Daewoo DWD-T120R Service Manual page 63

Drum washing machine
Table of Contents

Advertisement

• situation : PCB shows "E3".
cause)
countermeasures)
part name
checking results
FAN MOTOR
fan motor failure
Remarks) control times of each parts during dry process
parts
MOTOR
DRAIN MOTOR
FAN MOTOR
DRY HEATER
INLET VALVE
FAN MOTOR can not work.
Replace the Fan Motor.
repair method
1Disassemble Duct Cover As from Duct B As(Screw 5EA)
replace
fan motor
COVER AS
2Disassemble FAN AS From Duct Cover As (Fixed by 8,
Fixed By
8mm NUT
3Disassemble the FAN MOTOR (SCREW 3EA)
Control time
15 sec On, 5sec Off
Continous working
Continous working
95°C On, 105°C Off
30sec On, 5sec Off
59
disassemble process of Fan Motor
DUCT
or
10mm NUT)
or
COVER DUCT AS
Fixed By 10mm NUT