VGE MultiMax Pro Installation & User Manual page 58

Uv-c sterilizer
Table of Contents

Advertisement

Problem
Water comes out of the irradiation
chamber.
Effect UV system is not good, not
enough reduction bound chlorine.
Effect UV system is not good, not
enough disinfection.
Indicator on control box flashes
green.
Indicator on control box lights up
red.
VGEM000-GB192
Pag. 58/68
Possible cause
Damaged or incorrectly positioned
O-ring that seals the quartz tube.
Damaged or broken quartz tube.
The UV transmission of the water
is too low.
The flow rate is too high.
Polluted quartz tube
UV lamp has too many operating
hours
UV lamp defective
Control panel defective
Incorrect sampling.
Possibly an overload of the bath.
The UV transmission of the water
is too low.
The flow rate is too high.
Polluted quartz tube
UV lamp has too many operating
hours
UV lamp defective
Control panel defective
Incorrect sampling.
Lamp almost needs to be replaced
(indicator flashes during the last
500 hours).
Lamp must be replaced
immediately, end of life is
reached.
VGE International B.V.
Ekkersrijt 4304
Installation & User Manual
Solution
Replace O-ring.
Replace quartz tube.
Improve the UV transmission of
the water or select another (more
powerful) UV system.
Reduce the flow or select another
(more powerful) UV system.
Clean or replace the quartz tube.
Replace UV lamp and reset Timer.
Replace UV lamp and reset Timer.
Replace control panel.
Ensure that the measuring
equipment is properly calibrated
and perform the measurement
again in accordance with the
applicable rules.
Wait until the UV system has done
its work, reduce the number of
visitors or select a more powerful
UV system.
Improve the UV transmission of
the water or select another (more
powerful) UV system.
Reduce the flow or select another
(more powerful) UV system.
Clean or replace the quartz tube.
Replace UV lamp and reset Timer.
Replace UV lamp and reset Timer.
Replace control panel.
Ensure that the sampling points
are properly disinfected before
taking the water samples and
repeat the measurement.
Make sure you have a spare lamp
on hand.
Replace UV lamp and reset Timer.