Check the indicator lamps and respond as indicated below.
Indicator lamp
Odour sensor lamp is
blinking.
Streamer sensor lamp is
blinking.
All 3 MODE lamps are
blinking simultaneously.
All 4 FAN lamps are
blinking simultaneously.
17
This lamp blinks if the deodorising filter unit has become detached or is not attached properly.
 Attach the deodorising fi lter unit properly.
It is time to replace the streamer unit.
An electrical component is faulty.
 Contact the place of purchase.
Are the pre-fi lter, outfl ow grille,
and dust collection fi lter attached?
These lamps may blink if the unit
is operated without a part
attached.
Is there a buildup of dust on the
pre-filter?
Is the air outlet blocked?
These lamps may blink if there is a sudden drop in voltage.
Cause/Solution
►Page 14
►Page 15
„ If all parts are attached
An electrical component is faulty.
 Contact the place of purchase.
„ If one or more components are not attached
Remove the power supply plug, reattach the parts
and then turn the unit on again.
„ If there is no dust buildup
An electrical component is faulty.
 Contact the place of purchase.
„ If there is a dust buildup
Remove the power supply plug, clean the pre-fi lter
and then turn the unit on again.
„ If the air outlet is not blocked
An electrical component is faulty.
 Contact the place of purchase.
„ If the air outlet is blocked
Remove any obstacles blocking the air outlet and
then turn the unit on again.