Hearth & Home DV3732SBI Owner's Manual
Hide thumbs Also See for DV3732SBI:
Table of Contents

Advertisement

Models:
DV3732SBI
DV3732SBIL
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT GLASS WILL
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed.
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
CAUSE BURNS.
UNTIL COOLED.
1

Advertisement

Table of Contents
loading

Summary of Contents for Hearth & Home DV3732SBI

  • Page 1 Technologies suggests NFI certifi ed or factory trained appliance is not convertible for use with other professionals, or technicians supervised by an NFI gases, unless a certifi ed kit is used. certifi ed professional. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 2: Congratulations

    00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX XXXXXXXX XXXXXXXX (Serie): (Serie): Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 3: Table Of Contents

    F. Wall Switch Installation for Fan (Optional) ... . 52 6 Termination Locations A. Vent Termination Minimum Clearances ....20 Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 4 D. Contact Information ......77  = Contains updated information. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 5: Limited Lifetime Warranty

    Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645F 02-18-13 Page 1 of 2 Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 6 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645F 02-18-13 Page 2 of 2 Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 7: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 9: User Guide

    fi re or injury. DECORATIVE DOORS (NOT SHOWN) SECTION 2.D. FIXED GLASS ASSEMBLY (NOT SHOWN) SECTION 14G. MANTEL FAN KIT SECTION 2.C HEARTH Figure 2.1 General Operating Parts Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 10: Fan Kit (Optional)

    WARNING! Risk of Fire or Asphyxiation! DO NOT op- erate fi replace with fi xed glass assembly removed. Figure 2.2 Clear Space Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 11: Lighting Instructions (Ipi)

    See installation and operating instructions accompanying appliance. For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 12: After Fireplace Is Lit

    In an Intellifi re ignition system it is normal to see the pilot fl ame, but it should turn off when ON/ continually? OFF is turned off. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 13: Maintenance And Service

    • Carefully set fi xed glass assembly in place on fi replace. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 14: Maintenance Tasks-Qualifi Ed Service Technician

    • Remove all foreign objects. • Verify unobstructed air circulation. Burner Ignition and Operation Frequency: Annually Figure 3.1 IPI Pilot Flame Patterns Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 15: Installer Guide

    FRAMING/HEADER (SECTION 8.C) (SECTION 5.B) OPTIONAL WALL SWITCH MANTEL AND MANTEL LEG (SECTION 5.D, 13.B) SURROUND HEARTH EXTENSION GAS LINE (SECTION 11)  Figure 4.1 Typical System Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 16: Design And Installation Considerations

    Flat blade screwdriver 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300ºF minimum continuous exposure rating) One 1/4 in. female connection (for optional fan). Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 17: Framing And Clearances

    E Min. F Min. 59-1/2 62-1/4 16-1/4 48-1/2 68-3/4 15-1/16 7-1/2 7-1/8 DV3732SBI See Section 5.D for DV3732SBIL Alcove Installation 1067 1511 1117 1581 1232 1746 Figure 5.1 Appliance Locations Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 18: Constructing The Appliance Chase

    DV3732SBIL * Adjust framing dimensions for interior sheathing (such as sheetrock) C** Add 12 inches for rear venting with one 90º elbow. Figure 5.2 Clearances to Combustibles Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 19: Mantel And Wall Projections

    3-1/2 in. OR COMBUSTIBLE MATERIAL Figure 5.6 Wall Projection (Acceptable on one side of opening) 1/2 in. NON-COMBUSTIBLE ZONE Figure 5.4 Non-Combustible Zone Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 20: Termination Locations

    Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 21 2 sides beneath the fl oor. venting system does not meet these requirements. Figure 6.3 Minimum Clearances for Termination • Vinyl protection kits are suggested for use with vinyl siding. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 22: Vent Information And Diagrams

    Effective Height/Length DVP12 DVP24 DVP36 DVP48 1219 DVP6A 3 to 6 76 to 152 DVP12A 3 to 12 76 to 305 Figure 7.2 DVP Pipe Effective Length Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 23: Use Of Flex Vent

    However, 1 in. the vent attachment point and the fi restop CLEARANCE location are considered to be supports. Figure 7.3 Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 24: Vent Diagrams

