Summary of Contents for SR Instruments SR Scales SR565i-H

  • Page 1 Model SR565i-H Bariatric Stand-On Scale Operating and Service Manual Part No. MAN565i-H__MICROBAN_180104 Page 1 of 20 by S Instruments, Inc. Bariatric Stand-On Scale Operating and Service Manual SInstruments, Inc. 600 Young Street, Tonawanda, NY 14150 Tel: 716-693-5977 Fax: 716-693-5854 URL: www.srscales.com Copyright 2018 SInstruments, Inc.
  • Page 2: Table Of Contents

    Model SR565i-H Bariatric Stand-On Scale Operating and Service Manual Part No. MAN565i-H__MICROBAN_180104 Page 2 of 20 TABLE OF CONTENTS TABLE OF FIGURES ......................... 2 PACKING CHECKLIST ......................3 ASSEMBLY ..........................4 REPLACEMENT PARTS AND ACCESSORIES ..............6 SYSTEM DESCRIPTION AND INTENDED USE ..............6 MAINTENANCE AND CLEANING ..................
  • Page 3: Packing Checklist

    Model SR565i-H Bariatric Stand-On Scale Operating and Service Manual Part No. MAN565i-H__MICROBAN_180104 Page 3 of 20 PACKING CHECKLIST  DESCRIPTION QUANTITY Box 1 BASE ASSEMBLY 1 ea MAST ASSEMBLY with DISPLAY and HEIGHT BAR 1 ea DISPLAY UNIT WITH CABLE 1 ea PACKAGE OF SIX (6) “D”...
  • Page 4: Assembly

    Model SR565i-H Bariatric Stand-On Scale Operating and Service Manual Part No. MAN565i-H__MICROBAN_180104 Page 4 of 20 ASSEMBLY PART NAME Mast Assembly Base Assembly Height Bar 3/8-16 Screws Display Unit Display Cable Connector Printer (optional) Printer Mounting Bracket (optional) Printer Cable (optional) Cable STEP 1: Unpack the scale system and check parts...
  • Page 5: Figure 3: Printer Mast Bracket

    Model SR565i-H Bariatric Stand-On Scale Operating and Service Manual Part No. MAN565i-H__MICROBAN_180104 Page 5 of 20 ASSEMBLY Cont’d STEP 6: Attach the Display Cable Connector (6) to its mate in the Base Assembly. Slide the extra cable back up into the mast pipe. Install the six (6) “D”...
  • Page 6: Replacement Parts And Accessories

    Model SR565i-H Bariatric Stand-On Scale Operating and Service Manual Part No. MAN565i-H__MICROBAN_180104 Page 6 of 20 REPLACEMENT PARTS and ACCESSORIES Part # Description SR8220 Printer Kit (optional; contains all printer parts listed below) FRAP1300 Printer FRAP13900BR-01 Printer Mounting Bracket SE8294 Printer Cable FRAP1300BP01 Rechargeable Battery Pack...
  • Page 7: Maintenance And Cleaning

    Model SR565i-H Bariatric Stand-On Scale Operating and Service Manual Part No. MAN565i-H__MICROBAN_180104 Page 7 of 20 MICROBAN ANTIMICROBIAL PROTECTION Microban® antimicrobial technology has been added to help reduce the growth of bacteria as part of a medical center's approach to creating a cleaner healthcare environment. For more information, visit https://www.microban.com/sr-scales MAINTENANCE and CLEANING...
  • Page 8: Specifications

    Model SR565i-H Bariatric Stand-On Scale Operating and Service Manual Part No. MAN565i-H__MICROBAN_180104 Page 8 of 20 SPECIFICATIONS MAXIMUM WEIGHT CAPACITY 1000 lb or 454 kg PLATFORM SIZE 18 in x 20 in (46 cm x 51 cm) Telescoping gauge – 43 in to 78 in INTEGRATED HEIGHT GAUGE 16-Character Dot Matrix LCD DISPLAY TYPE...
  • Page 9: Button Functions

    Model SR565i-H Bariatric Stand-On Scale Operating and Service Manual Part No. MAN565i-H__MICROBAN_180104 Page 9 of 20 BUTTON FUNCTIONS Figure 5: Button Display ZERO / WEIGH Press and hold to zero. The display will read “WT = 0.0 Lb”. This is used to zero the system before placing the patient on the scale system.
  • Page 10: Basic System Operation

