Figure 6-6 – Smart Sensor Module (80-8000-00A0-10)

6.4.1 Sensor Separation Kit

Smart Sensor Modules may be remote mounted up to 15 feet using the Sensor Separation Kit connected to TB1 or
TB2 of the Battery Board (see Figure 3 2). The Sensor Separation Kit comes with 15 feet of data cable and assures
proper communication over the Smart Sensor Interface.
NOTE: Alternate cable types and longer distances are not approved and may result in poor performance.
Figure 6-7 – Sensor Separation Kit
REV – 1.3
[34-2900-0207-4 ]