Advertisement

Quick Links

Air purifier
Floor standing or desktop type
Floor standing or desktop type
Model
MC40UVM6
• Thank you for purchasing this air purifier.
• Please read the operation manual carefully and follow it for correct use.
• Please read the "Safety Precautions" section before use.
Please keep the operation manual in a safe place for later reference.
Air Purifier
OPERATION MANUAL
►Page 3, 4

Advertisement

Table of Contents
loading

Summary of Contents for Daikin STREMER MC40UVM6

  • Page 1 Air purifier Floor standing or desktop type Floor standing or desktop type Air Purifier Model MC40UVM6 OPERATION MANUAL • Thank you for purchasing this air purifier. • Please read the operation manual carefully and follow it for correct use. • Please read the “Safety Precautions” section before use. ►Page 3, 4 Please keep the operation manual in a safe place for later reference.
  • Page 2: Read First

    Read First Features Streamer Technology Streamer discharge decomposes adsorbed odour. • Decomposition cycle that maintains deodorising capacity. Adsorption Odour Deodorising catalyst Deodorising catalyst adsorbs odour. Replacement of the deodorising This cycle catalyst is maintains This technology employs a “streamer discharge”, a unnecessary.
  • Page 3: Table Of Contents

    Read First Contents Read First Features ................Safety Precautions ............Names of Parts and Operations ........Preparation Before Operation .......... Using the Air Purifying Operation ........Operation Changing the Airfl ow Rate ..........Operating the Unit in a MODE ........10 Useful Functions AUTO FAN / ECONO / ANTI-POLLEN Adjusting Indicator Lamp Brightness ........
  • Page 4: Safety Precautions

    Read First Safety Precautions „ Observe these precautions in order to prevent property damage or injury. „ The consequences of incorrect use are categorised as follows. WARNING CAUTION Failure to follow these instructions properly may Failure to follow these instructions properly result in property damage or personal injury, which may result in personal injury or loss of life.
  • Page 5 Read First WARNING Observe in order to prevent fires, electric shocks or severe injury. „ Immediately turn off and unplug the unit if there are any signs of abnormality or damage Examples of abnormality or damage • The unit does not operate even if the switch is turned on. •...
  • Page 6: Names Of Parts And Operations

    Read First Names of Parts and Operations CAUTION Do not lift up the unit holding the grip on the deodorising filter unit. (May lead to falling over) Front Back Operating/Indicator panel Air outlet ►Page 6, 7 Grip (for carrying the unit) Deodorising filter unit Model name /...
  • Page 7 Read First Operating/Indicator panel When a lamp is blinking ►Page 17 MODE lamps [green] ON/OFF lamp [green] Indicate the MODE in operation. Lamp will light up when the power is ON. FAN lamps [green] Streamer lamp [blue] Indicates the active FAN setting (4 settings: Quiet, Low, Standard, Lights up when the streamer is active Turbo).
  • Page 8: Preparation Before Operation

    Read First Names of Parts and Operations Operating/Indicator panel FAN/MODE button ON/OFF button Press to cycle between FAN settings Press to turn the power ON or OFF. ►Page 9 ►Page 9-11 and MODEs. Accessories Operation manual ..1 Preparation Before Operation Positioning the unit Pointers for good positioning Before installation, peel off the...
  • Page 9 Read First Preparation Before Operation Do not use in the following places „ Places exposed to direct sunlight „ Do not use cosmetics etc., containing silicone* near the unit. (Discolouration may result) * Hair care products (split ends coating agents, hair „...
  • Page 10: Operation

    Operation WARNING Operation Do not turn off the unit by unplugging it from the power socket. (Fire or an electric shock may result from heating) Using the Air Purifying Operation (turning operation ON/OFF) Cleans the air in the room. Press •...
  • Page 11: Operating The Unit In A Mode

    Useful Functions Useful Functions Operating the Unit in a MODE Select a MODE specifi c to your needs. Airfl ow is adjusted automatically when the unit is running in a MODE. Press • Each press cycles between the MODE lamps [green] and FAN lamps [green]. MODE (AUTO FAN) (ECONO)
  • Page 12: Adjusting Indicator Lamp Brightness

