Preparing For Installation; Installation Location For Weather-Compensated Mode; Installation Location For Room Temperature-Dependent Mode; Specifications - Viessmann VITOTROL 100 OT Installation & Service Instructions Manual

Opentherm room temperature controller with digital time switch for vitodens 100-w & vitodens 111-w
Table of Contents

Advertisement

Preparing for Installation

Installation Location for Weather-Compensated Mode

The device can be installed anywhere in the room.

Installation Location for Room Temperature-Dependent Mode

On an internal wall in the main living room, approx. 1.5m above the floor
Not next to windows or doors
Not above radiators
Not between shelves, in tight spaces etc.
Not near heat sources (direct isolation, fireplace, TV, etc.)
Note: Do not install further control devices in the main living room. If the radiators are equipped with
thermostatic valves, these must always be fully open.

Specifications

Power Supply
IP Rating
Protection Class
Power Reserve
Accuracy
Via OpenTherm
IP 20 to EN 60529
II to EN 60730-1 subject to correct installation
4 hours
≤ 1 s/day at 20˚C