    Note: There MUST be a 25% reduction in total H when using fl ex vent except when using the simple up and out installation (see Figure 7.3). Figure 7.4 Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 25 • When using DVP-TB1 termination cap on top vented fi replaces, a three foot minimum vertical vent section is required before installing fi rst elbow. Figure 7.5 Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 26 • When using SLP-HRC-SS and SLP-HRC-ZC- SS termination caps on top vented fi replaces, a one foot minimum vertical vent section is required before installing fi rst elbow. Figure 7.6 Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 27 fl ame height. If the vent confi guration has a total vertical of 15-60 feet, an exhaust restrictor may be needed. The exhaust restrictor can be located in the appliance manual bag. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 28 Note: There MUST be a 25% reduction HORIZONTALLY in total H when using fl ex vent except when using the simple up and out installation (see Figure 7.3). Figure 7.10 Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 29 Note: There MUST be a 25% reduction in total H when using fl ex vent except when using the simple up and out installation (see Figure 7.3). Figure 7.11 Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 30 = 24 in. Max. (610 mm) components only. Figure 7.12 Rear Vent - Horizontal Termination = 9 in. (229 mm) Maximum One 45º Elbow Note: Use DVP Series components only. Figure 7.13 Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 31 1.8 m 13-1/2 ft. 4.1 m HORIZONTALLY MAX. = 7-1/2 ft. (2.3 m) MAX. = 13-1/2 ft. (4.1 m) MAX. = 40 ft. (12.2 m) Figure 7.15 Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 32 2.0 m 3 ft. 914 mm H MAX. = 6-1/2 ft. (2 m) V + H+ H MAX. = 40 ft. (12.2 m) INSTALLED HORIZONTALLY Figure 7.17 Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 33 4.4 m MAX. = 7-1/2 ft. (2.3 m) MAX. = 14-1/2 ft. (4.4 m) MAX. = 40 ft. (12.2 m) Note: Use DVP Series components only. Figure 7.18 Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 34: Coaxial To Colinear Venting

    CAUTION! DO NOT use any fl ue restrictor when vent- ing with the DV-46DVA-GCL adapter and LINK-DV30B kit. This may result in poor fl ame appearance, sooting, pilot malfunction, or overheating. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 35: Rear Vent

    3.05 m 0 ft. 0 mm Minimum 10 ft. 3.05 m Maximum 40 ft. 12.2 m 2 ft. 610 mm Maximum 40 ft. 12.2 m Figure 7.21 Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 36: Vent Clearances And Framing

    * Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) in. (25.4 mm) above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 37: Install The Ceiling Firestop

    BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 38: Install Attic Insulation Shield

    • Bend all tabs inward 90º around the top of the shield. These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 39: Appliance Preparation

    2 SCREWS Figure 9.3 Replace the two screws as shown. Figure 9.6 Remove the insulation from the outer vent pipe. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 40: Rear Vent

    Use two self- tapping screws to secure gasket to outer wrap. Figure 9.9 Cut the metal retaining band and fold the sides out. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 41: Securing And Leveling The Appliance

    • Secure the appliance to the fl oor by inserting two screws through the pilot holes at the bottom of the appliance. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 42: Installing Vent Pipe (Dvp And Slp Pipe)

    fl ue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 10.4 Seams Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 43: Assemble Vent Sections (Slp Pipe Only)

    • Only outer pipes are sealed, sealing the inner fl ue is not required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 44: Secure The Vent Sections

    Figure 10.10 Rotate Seams for Disassembly connection point to appliance. Figure 10.11 Align and Disassemble Vent Sections Figure 10.8 Securing Vertical Pipe Sections Figure 10.9 Securing Horizontal Pipe Sections Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 45: Install Decorative Ceiling Components (Slp Only)

    fl aps and the roof. Figure 10.13 WARNING! Risk of Fire! Clean out ALL materials from inside the support box and complete the vertical vent run and termination. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 46: Install Metal Roof Flashing

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 10.15. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 47: Install Vertical Termination Cap

    • Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 10.18. Figure 10.18 Wall Thimble Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 48: Install Horizontal Termination Cap (Dvp And Slp Pipe)

    DVP-TRAP1 can adjust 1-1/2 in. (3-1/8 to 4-5/8) DVP-TRAP2 can adjust 4 in. (5-3/8 to 9-3/8) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 49: Gas Information

    • If substituting for these components, please consult Check with your local gas utility to determine proper local codes for compliance. orifi ce size. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 50: Electrical Information

    Remove batteries before using the transformer, and unplug the transformer before installing the batteries. Battery polarity must be correct or module damage will occur. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 51 3 VAC WHITE GROUND TO FIREPLACE PLUG IN CHASSIS WIRES BATTERY PACK (TO BROWN) REMOTE PLUG IN VALVE Figure 12.2 Intellifi re Ignition Wiring Diagram with Remote Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 52: Junction Box Installation

    Figure 12.4 Junction Box Wired to Wall Switch or BC10 (1/4 in. male) as shown. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 53: Finishing

    Figure 13.2 Step 3. Crease fl aps on left and right sides of splatter guard Figure 13.5 using the scored line as the guide. See Figure 13.3. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 54 Carefully grab splatter guard on or near the vertical center on the left and right sides. Pull outward gently, but fi rmly, Figure 13.8 taking care not to tear or remove the inserted tabs. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 55: Mantel And Wall Projections

