5.5

Saving customer-specific speed rates

i
The RPM can be programmed from 100 to 4000 with
resolution of 1 RPM.
1. Press <RPM selection> for three seconds till the cur-
sor blinks on the HMI display.
 The program number and the corresponding RPM
value are displayed.
2. Press <o> or <u> to select any program number from
41 to 99.
i
Any program from 41 to 99 can be used for defining
"custom" preset speeds.
3. Press <Enter>.
4. Using the numerical keys, enter an RPM value
5. Press <Enter>.
"
The required RPM value is stored.
5.6

Activate stroke counting

!
Do not actuate <Stroke counter On/Off> on the dis-
play and control unit at standstill of motor.
i
Stroke actuation can be done only if the actual RPM
does not vary by more than ± 5 RPM with respect to
set RPM.
Press <Stroke Counter On/Off>.
"
The stroke counter starts the measurement and counts
the strokes down. The test oil starts accumulating in
the measuring glass tubes. Once the number of strokes
reaches 0, the measurement stops.
i
To stop the stroke counter before completion of
preset strokes, press <Stroke Counter On/Off>.
The value at which the stroke counter is stopped is
displayed
|
F 002 DG9 918
2017-10-16
6.

Operation

Wear safety goggles.
Wear safety gloves.
Wear slip resistant safety shoes.
Wear ear mufflers.
Wear a safety mask.
Warning - Risk of injury due to spillage
of test oil or due to parts being thrown
around!
If the high pressure lines are not connected
to the fuel injection pump correctly, test oil
can spurt out at high pressure, or parts of
the fuel injection pump under test can fly
apart during the test.
Do not operate the EPS 610 without
mounting the fuel injection pump.
Before switching on, check if all the high
pressure lines are connected properly.
Do not open the
EPS 610 drive has stopped.
Replace any leaking and defective hose
lines.
Wear safety goggles.
Wear slip-resistant safety shoes.
Warning: Noise can impair hearing
When performing tests with the EPS 610,
the noise level is in excess of 80 dB(A). Such
noise levels can permanently impair hearing.
Wear ear mufflers.
6.1

Switch-on

1. Close the shut-off cock for the test oil
2. Switch on the EPS 610 at the master switch.
 The EPS 610 is ready for operation.
3. Press the <Heater on /off> key to start heating the
test oil.
4. From the HMI, switch on the test oil pump
coupling
guard, until the
supply.
Bosch Limited