Type in the gateway's MAC and local IP address to the fields Router MAC and
Router Ip.
Press Start Scan.
Debug Tool now starts to list all Bluetooth devices within its range. For all scanned
devices the tool is showing the MAC address and RSSI value. Sometimes the name
is not available, but it is listed if known. All ABB Smart Sensor MACs start with
50:31:AD.
RSSI value can be roughly categorized to the following groups:
If the desired Smart Sensors are showing RSSI values of around -70, it is
recommended to adjust the gateway's location or orientation.
!
NOTE! Remember to change the router mode back to AC Managed Router. If the mode is
not changed, the gateway is will not be able to establish a connection to the AC server and
the data will not be read from the Smart Sensors.
!
NOTE! If the gateway's container is displaying the error status, resetting the gateway will
NOT solve this error. To check this please go into the gateway settings page under the
Container tab. In case this happens, please contact Smart Sensor support.
For more support, please contact Smart Sensor support:
support.smartsensor@abb.com
DOCUMENT ID
9AKK107046A4620
© Copyright 2021 ABB. All rights reserved.
Figure 18 Cassia Bluetooth Debug Tool
RSSI value between 0 and -70 is OK
-
RSSI value between -70 and -80 is weak, sensor might be read from time
-
to time
RSSI value -80 or less is poor, most probably the sensor cannot be read
-
REV.
K
AB B ABI LIT Y™ SM ART S ENSO R BLU ETOOTH ® G AT EWAY