is replaced periodically.
2. Except for brief periods while swapping hard drives, do not operate the server
without drives or the drive carriers in the drive bays. Use only recommended
server parts.
3. Make sure no wires or foreign objects obstruct airflow through the chassis.
Pull all excess cabling out of the airflow path or use shorter cables.
4. The control panel LEDs inform you of system status. See "Chapter 3: System
Interface" for details on the LEDs and the control panel buttons.
6-6

System Fans

Four fans provide cooling for the chassis. These fans circulate air through the
chassis as a means of lowering the chassis internal temperature. The SC217HD+
system fans are easy to change modules. There is no need to uninstall any
other parts inside the system when replacing fans, and no tools are required for
installation.

Optional Fan Configurations

The SC217HD+ model chassis is designed so that the default configuration of
the system is for each serverboard to control two fans. Each serverboard node in
the chassis is connected to the backplane through the adapter card, mounted in
the serverboard node drawer. In the event that one of the serverboard drawers is
removed, then the remaining serverboard will operate both fans.
Fan Configurations Options
SC217HD+ Hot-Swappable Default Configuration
Fans A and B connected to backplane,
backplane connected to Node A and B by adapter card
Fans C and D connected to backplane,
backplane connected to Nodes A and B by adapter card
6-5
Chapter 6: Advanced Chassis Setup

Advertisement

Table of Contents
loading

This manual is also suitable for:

Superserver 2028tp-dttrSuperserver 2028tp-dtfr

Table of Contents