Handling Of Uv Lamps And Quartz Sleeves - VGE MultiMax Pro Installation & User Manual

Uv-c sterilizer
Table of Contents

Advertisement

On the control panel:
Voor het openen van de besturingskast de hoofdschakelaar uitschakelen!
Vor dem Öffnen des Steuerschrankes den Hauptschalter ausschalten!
Before opening the control panel switch off the main switch!
In the control panel:
Bij uitgeschakelde hoofdschakelaar kunnen er externe vreemde spanningen
aangesloten zijn!
Auch beim ausgeschaltetem Hauptschalter können extern angeschlossen
Fremdspannungen vorhanden sein!
Other external voltages may be present when the main switch is switched off!

2.5 Handling of UV lamps and quartz sleeves

The VGE Pro MP UV systems are equipped with medium pressure UV lamps and quartz tubes, the quartz
parts must be clean when they are put into operation.
If a UV lamp comes in contact with the skin, traces of grease remain on the lamp. When the UV lamp is
switched on, the traces of grease that remain behind block the light that wants to shine out of the lamp.
Because light is converted to heat, it will become very hot at the location of the grease (or other
contamination) and the lamp will burn out at this location.
To prevent the UV lamps and clean quartz tubes from being grabbed with bare hands, a set of white fabrics
and lint-free gloves are included with every delivery of a new UV system.
Grasp UV lamps only at the ceramic parts to prevent contamination of the quartz!
VGE International B.V.
Ekkersrijt 4304
Attentie!
Vorsicht!
Attention!
Attentie!
Vorsicht!
Attention!
Make sure that the safety instructions are always and remain legible and easy to
read!
The supplied gloves are intended to prevent UV lamps and quartz tubes from
remaining clean. These gloves offer no protection against cuts due to breakage of a
UV lamp or quartz tube.
5692 DH Son Netherlands
Installation & User Manual
 +31 499 461099
info@vgebv.nl
VGEM000-GB192
www.vgebv.nl
Pag. 19/68

Advertisement

Table of Contents
loading

This manual is also suitable for:

935mm0400

Table of Contents