    Useful Functions Useful Functions Adjusting Indicator Lamp Brightness Indicator lamp brightness is adjustable. Press for 3 seconds. • Press to cycle between settings. BRIGHT • The FAN setting and MODE of operation will also switch. After switching to the desired brightness, press and select FAN setting and MODE of operation again.
  • Page 13: Advanced Settings

    Advanced Settings Advanced Settings When the sensitivity of the dust/PM2.5 sensor does not meet your preferences *Setting at time of purchase Setting Dust/PM2.5 Sensor Sensitivity High High Normal* Normal* Hold down for about 5 seconds and when a short beep sounds, press while pressing •...
  • Page 14: Maintenance

    Maintenance WARNING Maintenance Before cleaning and maintenance work, make sure to unplug the unit. (An electric shock or injury may result) Outfl ow grille Wipe Wash/Rinse When dirt becomes an issue Removing • Wipe up dirt with a soft damp cloth and rinse with water.
  • Page 15 Maintenance WARNING • Do not use petrol, benzine, thinner, polishing compound, paraffin, alcohol, etc. (An electric shock, fire, or cracking may result) • Do not wash the main body of the unit with water. (An electric shock, fire, or malfunctioning/breakage may result) Deodorising filter unit When concerned about odours or dirt Removing...
  • Page 16: Replacing The Streamer Unit

    Maintenance WARNING Maintenance Before cleaning and maintenance work, make sure to unplug the unit. (An electric shock or injury may result) Replacing the Streamer Unit If the streamer lamp blinks The streamer unit will not need to be replaced. However, depending on where the unit is used (places where oils are present, or dust and humidity is abundant, or sprays and chemical agents are used, etc.) replacement may become necessary.
  • Page 17: Separately Sold Parts

    Maintenance Separately Sold Parts Contact the place of purchase. Replacement part Dust collection filter (electrostatic HEPA filter) ( 1 piece Model: KAFP080B4E • Replace about every 10 years. • Catches dust and pollen. • Failure to clean parts properly could result in: •...
  • Page 18: About The Indicator Lamps

    Troubleshooting About the Indicator Lamps Operating/Indicator panel Check the indicator lamps and respond as indicated below. Indicator lamp Cause/Solution Odour sensor lamp is blinking. This lamp blinks if the deodorising filter unit has become detached or is not attached properly. ...
  • Page 19: Faqs

    Troubleshooting FAQs Please check the following before contacting us. Q: The dust/PM2.5 sensor seems to have poor sensitivity... Perform periodic cleaning of the dust/PM2.5 sensor as dirt on its lens can lead to poor sensitivity. ►Page 13 In addition, the response time of the dust/PM2.5 sensor varies depending on room size.
  • Page 20: Troubleshooting

    Troubleshooting Troubleshooting „ Before making an inquiry or a request for repair, please check the following. If the problem persists, contact the place of purchase. „ In the event of malfunction during operation If the indicator lamps light up abnormally, or become inoperable, due to a lightning strike etc., remove the power supply plug, wait at least 5 seconds then reinsert the power supply plug and turn the unit on again.
  • Page 21 Troubleshooting Phenomenon Check points All the FAN lamps ( (Quiet), • Are the pre-fi lter, outfl ow grille, and dust collection fi lter attached? These lamps may blink if the unit is operated without a part attached. (Low), (Standard), and (Turbo)) blink together [If one or more parts are not attached]...
  • Page 22 Troubleshooting Troubleshooting „ Air purifying function Phenomenon Check points Air purifying capacity is reduced • Is the unit positioned in a place where airfl ow cannot reach or surrounded by obstacles?  Choose a position that is obstacle-free and from where airfl ow can reach all areas of the room.
  • Page 23: Specifications

    Troubleshooting Specifications Model name MC40UVM6 Power supply Single phase 50Hz 220-240V / 60Hz 220-230V Air Purifying Operation mode Turbo Standard Quiet Power consumption (W) Operating sound (dB) Airflow rate (m³/h) Coverage area (m²) External dimensions (mm) 500(H)× 270(W)× 270(D) Weight (kg) Power supply cord length (m) •...
  • Page 24 The bar code is a manufacturing code. The two-dimensional bar code is a manufacturing code. 3P484757-1D M16B358C (1812) HT...