SuperServer 2028R-C1R(T)4+ Quick Reference Guide
Board Layout
1
2
3
4
5
6
7
8
9
COM1
IPMI_LAN
UID
LAN3/4
LAN1/2
LE1
JUIDB1
USB4/5
LAN CTRL
LAN CTRL
(3.0)
USB 0/1
JIPMB1
CLOSE 1st
LEDM1
CPU2
BMC
BIOS
JBAT1
OPEN 1st
21
X10DRC/i-LN4+(-T4+)
JSD1
Intel PCH
SP1
20
JP
CLOSE 1st
JBT1
CPU1
19
OPEN 1st
18
LSI 3108
JS39
T-SGPIO1
SAS CTRL
T-SGPIO2
S-SGPIO1
FANB
Front CTRL Panel
16
13
17
15
14
No.
Description
CPU2 Slot1 PCI-E 3.0 x8
1
2
CPU2 Slot2 PCI-E 3.0 x8
CPU1 Slot3 PCI-E 3.0 x16
3
CPU2 Slot4 PCI-E 2.0 x4 (in x8)
4
CPU2 Slot5 PCI-E 3.0 x16
5
6
CPU2 Slot6 PCI-E 3.0 x8
7
DIMME1(Blue)/DIMME2/DIMME3 slot
8
DIMMF1(Blue)/DIMMF2/DIMMF3 slot
CPU2
9
DIMMH1(Blue)/DIMMH2/DIMMH3 slot
10
11
DIMMG1(Blue)/DIMMG2/DIMMG3 slot
12
DIMMA1(Blue)/DIMMA2/DIMMA3 slot
13
DIMMB1(Blue)/DIMMB2/DIMMB3 slot
14
CPU1 (Install CP1 first)
15
DIMMD1(Blue)/DIMMD2/DIMMD3 slot
16
DIMMC1(Blue)/DIMMC2/DIMMC3 slot
17
SAS 0~3 & SAS 4~7: SAS 3.0 connections supported by the LSI 3108 controlller
18
JBT1: Clear CMOS
19
JSD1: SATA DOM (Device on Module) Power Connectors
20
(I-)SATA 0~5: SATA 3.0 supported by Intel PCH (I-SATA 0~5)
21
(S)SATA 0~3: SATA 3.0 supported by Intel SCU (S-SATA 0~3)
Memory
Processors and their Corresponding Memory Modules
10
11
Corresponding DIMM Modules
CPU#
CPU 1
A1
A2
A3
B1
B2
CPU 2
E1
E2
E3
F1
F2
Processor and Memory Module Population for Optimal Performance
Number of
CPUs+DIMMs
(For memory to work properly, please follow the instructions below.)
1 CPU &
CPU1
2 DIMMs
P1-DIMMA1/P1-DIMMB1
1 CPU &
CPU1
4 DIMMs
P1-DIMMA1/P1-DIMMB1, P1-DIMMC1/P1-DIMMD1
1 CPU &
CPU1
5~8 DIMMs
P1-DIMMA1/P1-DIMMB1, P1-DIMMC1/P1-DIMMD1 + Any memory pairs in P1-
DIMMA2/P1-DIMMB2/P1-DIMMC2/P1-DIMMD2 slots
2 CPUs &
CPU1 + CPU2
4 DIMMs
P1-DIMMA1/P1-DIMMB1, P2-DIMME1/P2-DIMMF1
2 CPUs &
CPU1 + CPU2
6 DIMMs
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1
2 CPUs &
CPU1 + CPU2
8 DIMMs
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2-DIMMG1/P2-DIMMH1
1
2 CPUs &
CPU1/CPU2
8~16 DIMMs
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2-DIMMG1/
P2-DIMMH1 + Any memory pairs in P1, P2 DIMM slots
FAN1
2 CPUs &
CPU1/CPU2
16 DIMMs
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2-DIMMG1/P2-DIMMH1,
12
P1-DIMMA2/P1-DIMMB2/P1-DIMMC2/P1-DIMMD2, P2-DIMME2/P2-DIMMF2/P2-DIMMG2/P2-DIMMH2
2 CPUs &
CPU1/CPU2
16~24 DIMMs
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2-DIMMG1/P2-DIMMH1,
P1-DIMMA2/P1-DIMMB2/P1-DIMMC2/P1-DIMMD2, P2-DIMME2/P2-DIMMF2/P2-DIMMG2/P2-DIMMH2,
P1-DIMMA3/P1-DIMMB3/P1-DIMMC3/P1-DIMMD3, P2-DIMME3/P2-DIMMF3/P2-DIMMG3/P2-DIMMH3
DIMM Module Population Configuration
DDR4 Memory POR for Haswell-EP
DIMM Capacity
Ranks Per
(GB)
1 Slot Per
DIMM and
Type
