1-2.
Method of Coping with Shift Lens Error
1-2-1.
E:62:02 Abnormality of IC for Steadyshot
Identify the cause of the problem (lens or VC-1042 board), and replace the faulty lens or the VC-1042 board.
1-2-2.
E:62:11 Shift Lens Overheating (Pitch)
Start the Adjust Manual in the Adjust Station and execute the "Measure to E:62:11/12" on the SERVICE tab.
Then confirm that the shift lens moves. If it does not move, replace the lens block.
Identify the cause of the problem (lens or VC-1042 board), and replace the faulty lens or the VC-1042 board.
1-2-3.
E:62:12 Shift Lens Overheating (Yaw)
Start the Adjust Manual in the Adjust Station and execute the "Measure to E:62:11/12" on the SERVICE tab.
Then confirm that the shift lens moves. If it does not move, replace the lens block.
Identify the cause of the problem (lens or VC-1042 board), and replace the faulty lens or the VC-1042 board.
1-2-4.
E:62:20 Abnormality of Thermistor
Check the connection between the lens block and VC-1042 board.
Identify the cause of the problem (lens or VC-1042 board), and replace the faulty lens or the VC-1042 board.
FDR-AX40/FDR-AX53/FDR-AX55/FDR-AXP55
1-5