Selecting the operating mode
Saturday and Sunday
Time phase
Start
1
07:00
2
08:00
3
12:00
4
14:00
5
18:00
6
23:00
Frost protection mode
If you do not want to heat the interior but
would like to have frost protection.
Central heating starts if the room tem-
perature falls below 5 °C.
Note
DHW heating is OFF.
1. Open the flap.
"Manual" (operation with constant room temperature)
Central heating operates continuously
with the selected temperature.
1. Open the flap.
2. Press
twice.
3. Select "Manual" with / .
4. Confirm twice with OK.
Note
At this point, you can also start or stop
DHW heating during this operating
mode (see chapter "DHW heating").
(cont.)
End
Room temperature
08:00
Comfort
12:00
Comfort
14:00
Comfort
18:00
Comfort
23:00
Comfort
07:00
Reduced
2. Press
3. Select "Frost pr." with / .
4. Confirm with OK.
The display shows
room temperature.
5. Set the required room temperature
with / (at least 10 °C).
6. Confirm with OK.
The display shows
room temperature.
Central heating
twice.
and the current
and the current