Viessmann VITODENS 100-W Operating Instructions Manual
Viessmann VITODENS 100-W Operating Instructions Manual

Viessmann VITODENS 100-W Operating Instructions Manual

Gas fired wall mounted condensing boiler with control unit for constant temperature operation
Hide thumbs Also See for VITODENS 100-W:

Advertisement

VIESMANN

Operating instructions

for the system user
Gas fired wall mounted condensing boiler
with control unit for constant temperature operation
VITODENS 100-W
Please keep safe.
5592 550 GB
2/2007

Advertisement

Table of Contents
loading

Summary of Contents for Viessmann VITODENS 100-W

  • Page 1: Operating Instructions

    VIESMANN Operating instructions for the system user Gas fired wall mounted condensing boiler with control unit for constant temperature operation VITODENS 100-W Please keep safe. 5592 550 GB 2/2007...
  • Page 2: For Your Safety

    Safety instructions For your safety Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions explained If you smell gas Danger Danger This symbol warns against the Escaping gas can lead to risk of injury. explosions which may result in serious injury.
  • Page 3 Safety instructions For your safety (cont.) In case of fire Ancillary components, spare and wearing parts Danger Fire creates the risk of burning Please note and explosions. Components which are not & Shut down the heating sys- tested with the heating system tem.
  • Page 4: Table Of Contents

    Index Index Introductory information Commissioning ................... Your system is preset at the factory ............. Certification details ..................General Description ..................Where to find the controls Summary of controls and indicators ............& Control and display elements ..............& Display indications................... Changing the room temperature ..............
  • Page 5: Introductory Information

    I2H (G20 with a gov- erned gas supply at 20 mbar (8 in.wg) inlet pressure). General Description The Vitodens 100-W is a fully auto- The unit provides central heating with matic, wall mounted, fan assisted output between 8.0 kW to 13.0/18.0 balanced flue condensing boiler for kW/240.0 kW.
  • Page 6: Where To Find The Controls

    Where to find the controls Summary of controls and indicators Control and display elements A tr Rotary selector "Heating B Fault display/reset button C Display water temperature" Display indications A Display value or fault code E Boiler primary water temperature B Circulation pump in operation in °C (combined with display C Burner in operation...
  • Page 7: Changing The Room Temperature

    Where to find the controls Changing the room temperature In addition to the boiler control unit, a separate room temperature controller must be installed in one of the living rooms to comply with part L of the building regulations if the heating system is to be regulated in accordance with the required room temperature.
  • Page 8: Start-Up/Shutdown

    Start-up/shutdown Starting the heating system The initial start-up must be carried out by your heating contractor. Before you switch ON a heating system that has been switched OFF for longer periods, it would be advisable to contact your CORGI registered gas installer. Switch ON the mains power.
  • Page 9: Settings

    Settings Heating If the room temperature controller Vitotrol 100, or similar programmable room thermostat is connected, then the room temperature is controlled from there. Observe the separate operating instructions. Should the room temperature controller not produce sufficient heat (e.g. when it's very cold), the heating temperature can be changed at the rotary selector "tr".
  • Page 10: Displays

    Displays Heating water temperature Checking the heating temperature During operation, heating water tem- perature is constantly displayed.
  • Page 11: Switching Off

    Switching OFF Switching OFF Vitodens with frost protection Switch OFF the equipment if you don't want to use the boiler for a few days. Turn rotary selector "tr" to "9". Boiler frost protection is active. Shutting down the heating system Shut down your heating system completely, if it will not be needed for longer periods of time (several months).
  • Page 12: What To Do If

    What to do if... System characteristics What to do if ... Cause Solution ... the heating system System switched off Switch on does not come on System controls includ- Switch on system con- ing room thermostats trols to create demand not calling for heat.
  • Page 13: Fault Display

    What to do if... System characteristics (cont.) What to do if ... Cause Solution … the burner switches Fault in air supply or in Contact your CORGI re- OFF although the desired the flue gistered heating engi- room temperature has neer.
  • Page 14: Maintenance

    Maintenance Cleaning The appliance casing can be cleaned using a damp cloth and a mild deter- gent. Do not use abrasive cleaners. Inspection and maintenance To ensure continued efficient opera- tion of the appliance, it is recom- mended that it is checked and serviced at regular intervals.
  • Page 15: Energy Saving Tips

    Energy saving tips Energy saving tips Apart from utilising the benefits of a modern heating systems, you can save additional energy by your own actions. The following measures will be helpful: & Correct airing. Open windows A briefly whilst closing all thermostatic valves B &...
  • Page 16: Keyword Index

    Your contact Contact your local contractor if you have any questions regarding the mainte- nance and repair of your system. You may, for example, find local contractors on the internet under www.viessmann.com. Viessmann Werke GmbH&Co KG Viessmann Limited D-35107 Allendorf...

Table of Contents