    Model SR565i-H Bariatric Stand-On Scale Operating and Service Manual Part No. MAN565i-H__MICROBAN_180104 Page 10 of 20 BUTTON FUNCTIONS cont’d MENU Press Menu to edit setup. Setting the UNITS: Use UP or DOWN arrow buttons to select “Lb” or “Kg”. Press ENTER to save changes.
  • Page 11 Model SR565i-H Bariatric Stand-On Scale Operating and Service Manual Part No. MAN565i-H__MICROBAN_180104 Page 11 of 20 BASIC SYSTEM OPERATION cont’d WEIGHING Position the patient on the scale. Press the ZERO/WEIGH button. The weight stable indicator “ ” flashes on the display. When the weight is stable, the weight stable indicator remains solid.
  • Page 12: Battery Replacement

    Model SR565i-H Bariatric Stand-On Scale Operating and Service Manual Part No. MAN565i-H__MICROBAN_180104 Page 12 of 20 BATTERY REPLACEMENT WARNING DO NOT remove batteries while scale is on. Allow scale to shut down naturally thru timing out. This prevents possible voltage drain on the printed circuit board coin battery.
  • Page 13: Theory Of Operation

    Page 13 of 20 THEORY OF OPERATION SR Instruments patient weighing systems are digital scales. Strain-gauge force cells convert the force of an applied weight into an analog signal. This signal is amplified by an operational amplifier and converted to a digital signal by an on-chip analog to digital converter. The digital signal is filtered, converted to appropriate units, and displayed on the liquid crystal display.
  • Page 14: Calibration

    Model SR565i-H Bariatric Stand-On Scale Operating and Service Manual Part No. MAN565i-H__MICROBAN_180104 Page 14 of 20 CALIBRATION NOTE: Ensure that nothing is in contact with the scale system during this procedure. Remove hands from the system when noting the displayed calibration results. CHECKING CALIBRATION CALIBRATION STEP 1: Select two (2) known calibrated weights, traceable to...
  • Page 15 Model SR565i-H Bariatric Stand-On Scale Operating and Service Manual Part No. MAN565i-H__MICROBAN_180104 Page 15 of 20 CALIBRATION cont’d CAUTION The integrated circuits and semiconductors on the printed circuit boards may be damaged by electrostatic discharge (ESD). Be sure to use proper handling precautions at all times. SETTING CALIBRATION NOTE: Ensure that nothing is in contact with the scale system during this procedure.
  • Page 16: Configuring Send Button

    Electronic Medical Records (EMR) / Electronic Health Records (EHR) technology is supported by the i-series scales from SR Instruments. The EMR/ EHR software is not included with scale. There are many different EMR/ EHR software available and the connectivity of the scale to the software requires the services of a professional.
  • Page 17: Troubleshooting

    Model SR565i-H Bariatric Stand-On Scale Operating and Service Manual Part No. MAN565i-H__MICROBAN_180104 Page 17 of 20 TROUBLESHOOTING SYMPTOM REASON/CORRECTIVE ACTION Press the “WEIGH” button or remove one battery. The characters only appear on half of the Wait five seconds, then re-install the battery and try display.
  • Page 18: Warranty

    SR Instruments, Inc.’s part, and it neither assumes nor authorizes any other person to assume for SR Instruments, Inc. any other liabilities in connection with the sale of said articles. In no event shall SR Instruments, Inc.
  • Page 19 Model SR565i-H Bariatric Stand-On Scale Operating and Service Manual Part No. MAN565i-H__MICROBAN_180104 Page 19 of 20 NOTES SInstruments, Inc. 600 Young Street, Tonawanda, NY 14150 Tel: 716-693-5977 Fax: 716-693-5854 URL: www.srscales.com Copyright 2018 SInstruments, Inc. email: sri@srinstruments.com...
  • Page 20 Model SR565i-H Bariatric Stand-On Scale Operating and Service Manual Part No. MAN565i-H__MICROBAN_180104 Page 20 of 20 by S Instruments, Inc. Precision & Technology in Perfect Balance ® SInstruments, Inc. 600 Young Street, Tonawanda, NY 14150 Tel: 716-693-5977 Fax: 716-693-5854 URL: www.srscales.com Copyright 2018 SInstruments, Inc.