ABB Ability Cassia X2000 Installation Manual

ABB Ability Cassia X2000 Installation Manual

Smart sensor bluetooth gateway

Advertisement

Quick Links

AB B M OT I O N S ER V I CE S
ABB Ability™ Smart Sensor Bluetooth
Gateway
Cassia X2000 installation manual
DOCUMENT ID
4MWA000032
© Copyright 2023 ABB. All rights reserved.
REV.
B
DATE
February 2023
®
LANG.
PAGE
EN
1/29

Advertisement

Table of Contents
loading

Summary of Contents for ABB Ability Cassia X2000

  • Page 1 AB B M OT I O N S ER V I CE S ® ABB Ability™ Smart Sensor Bluetooth Gateway Cassia X2000 installation manual DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 1/29 © Copyright 2023 ABB. All rights reserved.
  • Page 2: Table Of Contents

    USB mobile dongle connection ................... 16 Firewall configuration ....................19 Verifying the configuration ..................20 2.10 Commissioning the gateway ................... 23 3 TROUBLESHOOTING ................. 25 DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 2/29 © Copyright 2023 ABB. All rights reserved.
  • Page 3: General

    AB B ABI LIT Y™ SM ART S ENSO R BLU ETOOTH ® G AT EWAY General The ABB Ability™ Smart Sensor gateway is used to upload the Smart Sensor data automatically to the Smart Sensor portal. The gateway needs to be configured for Internet access before it can start reading the Smart Sensors.
  • Page 4: Installation

    Only one AC address must be whitelisted in the network. For gateways working outside China, the Global AC address must be whitelisted. For gateways working inside China, only the China AC address must be whitelisted. DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 4/29 © Copyright 2023 ABB. All rights reserved.
  • Page 5 Phillips head screwdriver and a drill (if needed) for wall mounting. Mounting is not mandatory, but it is recommended to secure the gateway to its intended place. DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 5/29 © Copyright 2023 ABB. All rights reserved.
  • Page 6: Recommended Location

    If the gateway has trouble connecting to a specific Smart Sensor, it is recommended to rotate the gateway to point in that direction. DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 6/29 © Copyright 2023 ABB. All rights reserved.
  • Page 7: Gateway Configuration

    AC server. Access Controller server connection is needed for a successful Smart Sensor data transfer. DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 7/29 © Copyright 2023 ABB. All rights reserved.
  • Page 8 China AC Address: gw.smartsensor.abb.com.cn AC-Router Protocol Priority: MQTT see description below Connection Priority: Enable OAuth2 Token For Local API: OFF Remote Assistance: ON DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 8/29 © Copyright 2023 ABB. All rights reserved.
  • Page 9 2.9 Verify- ing the configuration to check if the connection has been successfully set-up. DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 9/29 © Copyright 2023 ABB. All rights reserved.
  • Page 10 AB B ABI LIT Y™ SM ART S ENSO R BLU ETOOTH ® G AT EWAY Figure 4 Basic page configuration for Cellular/4G connection DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 10/29 © Copyright 2023 ABB. All rights reserved.
  • Page 11 If left on Auto mode the gateway could end up not properly connecting to the internet, needing to be power cycled to restore connection. Figure 5 4G only network mode DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 11/29 © Copyright 2023 ABB. All rights reserved.
  • Page 12: Poe Connection

    Connection Priority: Wired IP Allocation: DHCP or Static (in case the IP address is given) Press Apply at the bottom of the screen. DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 12/29 © Copyright 2023 ABB. All rights reserved.
  • Page 13: Lan/Ethernet Cable Connection

    Connection Priority: Wired IP Allocation: DHCP or Static (in case the IP address is given) Press Apply at the bottom of the screen. DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 13/29 © Copyright 2023 ABB. All rights reserved.
  • Page 14: Wifi Connection

    Enter the WIFI network password Change the Wireless operation mode from Hotspot to Client IP Allocation: DHCP or Static (in case the IP allocation is given) DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 14/29 © Copyright 2023 ABB. All rights reserved.
  • Page 15 Press the reset button at the bottom of the gateway for 10 seconds to reset the gateway to factory default values, while the gateway is connected to power. DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 15/29 © Copyright 2023 ABB. All rights reserved.
  • Page 16: Usb Mobile Dongle Connection

    Or alternatively, a 12V – 2A adapter (see 2.1 Prerequisites for installation on page 5). Figure 11 Mobile network configuration for PoE Figure 12 Mobile network configuration for 12V adapter DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 16/29 © Copyright 2023 ABB. All rights reserved.
  • Page 17 However, the Cassia X2000 supports other dongle types, the list of which can be found in the local configuration, at the bottom of the Basic tab, under Cellular Modem, USB Modem Type. DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 17/29 © Copyright 2023 ABB. All rights reserved.
  • Page 18 (e.g. check if Huawei can be used in the US) DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 18/29 © Copyright 2023 ABB. All rights reserved.
  • Page 19: Firewall Configuration

    Firewall should allow communication between the gateway and Access Controller, and gateway and Smart Sensor platform respectively (see required ports in section 2.1 Prerequisites for Installation). DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 19/29 © Copyright 2023 ABB. All rights reserved.
  • Page 20: Verifying The Configuration

    If the AC Online Time is not shown within few minutes: Double check the configuration and Internet connection Reboot the gateway (power off/on) DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 20/29 © Copyright 2023 ABB. All rights reserved.
  • Page 21 Connection to Access Controller can be verified with Debug Tools in Other tab: To check the connection to the Access Controller, select NetCat, add Address gw.smartsensor.abb.com (or gw.smartsensor.abb.com.cn in case of China), Pro- tocol TCP, Timeout 2, Port 8883 and press Start.
  • Page 22 Connection to Smart Sensor Portal can be verified as well with Debug Tools in Other tab: To verify TCP port open/close status select NetCat, add Address smartsen- sor.abb.com (or smartsensor.abb.com.cn in case of China), Protocol TCP, Timeout 2, Port 443 and press Start. Wait for the black screen with the result to appear below.
  • Page 23: Commissioning The Gateway

    Read the popup message, and make sure the gateway is in the required range. Tap OK, to confirm. Figure 20 Mobile APP Commission gateway option DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 23/29 © Copyright 2023 ABB. All rights reserved.
  • Page 24 Figure 21 Select gateway for commissioning Finally, select a plant where you want to commission the gateway. • Figure 22 Assign gateway to a plant DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 24/29 © Copyright 2023 ABB. All rights reserved.
  • Page 25: Troubleshooting

    Check if the Router Web Security under Other tab is toggled OFF (see below). Figure 23 Router web security option DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 25/29 © Copyright 2023 ABB. All rights reserved.
  • Page 26 The fields must be completed as shown below, then click Start. It will take ~10 seconds for the result to be shown. Figure 24 SpeedTest tool DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 26/29 © Copyright 2023 ABB. All rights reserved.
  • Page 27 The fields must be completed as shown below, then click Start. It will take ~10 seconds for the result to be shown. Figure 25 Traceroute tool DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 27/29 © Copyright 2023 ABB. All rights reserved.
  • Page 28 Bluetooth of the phone is active and wait for the list to populate. The APP shows both the signal quality and commissioning status. DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 28/29 © Copyright 2023 ABB. All rights reserved.
  • Page 29 Container tab. In case this happens, please contact Smart Sensor support. For more support, please contact Smart Sensor support: support.smartsensor@abb.com DOCUMENT ID REV. DATE LANG. PAGE 4MWA000032 February 2023 29/29 © Copyright 2023 ABB. All rights reserved.

Table of Contents