7. Event Commands
Command
get events
get time
set time server < dotted decimal >
set time enable < yes | no >
set event <1-8> <run | hold>
set event < 1-8 > date < mm/dd/yyyy >
set event < 1-8 > time < hh:mm:ss >
set event < 1-8 > repeat < day | hour |
minute >
set event < 1-8 > mult < 0-999 >
set event < 1-8 > action < on | off | cycle >
del event < 1-8 >
© AMETEK Electronic Systems Protection, Inc. | Technical Support: 800-645-9721 | surgex.com
SA-82-AR
Description
Returns all scheduled events currently in use. Example:
Date
Time Repeats
Action
1. 12/22/2011 14:00 every 2 Hour(s) Cycle
2.
every 0 Day(s) On
3.
every 0 Day(s) On
4.
every 0 Day(s) On
5.
every 0 Day(s) On
6.
every 0 Day(s) On
7.
every 0 Day(s) On
8.
every 0 Day(s) On
Returns the current time and time server. Example:
Current Time: 10:14:17 12/20/2011
Server:
10.1.2.12
Sets the IP address of a Network Time Server.
Enables or disables the use of a time server and scheduled events.
Allow the event to run, or put the event on hold.
Sets the scheduled event's starting date.
Sets the time the scheduled event will occur in 24-hour format.
Sets the repetition interval type for the selected event.
Sets the number of repetition intervals for the selected event. For example,
20 days, 30 minutes, 24 hours, etc.
Sets the action to be performed at the scheduled time.