Kenmore W11024188A Installation Instructions Manual page 5

Table of Contents

Advertisement

Available languages

Available languages

Mobile Home - Additional Installation Requirements
The installation of this range must conform to the
Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280 (formerly the Federal Standard for
Mobile Home Construction and Safety, Title 24, HUD Part
280). When such standard is not applicable, use the Standard
for Manufactured Home Installations, ANSI A225.1/NFPA 501A
or local codes.
In Canada, the installation of this range must conform with
the current standards CAN/CSA - A240-latest edition or with
local codes.
Mobile Home Installations Require:
When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the
standards listed above.
Product Dimensions
This manual covers several models. Your model may appear
different from the models depicted. Dimensions given are
maximum dimensions across all models.
A
C
D
E
F
A. 1
/
" (3.0 cm) height from
3
16
cooktop to top of vent
B. 29
7
/
" (75.9 cm)
8
C. Model/serial/rating plate
(located behind the oven
door on the top left-hand
side of the oven frame)
IMPORTANT: Range must be level after installation. Follow the
instructions in the "Level Range" section. Using the cooktop as
a reference for leveling the range is not recommended.
* Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
B
D. 36" (91.4 cm) height to
top of cooktop edge with
leveling legs screwed in all
the way*
E. 28
25
/
" (72.1 cm) max.
64
depth from front of console
to back of range
F. 29
1
/
" (73.7 cm) max.
64
depth from handle to back
of range
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm)
countertop depth, 24" (61.0 cm) base cabinet depth, and
36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.
Range may be installed next to combustible walls with zero
clearance.
A. 18" (45.7 cm) upper side cabinet to countertop
B. 13" (33 cm) max. upper cabinet depth
C. 30" (76.2 cm) min. opening width
D. For minimum clearance to top of cooktop, see NOTE.
E. 30" (76.2 cm) min. opening width
F. 3" (7.6 cm) min. clearance from both sides of range to side wall
or other combustible material
G. The shaded area is recommended for installation of rigid gas pipe
and grounded outlet.
H. 13
/
" (33.3 cm)
1
8
I. 7
/
" (19.5 cm)
11
16
J. 4
13
/
" (12.2 cm)
16
K. 3
11
/
" (9.4 cm)
16
L. 12" (30.5 cm)
M. Cabinet door or hinges should not extend into the cutout.
NOTE: 24" (61.0 cm) minimum when bottom of wood or
metal cabinet is shielded by not less than 1/4" (0.64 cm)
flame-retardant millboard covered with not less than No. 28
MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024"
(0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the
cooking platform and the bottom of an uncovered wood
or metal cabinet.
5

Advertisement

Table of Contents
loading