G. Appliance Break-In
Follow the initial break-in procedure below to cure the
materials used to manufacture the fireplace and the
finishing materials around it.
• The fireplace should be run three to four hours
continuously on high.
• Turn the fireplace off and allow it to cool completely.
• Remove fixed glass assembly. See Section 4.B.
• Clean fixed glass assembly. See Section 4.B.
• Replace the fixed glass assembly and run continuously
on high an additional 12 hours.
Note: The IntelliFire™ Touch system has a safety feature
that automatically shuts down the fireplace after 9 hours of
continuous operation without receiving a command from
the remote control. If this occurs, restart the appliance.
NOTICE! Open windows for air circulation during fire-
place break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
12
Majestic • MERID36IN, MERID36IL, MERID42IN, MERID42IL Owner's Manual • 2517-981 Rev. E • 1/19
H. Heat Management
Heat Output
This model has a variable burn rate which is controlled by
the command on the optional remote control, if installed.
The control module is located in the control cavity of the
appliance.
If an optional fan is installed, the fan speed is controlled by
adjusting the speed control knob or using the command
on the optional remote control, if installed. If the rheostat
included in the optional fan kit is installed, turn the knob
clockwise to increase the fan speed and counterclockwise
to decrease the fan speed.
If both the optional remote and optional fan are installed,
use the RC400 remote to set the fan speed or to turn the
fan OFF. The fan speed dynamic icon is used to change
the setting.

Advertisement

Table of Contents
loading

Table of Contents