Page 1
Instruction Manual P7350 5 GHz Differential Probe 071-1238-00 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to all safety summaries prior to performing service.
Page 3
Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
Preface This is the Instruction Manual for the P7350 differential probe. This manual provides operating information, specifications, and a replaceable parts list. P7350 5 GHz Differential Probe Instruction Manual...
This phone number is toll free in North America. After office hours, please leave a voice mail message. Outside North America, contact a Tektronix sales office or distributor; see the Tektronix web site for a list of offices. P7350 5 GHz Differential Probe Instruction Manual...
Do Not Operate With Suspected Failures. If you suspect there is damage to this product, have it inspected by qualified service personnel. Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry. P7350 5 GHz Differential Probe Instruction Manual...
Page 10
WARNING indicates an injury hazard not immediately accessible as you read the marking. CAUTION indicates a hazard to property including the product. Symbols on the Product. These symbols may appear on the product: CAUTION Refer to Manual P7350 5 GHz Differential Probe Instruction Manual...
Service Safety Summary and the General Safety Summary before performing any service procedures. Do Not Service Alone. Do not perform internal service or adjustments of this product unless another person capable of rendering first aid and resuscitation is present. P7350 5 GHz Differential Probe Instruction Manual...
Getting Started The P7350 is a high-bandwidth (5 GHz typical), active differential probe with a miniaturized probe head design. The probe has low circuit loading, high common-mode rejection, and ships with a variety of accessories for connecting to surface-mount devices and other components.
See Figure 2. To release the probe from the host instrument, grasp the compensa- tion box, press the latch button, and pull out the probe. Latch button Figure 2: Connecting and disconnecting the probe P7350 5 GHz Differential Probe Instruction Manual...
Y-lead adapter to the square pin adapter. Plug the SMT KlipChips into the Y-lead adapter. 4. Connect the SMT KlipChips to the PROBE COMPENSATION connections on the oscilloscope. 5. Adjust the oscilloscope to display a stable calibration waveform. P7350 5 GHz Differential Probe Instruction Manual...
9. Adjust the probe offset. The displayed waveform should vary between approximately +1.25 V and - - 1.25 V. Options The following options are available when ordering the P7350 probe: H Option D1- - Calibration Data Report H Option D3- - Calibration Data Report, 3 years (with Option C3)
Getting Started Features and Standard Accessories Table 1 shows the features and standard accessories of the P7350 differential probe. Table 1: P7350 features and standard accessories Feature/Accessory Description TekConnect interface. The TekConnect interface provides a communication path between the probe and the oscilloscope.
Page 18
Getting Started Table 1: P7350 features and standard accessories (Cont.) Feature/Accessory Description Variable spacing adapter (4 ea). The variable spacing adapter fits over the probe tip. Push the adapter onto the probe tip until it seats against the probe head.
Page 19
Getting Started Table 1: P7350 features and standard accessories (Cont.) Feature/Accessory Description TwinFoot adapter (4 ea). Use the TwinFoot adapter to probe two adjacent leads on a surface-mount integrated circuit. The TwinFoot adapter connects to the probe through the square pin adapter.
Page 20
Getting Started Table 1: P7350 features and standard accessories (Cont.) Feature/Accessory Description Cable marker bands Cable marker bands (10 ea). Attach matching pairs of the marker bands onto the cable at the head and compensation box of each probe. The marker bands enable quick verification of which probe is connected to which instrument channel.
Tektronix part number: 067-0422-XX Probe calibration fixture. Use the probe calibration fixture to perform some of the calibration procedures. The calibration fixture connects to signal sources used to test the probe characteristics. Tektronix part number: 067-0419-XX P7350 5 GHz Differential Probe Instruction Manual...
(CMRR), see the Reference section on page 17. The P7350 probe design is optimized for high bandwidth, low capacitance applications; it is not a general purpose probe. The probe head and tips are miniaturized for electrical characteristics and access to dense circuitry, and must be handled carefully.
The maximum input voltage is the maximum voltage to ground that the inputs can withstand without damaging the probe input circuitry. CAUTION. To avoid damaging the inputs of the P7350 differential probe, do not apply more than ±15 V (DC + peak AC) between each input and ground.
Figure 5: Using the variable spacing adapter IC leads being probed TwinFoot adapter Square pin adapter Conductive side of probe tip Probe Insulated side of probe tip Figure 6: Using the TwinFoot adapter P7350 5 GHz Differential Probe Instruction Manual...
When you connect the probe inputs to a circuit, you are introducing a new resistance, capacitance, and inductance into the circuit. Each input of the P7350 differential probe has a characteristic input impedance of 50 kΩ to ground in parallel with less than 0.4 pF. See Figure 7.
There are some applications that may require a ground reference connection to maintain measurement accuracy. Generally this is necessary when probing circuits which are fully isolated from ground, such as battery operated devices. P7350 5 GHz Differential Probe Instruction Manual...
The recommended method for hands-free probing is to use the probe only (without adapters), with a probe positioner such as a Tektronix PPM100 or PPM203B. If you need a tip space between 0.020 and 0.180 inches apart, use the variable spacing adapter and the probe...
Voltage that is common to both inputs is often referred to as the Common-Mode Voltage (V ) and voltage that is different as the Differential-Mode Voltage (V P7350 5 GHz Differential Probe Instruction Manual...
CMRR generally is highest (best) at DC and degrades with increasing frequency. Assessing CMRR Error Figure 12 on page 24 shows the CMRR of the P7350 differential probe. This derating chart assumes a common-mode signal that is sinusoidal. P7350 5 GHz Differential Probe Instruction Manual...
Figure 11 on page 20. Twisting the input leads together does increase capacitance that may degrade high-frequency performance. You should take into account any effects caused by the extended leads when you take a measure- ment. P7350 5 GHz Differential Probe Instruction Manual...
