Test the Oscillate Axle - GS-90

Genie specifications require that this procedure be
performed annually.
The oscillate system is designed so that all four
tires maintain firm contact to the ground on unlevel
terrain improving traction and machine stability.
Proper axle oscillation is essential to safe machine
operation. If the axle oscillation system is not
operating correctly, the stability of the machine is
compromised and it may tip over.
Note: Perform this procedure on a firm, level
surface with the platform in the stowed position in
a safe, secure location away from obstacles and
with an area working height of 20 ft / 6 m.
Note: The outrigger, if equipped, must be fully
retracted.
1
Disconnect and remove the platform controller
from the platform.
2
Open the ground control panel door and
locate the cable connector below the ground
controls. Unplug the control cable from the
ground control plug and connect the platform
controller to the cable.
3
Remove the two retaining fasteners from the
ground control panel and set aside. Tilt the
control panel out towards you exposing the
wiring and relays.
Part No. 1305686GT
Annual Maintenance Procedures
Test relay K11
Note: Perform this test using the platform controls
while standing on the ground as described below.
4
At the ground controls, turn the key switch to
platform controls and pull out the red
Emergency Stop button.
5
Pull out the red Emergency Stop button on
the platform controller and start the engine.
6
Using a volt meter, check for voltage by
connecting the positive lead to relay K11,
terminal 30 and connecting the negative lead
to the ground strip terminal.
Result: The volt meter should read 12V DC or
greater.
Result: The volt meter reads 0V DC.