Viessmann VITODENS 100-W Manual page 41

Table of Contents

Advertisement

Electrical connections
fÖ Mains power connection 230 V ~
50 Hz (green plug)
Do not interchange the supply
conductors L1 and the neutral
conductor N.
A two pole shut off switch with a
contact separation of at least
3 mm must be fitted in the mains
supply to the boiler with a maxi-
mum fuse value of 3 A.
A 1.5 m power cable is part of the
standard delivery.
Connect Vitotrol 100
A Vitotrol 100 UTD
Routing connecting cables
!
Achtung
Connecting cables can be damaged if they touch hot components.
When routing and securing connecting cables on site, ensure that the
maximum permissible cable temperatures are not exceeded.
(Fortsetzung)
gH Mains connection accessories/
room temperature control/DHW
cylinder control (black plug)
LR Connection of room temperature
control
Vitotrol 100 UTA
Vitotrol 100 UTD
B Vitotrol 100 UTA
Montageablauf
41