Channel
Data Width
4Gb
8Gb
RDIMM
SRx4
8GB
16GB
RDIMM
SRx8
4GB
8GB
8GB
16GB
RDIMM
DRx8
RDIMM
DRx4
16GB
32GB
LRDIMM
QRx4
32GB
64GB
†
8Rx4
64GB 128GB
LRDIMM2DS
Beep Codes
Beep Code/LED
Error Message
1 beep
Refresh
5 short beeps + 1 long beep
Memory error
5 beeps
No Con-In or No Con-
Out devices
1 beep per device
Refresh
B3
C1
C2
C3
D1
D2
D3
F3
G1
G2
G3
H1
H2
H3
Speed (MT/s); Voltage (V);
Slot Per Channel (SPC) and DIMM Per Channel (DPC)
2 Slots Per
3 Slots Per
Channel
Channel
1DPC
1DPC
2DPC
1DPC
2DPC
3DPC
1.2V
1.2V
1.2V
1.2V
1.2V
1.2V
2133
2133
1866
2133
1866
1600
2133
2133
1866
2133
1866
1600
2133
2133
1866
2133
1866
1600
2133
2133
1866
1866
1600
2133
2133
2133
2133
2133
2133
1600
2133
2133
2133
2133
2133
1600
Description
Ready to boot
No memory detected in the system
Con-In includes USB or PS/2 keyboard, PC or
Serial Console Redirection, IPMI KVM or SOL.
Con-Out includes Video Controller, PCI or Serial
Console Redirection, IPMI SOL
1 beep or each USB device detected
Front View & Interface
HDD0~7
HDD8~15
3
4
1
5
8
6
9
2
7
10
No.
Description
Screw #B
1
Hard Drive Signal
2
Hard Drive Fail
3
Power Button
4
Reset Button
5
Device Activity LED
6
LAN1 LED
Screw #C
7
Overheat & Fan Fail LED
8
Power LED
9
LAN2 LED
10
Power Failure LED
1. Place heatsink on top of installed CPU
2. Line up the four screws to socket
3. Push down heatsink and screw down as shown
Rear View
4. NOTE: Only use 6-8 lb/f of torque; otherwise, hand-tighten
8
7
6
5
4
3
2
1
No.
Description
1
PCI Expansion Slots
2
UID Button
3
VGA Port
4
LAN 1/2/3/4 Ports
USB 0/1/2/3 Ports
5
Dedicated LAN for IPMI
6
COM Port
7
Redundant Power Supply Modules
8
http://www.supermicro.com
CPU Installation
Align CPU to socket;
install CPU straight down
!
NOTE:
Do not bend pin inside socket
Heatsink Installation
Screw #A
Screw #D
(cross pattern, in order: A, C, B, D)
each screw, to avoid damaging the system
Caution
!
SAFETY INFORMATION
IMPORTANT: See installation instructions and safety warning
before connecting system to power supply.
http://www.supermicro.com/about/policies/safety_information.cfm
!
WARNING:
To reduce risk of electric shock/damage to equipment,
disconnect power from server by disconnecting all power
cords from electrical outlets.
If any CPU socket empty, install protective plastic CPU cap
!
CAUTION:
Always be sure all power supplies for this system have
the same power output. If mixed power supplies are
installed, the system will not operate.
For more information go to :
http://www.supermicro.com/support
MNL-1595- QRG
ÌMNL-1595-QRG=Î
Need help?
Do you have a question about the SuperServer 2028R-C1R(T)4+ and is the answer not in the manual?
Questions and answers