Viessmann Vitovalor 300-P Installation And Service Instructions For Contractors page 104

Micro chp unit based on a fuel cell with integral gas condensing boiler natural gas version
Hide thumbs Also See for Vitovalor 300-P:
Table of Contents

Advertisement

Codes
Coding level 2
(cont.)
Coding
Coding in the delivered condition
56:0
Set DHW temperature adjustable
from 50 to 60 °C
57:0
Never adjust
58:0
Without auxiliary function for DHW
heating
59:0
Cylinder heating:
Start point -2.5 K
Stop point +2.5 K
5A:1
Never adjust
5E:0
Never adjust
5F:0
Never adjust
60:20
During DHW heating, the boiler
water temperature is set up to 20 K
higher than the set DHW tempera-
ture.
62:2
Circulation pump with 2 min run-on
time after cylinder heating
65:...
Never adjust
Information on type of diverter
valve, defaulted by the coding card
6C:100
Set speed of internal circulation
pump for DHW heating 100 %
6F:...
Max. heating output for DHW heat-
ing in %, defaulted by the coding
card
71:0
DHW circulation pump: "ON" ac-
cording to time program
72:0
DHW circulation pump: "ON" ac-
cording to time program
73:0
DHW circulation pump: "ON" ac-
cording to time program
104
Possible change
56:1
Set DHW temperature adjustable
from 50 to 60 °C
Note
Maximum value subject to boiler
coding card.
Observe the maximum permissible
DHW temperature.
58:50
Input of a second set DHW tempera-
to
ture, adjustable from 50 to 60 °C.
58:60
Observe coding address "56" and
"63" in this group.
59:1
Start point adjustable from 1 to 10 K
to
below set value
59:10
60:5
The differential between the boiler
to
water temperature and the set DHW
60:25
temperature is adjustable from 5 to
25 K
62:0
No circulation pump run-on
62:1
Run-on time adjustable from 1 to
to
15 min
62:15
6C:0
Set speed adjustable from 0 to
to
100 %
6C:100
6F:0
Max. heating output for DHW heat-
to
ing adjustable from min. heating out-
6F:100
put to 100 %
71:1
"OFF" during DHW heating to set
value 1
71:2
"ON" during DHW heating to set val-
ue 1
72:1
"OFF" during DHW heating to set
value 2
72:2
"ON" during DHW heating to set val-
ue 2
73:1
During time program
to
"ON" for 5 min once an hour up to
73:6
"ON" for 5 min six times an hour
73:7
Permanently "ON"