Extending the ground lead will have little, if any, affect on your measurements. In most circuits, the ground path from the differential source has sufficiently high impedance to damp out any ringing caused by lead inductance. P7350 5 GHz Differential Probe Instruction Manual...
Appendix A: Specifications The specifications in Tables 3 through 5 apply to a P7350 probe installed on a TDS6604 oscilloscope. The probe must have a warm-up period of at least 20 minutes and be in an environment that does not exceed the limits described in Table 3. Specifications for the P7350 differential probe fall into three categories: warranted, typical, and nominal characteristics.
Page 34
Rise time (probe only), 20--80% 250 mV step ±2.5 V Differential signal range ±1.25 V Differential offset range ±1% or less of dynamic range Linearity Common-mode signal range +6.25 V to --5.0 V P7350 5 GHz Differential Probe Instruction Manual...
Page 35
46 nV/√Hz @100 MHz ±2.0% DC Offset Scale Accuracy (gain of offset signal path) DC Offset Drift 150 V/°C or less at output of probe 0.94 mV/°C or less displayed on screen with TekConnect interface P7350 5 GHz Differential Probe Instruction Manual...
Page 38
6.25 X Input coupling Terminate output into 50 Ω Termination All TekConnect host instruments recognize this gain setting and adjust the Volts/Div setting to correspond to a normal 1- 2- 5 sequence of gains. P7350 5 GHz Differential Probe Instruction Manual...
TekConnect probe is connected to the adapter and identified by the oscilloscope. When a probe is detected through the adapter, the Volts/div readout on the oscilloscope displays ##. Refer to Table 8 on page 32 for detailed features of the calibration adapter. P7350 5 GHz Differential Probe Instruction Manual...
Page 44
Measure the offset voltage using a DVM, BNC Offset voltage coaxial cable and BNC-to-dual-banana jack. output Signal out. The SMA connector on the rear of the box allows for direct monitoring of the probe signal. Signal out P7350 5 GHz Differential Probe Instruction Manual...
The fixture is designed to be used with a probe positioner, such as a Tektronix PPM203B. Figure 19: Probe Calibration Fixture Using the Probe Calibration Fixture 1.
1. Connect the probe calibration adapter to the oscilloscope. 2. Connect the probe to the probe calibration adapter. 3. Turn on the oscilloscope and enable the channel. 4. Allow 30 minutes for the equipment to warm up. P7350 5 GHz Differential Probe Instruction Manual...
NOTE. Leave the offset switch in the ground position for all of the performance verification checks. 3. Set the multimeter to read DC volts. ± 4. Verify that the output voltage is 0 V, 10 mV. 5. Record the results on the test record. P7350 5 GHz Differential Probe Instruction Manual...
50 Ω Precision termination BNC-SMA adapter Calibration Power supply Power supply adapter P7350 Probe KlipChip adapters Black (- - ) Red (+) Y-lead adapter Square pin adapter Figure 22: DC Gain Accuracy setup P7350 5 GHz Differential Probe Instruction Manual...
Page 49
1. Connect the test equipment as shown in Figure 23 on page 38. CAUTION. Use care when working with SMA connectors: support equipment to avoid mechanical strain on the connectors, and use a torque wrench to tighten connections to 7 in-lbs. P7350 5 GHz Differential Probe Instruction Manual...
2. Set the CSA/TDS8000 oscilloscope trigger to internal clock. NOTE. The CSA/TDS8000 oscilloscope is used for taking the measurements in these procedures. All references to oscilloscope adjustments refer to the CSA/TDS8000. The TDS7404 oscilloscope is only used to power the probe. P7350 5 GHz Differential Probe Instruction Manual...
Page 51
11. Secure the probe head in the probe positioner. The test setup should now be connected as shown in Figure 24 on page 40. P7350 5 GHz Differential Probe Instruction Manual...
14. Using the probe positioner, probe the DM test points on the probe calibration fixture. Compare your display to Figure 25 on page 41 to verify that you have a valid connection with both pins. P7350 5 GHz Differential Probe Instruction Manual...
Record the rise time as t s+p. 18. Calculate the probe rise time using the following formula: − t (s+p) 19. Record the calculated probe rise time on the test record. P7350 5 GHz Differential Probe Instruction Manual...
Page 54
Date of Calibration: Technician: Performance test Minimum Incoming Outgoing Maximum -- 10 mV ________ ________ + 10 mV Output offset voltage DC gain accuracy 0.1568 ________ ________ 0.1632 Rise time ________ ________ 100 ps P7350 5 GHz Differential Probe Instruction Manual...
Appendix C: Maintenance This section details the maintenance for the P7350 differential probe. Inspection and Cleaning Protect the probe from adverse weather conditions. The probe is not waterproof. CAUTION. To prevent damage to the probe, do not expose it to sprays, liquids, or solvents.
Page 56
2. Put the probe into an antistatic bag or wrap to protect it from dampness. 3. Place the probe into the box and stabilize it with light packing material. 4. Seal the carton with shipping tape. P7350 5 GHz Differential Probe Instruction Manual...
Appendix D: Replaceable Parts This section contains a list of replaceable parts for the P7350 differential probe. Use this list to identify and order replacement parts. Parts Ordering Information Replacement parts are available from or through your local Tektronix, Inc. service center or representative.
Page 58
Indented items are part of, and included with, the next higher indentation. Attaching parts must be purchased separately, unless otherwise specified. Abbreviations Abbreviations conform to American National Standards Institute (ANSI) standard Y1.1 P7350 5 GHz Differential Probe Instruction Manual...
Need help?
Do you have a question about the P7350 and is the answer not in the manual?