Chapter 4
Connect the Management Interfaces and Perform Initial System Configuration
3.
DETAILED STEPS
Plug the Ethernet cable provided (with attached RJ-45 connector) into the Mng 1 port on the front panel
Step 1
of the SCE 2000.
Connect the other end of the Ethernet cable into your management network.
Step 2
The Link LED on the SCE 2000 management port should light up.
Step 3
Test connectivity. From the host that you intend to use for remote management, ping to the SCE 2000 by
typing pingand the SCE 2000 IP address, and pressing Enter (see the example, below).
This verifies that an active connection exists between the specified station and the management port.

EXAMPLE:

The following example displays a typical ping response where the target IP address is 10.1.1.201.
C:\>ping 10.1.1.201
pinging 10.1.1.201 ...
PING 10.1.1.201: 56 data bytes
64 bytes from host (10.1.1.201): icmp_seq=0. time=0. ms
64 bytes from host (10.1.1.201): icmp_seq=1. time=0. ms
64 bytes from host (10.1.1.201): icmp_seq=2. time=0. ms
64 bytes from host (10.1.1.201): icmp_seq=3. time=0. ms
----10.1.1.201 PING Statistics----
4 packets transmitted, 4 packets received, 0% packet loss
round-trip (ms) min/avg/max = 0/0/0
OL-7820-06
Test connectivity. From the host that you intend to use for remote management, ping to the SCE 2000
by typing pingand the SCE 2000 IP address, and pressing Enter (see the example, below).
Connect the Management Interface
Cisco SCE 2000 4xGBE Quick Start Guide
4-27

Advertisement

Table of Contents
loading

Table of Contents