    Note: Clearance from opening to perpendicular wall. Figure 13.13 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) NON-COMBUSTIBLE ZONE Figure 13.15 Non-Combustible Zone Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 56: Facing Material

    MAY BE COMBUSTIBLE - TOP AND SIDES 0 IN. 0 IN. 0 IN. HIGH TEMPERATURE SEALANT (300° F/149° C MIN.) TOP AND SIDE SEAL JOINT Figure 13.16 Noncombustible Facing Diagram Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 57: Doors

    (Includes 1/8 in. opening each side of door) Finishing material between 1 and 4 inches thick. Refer to Table 1 for X and Y dimensions. Figure 13.20 Operable Hinge Door (Halston) Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 58: Elevated Hearth Systems

    Note 1. Add dimensions to Wall Penetration (Figure 8.2) and Rough Opening Height (Figure 5.2). Note 2. Verify Marble Cut Lengths on site prior to cutting. Note 3. Dimensions assume use of a 3/4 in. Hearth Pad. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 59: Appliance Setup

    PORT HOLES IN CIRCLED AREA SHOULD BE COVERED WITH EMBER MATERIAL. NO OTHER PORT HOLES MAY COME INTO CONTACT WITH EMBER MATERIAL. Figure 14.4 Placement of Embers Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 60: Install The Log Assembly

    B as shown in Figure 5. When properly positioned, Log #1 will touch Tab B and sit on Log Rest. See Figure 4 to reference the position of Tab B and the log rest . Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 61 • Do NOT place lava rock on burner top. operation. • Use ONLY Hearth & Home Technologies-approved Delayed ignition may occur. optional media with this appliance. 2158-935C Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 62: Fixed Glass Assembly

    • Use non-combustible materials to cover the gap between Models the sheet rock and the appliance (when applicable to DV3732SBI 1/8 in. 1/2 in. model). DV3732SBIL Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 63: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. D. Module voltage output / Valve/Pilot Verify battery voltage is at least 2.7 volts. Replace batteries if volt- solenoid ohms readings. age is below 2.7. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 64 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fi ne. Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 65: Reference Materials

    GAS LINE ACCESS ELECTRICAL ACCESS Location Inches Millimeters Location Inches Millimeters 16-3/8 27-3/16 25-3/4 12-7/8 15-7/8 3-1/2 6-5/8 6-7/8 34-3/8 2-3/16 36-1/2 8-3/4  Figure 16.1 Appliance Dimensions Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 66: Vent Components Diagrams

    14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.2 DVP vent components Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 67 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC1 DVP-HPC2 Figure 16.3 DVP vent components Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 68 13-7/8 in. 9-1/2 in. 26 in. (352 mm) (241 mm) 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Figure 16.4 DVP vent components Cap Shield Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 69 1 in. (25 mm) (222 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) 1-5/8 in. (41 mm) DVP-FBHT FireBrickTermination Cap DVP-HPC High Performance Cap Figure 16.5 DVP vent components Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 70 (381 mm) 267 mm 10-7/8 in. 276 mm SLP-HRC-SS SLP-HRC-ZC-SS HORIZONTAL TERMINATION CAP DVP-TB1 DVP-TB1 SL-2DVP SLP90 ASSEMBLY DVP-TB1 HORIZONTAL TERMINATION CAP Figure 16.7 SLP Series Vent Components Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 71 1-1/2 in. 5-1/2 in. 12 in. 220 mm 38 mm 305 mm 146 mm SLP-WS SLP-FS Wall Shield Firestop Ceiling Firestop Figure 16.8 SLP Series Vent Components Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 72 367 mm 26 in. 660 mm 2-5/16 in. 14-7/16 in. 59 mm 367 mm DVP-HSM-B SLP-WT-BK Extended Heat Shield Wall Thimble-Black Figure 16.9 SLP Series Vent Components Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 73 1 in. (25 mm) 13-1/2 in. 343 mm 7-3/4 to 10-3/8 in. (197 to 264 mm) DVP-FBHT SLK-SNKD Horizontal Snorkel Termination Cap Termination Cap Figure 16.10 SLP Series Vent Components Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 74 (318 mm) SLP Low Profi le Cap COAXIAL to COLINEAR VENTING LINK-DV30B DVP-2SL DV-46DVA-GCL Flex Liner Kit Adapter Coaxial/Colinear Appliance Connector Figure 16.11 Coaxial to Colinear Vent Components Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...
  • Page 75: Service Parts List

    5890485, 5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945B Printed in U.S.A. - Copyright 2013 Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. i • 8/13...

This manual is also suitable for:

Dv3732sbil

Table of Contents